• Title/Summary/Keyword: X-선 형광분석

Search Result 155, Processing Time 0.744 seconds

Surface Coating Treatment of Phosphor Powder Using Atmospheric Pressure Dielectric Barrier Discharge Plasma (대기압 유전체배리어방전 플라즈마를 이용한 형광체 분말 코팅)

  • Jang, Doo Il;Ihm, Tae Heon;Trinh, Quang Hung;Jo, Jin Oh;Mok, Young Sun;Lee, Sang Baek;Ramos, Henry J.
    • Applied Chemistry for Engineering
    • /
    • v.25 no.5
    • /
    • pp.455-462
    • /
    • 2014
  • This work investigated the hydrophobic coating of silicate yellow phosphor powder in the form of divalent europium-activated strontium orthosilicate ($Sr_2SiO_4:Eu^{2+}$) by using an atmospheric pressure dielectric barrier discharge (DBD) plasma with argon as a carrier and hexamethyldisiloxane (HMDSO), toluene and n-hexane as precursors. After the plasma treatment of the phosphor powder, the lattice structure of orthosilicate was not altered, as confirmed by an X-ray diffractometer. The coated phosphor powder was characterized by scanning electron microscopy, fluorescence spectrophotometry and contact angle analysis (CAA). The CAA of the phosphor powder coated with the HMDSO precursor revealed that the water contact angle increased from $21.3^{\circ}$ to $139.5^{\circ}$ (max. $148.7^{\circ}$) and the glycerol contact angle from $55^{\circ}$ to $143.5^{\circ}$ (max. $145.3^{\circ}$) as a result of the hydrophobic coating, which indicated that hydrophobic layers were successfully formed on the phosphor powder surfaces. Further surface characterizations were performed by Fourier transform infrared spectroscopy and X-ray photoelectron spectrometry, which also evidenced the formation of hydrophobic coating layers. The phosphor coated with HMDSO exhibited a photoluminescence (PL) enhancement, but the use of toluene or n-hexane somewhat decreased the PL intensity. The results of this work suggest that the DBD plasma may be a viable method for the preparation of hydrophobic coating layer on phosphor powder.

Study on Constituent Minerals and Illitization Characteristics of Yeongdong Illite Ore (영동 일라이트 광체의 구성광물 및 일라이트화 특성 연구)

  • EunJi Baek;Yu Na Lee;Byeongyong Yu;Dongbok Shin;Youngseuk Keehm;Sun Young Park;Hyun Na Kim
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.36 no.1
    • /
    • pp.41-54
    • /
    • 2023
  • Illite is a common mineral that forms readily from feldspar and mica via hydrothermal alteration and exhibits various characteristics depending on the degree of hydrothermal alteration. To ensure continued mining of high-quality illite ore, it is crucial to understand the illitization. Thus, this study collected ores from two illite ore deposit and their surrounding alteration zones in Yeongdong-gun, Chungcheongbuk-do, a significant source of illite in the Republic of Korea, to determine the constituent mineral contents and textural characteristics. Polarized light microscopy analyses revealed that the illite ore deposit were highly illitized with little remaining textural characteristics of the parent mica schist, and only some quartz was present. The ore zone contained illite, muscovite, quartz, and feldspar, with illitization primarily occurring around feldspar and quartz. X-ray diffraction analyses identified that the content of illite/muscovite was approximately 50-75 wt.%, with a maximum of 75 wt.%. Additionally, X-ray fluorescence analyses indicated a linear increase in K2O content with increasing illite content, showing the highest correlation among the major components analyzed. It is suggested that the illite in the Yeongdong area results from feldspar and quartz alteration by hydrothermal fluids along the fault, with illitization of feldspar occurring before that of quartz. The results of this study are expected to contribute to the development of high-quality illite ore deposit in Yeongdong, Chungcheongbuk-do.

