• Title/Summary/Keyword: X-선

Search Result 3,810, Processing Time 0.031 seconds

Derivation of the Effective Energy Calculation Formula of the X-ray Beam Generated by the CT Simulator (CT 모의치료장치에서 발생된 X-선 빔의 유효에너지 계산식 유도)

  • Kim, Jong-Eon;Lee, Sang-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.869-875
    • /
    • 2021
  • The purpose of this study is to derive a formula for calculating the effective energy of an X-ray beam generated by a CT simulator. Under 90, 120, and 140 kVp X-ray beams, the CT number calibration insert part of the AAPM CT performance phantom was scanned 5 times with a CT simulator. The CT numbers of polyethylene, polystyrene, water, nylon, polycarbonate, and acrylic were measured for each CT slice image. The average value of CT number measured under a single tube voltage and the linear attenuation coefficients corresponding to each photon energy calculated from the data of the National Institute of Standards and Technology were linearly fitted. Among the obtained correlation coefficients, the photon energy having the maximum value was determined as the effective energy. In this way, the effective energy of the X-ray beam generated at each tube voltage was determined. By linearly fitting the determined effective energies(y) and tube voltages(x), y=0.33026x+30.80263 as an effective energy calculation formula was induced.

The Manufacture of Digital X-ray Devices and Implementation of Image Processing Algorithm (디지털 X-ray 장치 제작 및 영상 처리 알고리즘 구현)

  • Kim, So-young;Park, Seung-woo;Lee, Dong-hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.195-201
    • /
    • 2020
  • This study studied scoliosis, one of the most common modern diseases caused by lifestyle patterns of office workers sitting in front of computers all day and modern people who use smart phones frequently. Scoliosis is a typical complication that takes more than 80% of the nation's total population at least once. X-ray are used to test for these complications. X-ray, a non-destructive testing method that allows scoliosis to be easily performed and filmed in various areas such as the chest, abdomen and bone without contrast agents or other instruments. We uses NI DAQ to miniaturize digital X-ray imaging devices and image intensifier in self-shielding housing with Vision Assistant for drawing lines to the top and the bottom of the spine to acquire angles, i.e. curvature in real-time. In this way, the research was conducted to see scoliosis patients and their condition easily and to help rapid treatment for solving the problem of posture correction in modern people.

Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator (의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발)

  • Kwak, Dong-Hoon;Lee, Sang-Heon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.495-498
    • /
    • 2018
  • In this paper, we propose an DAP system for dose evaluation of medical and industrial X-ray generator. Based on the DAP measurement technique using the Ion-Chamber, the proposed system can clearly measure the exposure radiation dose generated by the diagnostic X-ray apparatus. The hardware part of the DAP measures the amount of charge in the air that is captured by an X-ray. The high-speed processing algorithm part for cumulative radiation dose measurement through microcurrent measures the amount of charge captured by X-ray at a low implementation cost (power) with no input loss. The wired/wireless transmission/reception protocol part synchronized with the operation of the X-ray generator improves communication speed. The PC-based control program part for interlocking and aging measures the amount of X-ray generated in real time and enables measurement graphs and numerical value monitoring through PC GUI. As a result of evaluating the performance of the proposed system in an accredited testing laboratory, the measured values using DAP increased linearly in each energy band (30, 60, 100, 150 kV). In addition, since the standard deviation of the measured value at the point of 4 division was ${\pm}1.25%$, it was confirmed that the DAP showed uniform measurements regardless of location. It was confirmed that the normal operation was not less than ${\pm}4.2%$ of the international standard.

One-dimensional XRD-Pattern Calculations of Clay Minerals: I. Dioctahedral and Trioctahedral Fe-rich Smectites (粘土鑛物의 一次元的 X-線 回折圖形의 計算: I. Dioctahedral 과 Trioctahedral Fe-rich 스멕타이트)

  • Ahn, Jung-Ho
    • Journal of the Mineralogical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.11-21
    • /
    • 1991
  • XRD patterns of biedellite-nontronite and saponite-iron saponite series were investigated using one-dimensional pattern simulation method. Ethylene-glycolate smectites show stronger 002 and 003 reflections than hydrated specimens do. The intensities of the 002 and 003 reflections change systematically as a function of Fe enrichment in both types of smectites. The intensity ratio of 002/003 increases with increasing. Fe in both dioctahedral to the higher scattering factor of Fe than those of Al and Mg, and the scattering power of various smectites can be compared quantitatively by calculating the scattering factors of octahedral cations. Interlayer cations cause less effect on XRD profile than octahedral cations as Fe do. Although 001 reflections provide informations about the overall scattering power of the octahedral sheet, some ferrous dioctahedtal smectite cannot be distinguished unambiguously from trioctahedral smectites on the basis of XRD profile. Simulation showed that heterogeneous smectites exhibit 001 intensity distribution that is almost identical to that of homogeneous smectites having the average composition of heterogeneous ones. The broadening of 001 reflections may not be useful in evaluating the degree of heterogeneity of smectite unless other factors affecting the broadening are well known.