A Study on the Judgment of Fire Cause of Ballast for Fluorescent Lamp (형광등용 안정기의 화재원인 판정에 관한 연구)

  • 최충석;백동현
    • Fire Science and Engineering
    • /
    • v.14 no.3
    • /
    • pp.1-5
    • /
    • 2000
  • In this paper, we analyzed the fire hazard of the ballast for fluorescent lamp used as the indoor lighting. In the result of being analyzed the ballast wire by stereo microscope, many melting points were discovered, it was impossible to judge a cause with the naked eye. In the Thermal-deteriorated ballast wire, elongation structure disappeared at above $700^{\circ}$, and it only showed the enlarged appearance of the copper particle. On the metallurgical microscope of short wire, as it was confirmed the regulation of the columnar structure and the void growth at the center of boundary-face, we found that electrical short-circuit generated. Also, it was confirmed the melted part on the analysis using SEM(scanning electron microscope). Not only CuL and Cuk line that is composition factor of copper but also OK line was observed uniformly on the spectra analysis using EDX(energy dispersive x-ray spectroscopy). It means that oxygen took part in reaction at the recombination process.

  • PDF

Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus (X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향)

  • Lee, Hoo-Min;Yoon, Joon;Kim, Hyun-Ju
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.187-193
    • /
    • 2014
  • The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

The Pigment Analysis of 『Procession of the Ladies』 Mural painting from Gaemachong, Koguryo (고구려 개마총 『여인행렬도』의 안료분석)

  • Yun, Eunyoung;Kim, Yuran;Kang, Hyungtae
    • Conservation Science in Museum
    • /
    • v.12
    • /
    • pp.53-58
    • /
    • 2011
  • This study investigated ingredient of the pigment of wall painting piece of women parade of Gaemachong Goguryo that the National Museum of Korea kept. XRF, a non-destructive analyzer, was used to investigate ingredient of the pigment. At the analysis, not only cinnabar/ vermillion(HgS) but also hematiae(Fe2O3) was used to produce red, and carbon was done to produce black, and lead white was done to produce white. The face was painted by mixture of not only cinnabar/ vermillion but also hematiae: No coloring was done depending upon situation.

A Study on Chemical Composition and Firing Temperature of White Wares from the Guyre-2ri Kiln Sites, Wonju (원주 귀래2리 가마터 출토 백자의 화학조성과 소성온도 연구)

  • Lee, Byeong Hoon;So, Myoung-Gi
    • Journal of Conservation Science
    • /
    • v.30 no.3
    • /
    • pp.249-261
    • /
    • 2014
  • This study aims to examine production technique of white wares from the Guyre-2ri 1st and 2nd kiln sites, Wonju, Gangwon Province and characteristics of the used materials, and to find a correlation among materials of the excavated white wares. X-ray fluorescence sequential spectroscopy(XRF), X-ray diffraction(XRD), Dilatometer and Inductively coupled plasma mass spectrometry(ICP-MS), Inductively coupled plasma automic emission spectrometer(ICP-AES) were applied to determine the chemical composition, crystalline phase of samples, firing temperatures, trace elements and rare earth elements. White wares from the Guyre-2ri kiln sites contained high contents of coloring oxides and fluxes. Though firing temperature of each sample was different, they were mostly fired at a temperature below $1200^{\circ}C$ and some of them experienced a low temperature of $1000^{\circ}C{\pm}20^{\circ}C$ and a high temperature above $1200^{\circ}C$. When analyzing body crystalline phases of the white wares using the XRD method, quartz and mullite were extracted from all the samples, and the proportions were similar to each other. When analyzing the excavated white wares using the Seger formula, also, all the samples showed similar clay sources and production techniques. Moreover, the white wares were made of host rocks of the same geological origin, according to the result of rare earth elements analysis.

Spectmscopic and Magnetic Properties of Yanggiseok, Yeonok and Eumgiseok used as Mineral Medicine (광물성 한약으로 이용되는 양기석, 연옥,음기석의 분광학적 및 자기적 특성)

  • 김선옥;박맹언;정율필
    • Economic and Environmental Geology
    • /
    • v.35 no.4
    • /
    • pp.317-323
    • /
    • 2002
  • Mineral medicines are single or mixtures of minerals and rocks which have been used to treat disease. Recently, their application has been increased by emphasizing the physical properies of the medicines, in addition to their chemical properies. In this study, mineralogical, chemical, spectroscopic and magnetic properties were measured using X-ray diffraction analysis, X-ray fluorescence spectrometry, Ff-Infrared spectroscopy, nuclear magnetic resonance spectroscopy, mass magnetic susceptibility. Experiments were done using these properties to evaluate application of traditional mineral medicines such as Yanggiseok, Yeonok and Eumgiseok. Mineralogical study proves that Yanggiseok, generally known as tremolite, consists of actinolite. Yeonok for medical usage mostly consists of fine grained tremolite. Eumgiseok is mainly composed of vermiculite and minor kaolinite and halloysite. Yeonok and Yanggiseok, belong to the amphibole group among inosilicates and both have similar emission power properties. The intensity of emission power, calculated from FT-IR measurements, follows in the order of Yeonok, Yanggiseok and Eumgiseok at 40$^{\circ}$C and Yanggiseok, Yeonok and Eumgiseok in such order at 150$^{\circ}$C. As a result of NMR analysis after 20 days in distilled water, the three mineral medicines decreased in the following order; Eumgiseok, Yanggiseok and Yeonok. However, the same minerals decreased in the order of Eumgiseok, Yeonok and Yanggiseok after 80 days. In response temperature, magnetic susceptibility of Yanggiseok and Eumgiseok systematically increased by heating to 25$^{\circ}$C, 100$^{\circ}$C and 700$^{\circ}$C. Magnetic susceptibility of Yeonok shows a decreasing pattern due to heating.

A Study on the Comparison of Chloride Ion Quantification Methods for Magnesium-Aluminum (Mg-Al) Alloy Powder (마그네슘-알루미늄(Mg-Al) 합금 분말의 염소이온 정량법의 비교에 관한 연구)

  • Yunhwan, Kim;Youngson Choe
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.450-454
    • /
    • 2023
  • Chloride ions in the alloy powder used as flux in Flux Cored Arc Welding (FCAW) can cause pores on the bead surface of the welding metal to cause defects, or chloride remaining in the alloy powder can cause corrosion of the metal. Combustion-ion chromatography is mainly used to quantify the chloride ions in alloy powder, but there is a limitation in that the equipment is expensive and requires a high degree of expertise. Therefore, this study aims to find an easy and accurate quantification method in the field by comparing combustion-ion chromatography (C-IC), which is mainly used for chloride ion quantification of alloy powder, X-ray fluorescence analysis (XRF), and potentiometric titration. In this article, magnesium-aluminum alloy powder is applied to the quantification of chloride ions because it is most commonly used as flux. This study confirmed that potentiometric titration can be applied to the quantification of chloride ions in the alloy powder in the industry field.

Material Characteristics of White Wares from Yeongdong Province, Gangwon-do: Gangneung and Donghae Kiln Sites (강원 영동지역 백자의 재료과학적 특성 연구: 강릉 남양리 백자가마터와 동해 발한동2(사문동) 가마터를 중심으로)

  • Lee, Byeong Hoon;So, Myoung-Gi
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.181-192
    • /
    • 2015
  • This study aims to examine production technique of twelve white wares from the Gangneung Namyang-ri and Donghae Balhan-dong2(Samun-dong) kiln sites, Kangwon Province and characteristics of the used materials, and to find a correlation among materials of the excavated white wares. X-ray fluorescence sequential spectroscopy(XRF), X-ray diffraction(XRD), Dilatometer and Inductively coupled plasma mass spectrometry(ICP-MS), Inductively coupled plasma automic emission spectrometer(ICP-AES) were applied to determine the chemical composition, crystalline phase of samples, firing temperatures, trace elements and rare earth elements. When analyzing body crystalline phases of the white wares using the XRD method, quartz and mullite were extracted from all the samples. Though firing temperature of each sample was different, they were mostly fired at a temperature below $1200^{\circ}C$. Analyzing the excavated white wares using the Seger formula, compositional properties of white wares in Gangneung Namyang-ri kiln showed diffrently from the Donghae Balhan-dong2(Samun-dong) kiln. The body of white wares from Gangneung Namyang-ri kiln have higher raito of $RO_2$ and $RO+R_2O$ than of white wares from Donghae Balhan-dong2(Samun-dong) kiln site. The white wares from Gangneung Namyang-ri kiln and Donghae Balhan-dong2(Samun-dong) kiln were made of host rocks of the different geological origin, according to the result of rare earth elements analysis.