  • PDF

Mossbauer Spectra of the $\textrm{Cd}_{x}\textrm{Ni}_{1-x}\textrm{Fe}_{2}\textrm{O}_{4}$ ($\textrm{Cd}_{x}\textrm{Ni}_{1-x}\textrm{Fe}_{2}\textrm{O}_{4}$의 Mossbauer 스펙트럼)

  • Baek, Seung-Do
    • Korean Journal of Materials Research
    • /
    • v.7 no.7
    • /
    • pp.618-622
    • /
    • 1997
  • 상온에서 측정한 Cd$_{x}$Ni$_{1-x}$Fe$_{2}$O$_{4}$의 Mossbauer 스펙트럼은 조성비에 따라 x값이 0.4이하인 시료에서는 준강자성에 의한 여섯개의 공명 흡수선, x값이 0.5인 시료에서는 이완된 형태의 공명흡수선, 그리고 x값이 0.6시료인 상자성에 의한 두개의 공명 흡수선이 나타났다. Cd$_{x}$Ni$_{1-x}$Fe$_{2}$O$_{4}$의 x값이 0.4이하인 시료의 초미세 자기장(H$_{hf}$)과 x값이 0.6 이상인 시료의 사중극자 분열치 (Q.S.)는 Cd농도가 증가함에 따라 감소한다. 시료의자기적 성질에 따른 이성질체 이동치(I.S.)의 차이는 있으나, Ni와 Cd이온의 농도에 따른 뚜렷한 의존성은 나타나지 않았다.다.

  • PDF

A Study on Stereo Visualization of the X-ray Scanned Image Based on Dual-line Sensors (듀얼센서 기반 X-선 검색영상 스테레오 가시화 연구)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Park, Jong-Won;Lim, Yong-Gon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.2083-2090
    • /
    • 2010
  • This paper presents a 3-D visualization technique using stereo radioactive images to provide efficient inspection of fast moving cargo objects. The proposed technique can be used for such objects which CT or MRI cannot inspect due to restricted scan environment. Stereo radioactive images are acquired from a specially designed equipment which consists of a X-ray source, linear radioactive sensors, and a moving stage. Two radioactive sensors are installed so that rectified stereo X-ray images of objects are acquired. Using the stereo X-ray images, we run a matching algorithm to find the correspondences between the images and reconstruct 3-D shapes of real objects. The objects are put in a parallelepiped box to simulate cargo inspection. Three real objects are tested and reconstructed. Due to the inherent ambiguity in the stereo X-ray images, we reconstruct 3-D shapes of the edges of the objects. The experimental results show the proposed technique can provide efficient visualization for cargo inspection.

X-Ray Resonant Magnetic Scattering Study of Magnetic Structures and Magnetic Switching Mechanism in Magnetic Multilayers and Nanostructures (엑스선 공명 자기 산란을 이용한 자성 다층박막 및 나노 구조체의 자기 구조와 자기 스위칭 메커니즘의 연구)

  • Lee, Dong-Ryeol
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.4
    • /
    • pp.160-166
    • /
    • 2010
  • X-ray resonant magnetic scattering (XRMS) allows us to extract magnetic depth profiles in magnetic multilayers and magnetization distribution in magnetic nanostructures in element-specific manner using x-ray reflectivity and diffraction. XRMS is explained with a brief introduction and examples of magnetic structures and magnetic switching mechanism in magnetic multilayers and nanostructures.

Genotoxicological Safety Evaluation of X-ray Irradiated Four Foods (X-선 조사식품 4종의 유전독성학적 안전성 평가)

  • Jung, Da-Woon;Huang, Yu-Hua;Song, Beom-Seok;Byun, Myung-Woo;Kang, Il-Jun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.10
    • /
    • pp.1588-1593
    • /
    • 2014
  • This study evaluated the genotoxic effects of 30 kGy of X-ray irradiation to four foods (chicken, egg powder, dried green onion, and black pepper). In bacterial reversion assay with Salmonella Typhimurium TA98, TA100, TA1535, and TA1537, the X-ray irradiated foods did not show a significantly increased number of revertant colonies in the presence or absence of the S9 metabolic activation system. In chromosomal aberration tests with Chinese hamster ovary (CHO) cells, the X-ray irradiated foods showed no increase in the frequency of chromosomal aberrations. In in vivo mouse micronucleus assay, the X-ray irradiated foods did not show any increase in the frequency of polychromatic erythrocytes with micronuclei. These results indicate that 30 kGy of X-ray irradiation to four foods (chicken, egg powder, dried green onion, and black pepper) showed no genotoxic effects under these experimental conditions.

A Study of Scattered Radiation Effect on Digital Radiography Imaging System (디지털 방사선영상 시스템에서 산란선이 영상 품질에 미치는 영향)

  • Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.71-78
    • /
    • 2017
  • Scattered radiation is inherent phenomenon of x-ray, which occurs to the subject (or patient). Therefore it cannot be avoidable but also interacts as serious noise factor because the only meaningful information on x-ray radiography is primary x-ray photons. The purpose of this study was to quantify scattered radiation for various shooting parameters and to verify the effect of anti-scatter grid. We employed beam stopper method to characterize scatter to primary ratio. To evaluate effect on the projection images calculated contrast to noise ratio of given shooting parameters. From the experiments, we identified the scattered radiation increases in thicker patient and smaller air gap. Moreover, scattered radiation degraded contrast to noise ratio of the projection images. We find out that the anti-scatter grid rejected scattered radiation effectively, however there were not fewer than 100% of scatter to primary ratio in some shooting parameters. The results demonstrate that the scattered radiation was serious problem of medical x-ray system, we confirmed that the scattered radiation was not considerable factor of dig ital radiog raphy.