The Study on Clinical Conditions and Skin Dose of Upper-Gastrointestinal X-ray Fluoroscopy (위장 X선 투시검사에 따른 실태 및 선량에 관한 연구)

  • Kim, Sung-Chul;Ahn, Sung-Min;Jang, Sang-Sup
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.7-12
    • /
    • 2007
  • This study examined present conditions of upper-gastrointestinal X-ray fluoroscopy and patient skin dose. The authors elected 21 equipments to check the X-ray equipment and exposure factor of fluoroscopy & spot exposure in university hospitals, hospitals, and clinics where perform upper-gastrointestinal X-ray fluoroscopy more than five times every day in Incheon areas. The amount of patient's skin dose during upper-gastrointestinal X-ray fluoroscopy was measured by ionization chamber.

  • PDF

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

Perception of Risk and Using Status of Hand-Held Dental X-Ray Unit (이동형 치과 X선 발생장치 사용실태와 위험지각)

  • Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.442-447
    • /
    • 2014
  • The aim of this study was to analyze perception of risk and using status of hand-held dental x-ray unit among dental hygienists in metropolitan area. This research was based on perception of risk and using status of hand-held dental x-ray unit survey in 257 dental hygienists from July 7 to 31, 2014. Data were analyzed with t-test, one way ANOVA, and multivariable logistic regression analysis using SPSS Windows 21.0 program and significance level was set at p<0.05. The hand-held dental x-ray unit to cover all type patients was 24.8%. The 62.6% of patients and 81.3% of operator doesn't wear lead apron, the experience rate of radiation education was 40.1%. The average of risk perception was 3.08 points. The associated factors of risk perception were career, number of radiation exposure per day, and possession of fixed x-ray unit. The increased of accumulated dose when the occupationally exposed work continues, it is necessary to effort of defense against dental radiation.

지혜 깊어지는 건강_건강검진 이야기 - 몸 속 찍는 사진기 CT & MRI 나에게 맞는 검사는?

  • Lee, Eun-Jeong
    • 건강소식
    • /
    • v.35 no.9
    • /
    • pp.16-17
    • /
    • 2011
  • 원통형 장치가 달린 검사대에 눕는다. 검사대가 원통 안으로 이동하면 X선, 혹은 자기장이 발생해 검사를 진행한다. X선을 이용하는 CT검사는 5분남짓, 자기장을 이용하는 MRI검사는 30분 남짓 걸린다. 치료보다는 '진단'을 중시하는 요즘, CT나 MRI는 우리 몸 구석구석을 들여다보고 진단에 도움을 주는 일반적인 검사로 통하고 있다.

  • PDF

X-ray Radiation from Pulsed Discharge Plasma (펄스형 방전플라스마에서 발생하는 X선 측정)

  • Choi, Woon-Sang;Moon, Byeong-Yeon;Kwak, Ho-Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.311-315
    • /
    • 2006
  • We investigated X-ray radiated from the pulsed Plasma Focus device that translated from electric energy into electromagnetic wave by electric discharge. X-ray radiation is analysed by using pin photodiode and 0.5mm pinhole camera shielded by $25{\mu}m$ Be. The condition of X-ray radiation was that the discharging voltage was 15 kV and the working gas were 0.12 torr Argon. Reproducibility of X-ray radiation is investigated and X-ray temperature is calculated above 3keV.

  • PDF

Construction and Performance Evaluation of Digital Radiographic System (이동형 디지털 X선 촬영장치의 구축 및 성능평가)

  • Cho, Hyo-Min;Nam, So-Ra;Lee, Chang-Lae;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.144-148
    • /
    • 2007
  • Current digital radiography systems are rapidly glowing in clinical applications. The purpose of this study was to evaluate the characteristics of a mobile digital radiographic system. The performance of the mobile DR system was evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on a LISTEM Mobix-1000 generator and a Teleoptic PRA Alpha-R4000 detector. Imaging characteristics were measured for these two systems using the IEC-61267 defined RQA5 (kVp: 74, additional filtration: 21 mmAl) radiographic condition. The MTF at 10% was measured as 2.4 cycles/mm and the DQE(0) values for radiation exposure 0.19, 0.5, and 1.3 mR were measured as 54%, 55%, and 76%, respectively. The NPS curves gradually decreased at high spatial frequencies. This high DQE at low frequencies, may be useful for low frequency information. The results suggested that mobile DR system could be integrated with emergency ambulance system in teleradiologic imaging applications.

  • PDF

A Study on Radiation Beam Quality Set-up of Mammography Equipment and Average Glandular Dose (유방 촬영 장치의 국제 규격 Beam Quality 기준에 따른 평균 선량 평가에 관한 연구)

  • Park, Yoon-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.303-308
    • /
    • 2022
  • Mammography using X-rays is currently the most used for early diagnosis of breast cancer. As the frequency of use of X-ray devices increases, interest in radiation hazards caused by mammography is increasing. Therefore, in this study, in order to measure the exposure dose of the mammary gland in X-ray mammography that requires high contrast and high resolution, the international Atomic Energy Agency (IAEA) stipulates the international standards presented by IEC 62220-1-2: 2015. Based on the beam quality criteria of the recommendation, we tried to present a guideline for evaluating the average mammary gland dose. As a result, the average streamline dose value of the 4.5 cm PMMA phantom was 2.3 mGy at the maximum within the 30 kV range, and was evaluated to be 1.19 mGy based on 28 kV.

해외리포트 - X선 자유전자 레이저 시설 SACLA

  • 한국광학기기협회
    • The Optical Journal
    • /
    • s.142
    • /
    • pp.57-64
    • /
    • 2012
  • X선 자유전자 레이저(XFEL:X-ray Free Electron Laser)는 통상의 레이저와 달리 물질에 속박되어 있지 않은 자유전자를 이용해 레이저 증폭을 일으킨다. 특히 펨토초의 펄스형태, 완벽한 결맞음 및 고휘도 등의 특성으로 X선 실험과학분야의 새로운 시대를 예고하는 꿈의 광원장치로 불리고 있다. 일본의 이화학연구소(Rikagaku Kenkyusho) 산하 하리마연구소(Harima Institute)에는 X선 자유전자 레이저 시설인 SACLA(SPring-8 Angstrom Compact free electron Laser)가 존재하며, SACLA의 독특한 설계와 기술은 세계 곳곳에서 건설되고 있는 XFEL 시설의 가이드라인이 되고 있다. 이번호에서는 SACLA 특징, SACLA 위원회와 도달광원 성능, SACLA의 토폰 빔 라인과 광학계 등을 소개한다. 이 원고는 하리마연구소의 이시카와 테츠야(Tetsuya Ishikawa) 소장이 월간 OPTRONICS 2012년 8월호에 기고한 내용으로 그린광학의 유정훈 팀장이 번역에 도움을 주었다.

  • PDF

The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube (강내형 X선 튜브 온도 및 선량 분포 특성)

  • Cho, Sungho;Lee, Rena
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.262-266
    • /
    • 2013
  • A new concept of periapical radiography, intra oral x-ray tube and detector system is introduced. It is new system that a miniature x-ray tube is inserted into mouse and it acquired digital image using external detector. In this study, we have investigated temperature and dose distribution of insertional x-ray tube for periapical radiography. To analyze temperature characteristic of x-ray tube, we attached the thermocouple to surface of x-ray tube and we measured the temperature according to distance. Also, we measured the dose distribution of a miniature x-ray tube according to distance. As a result, temperature was constant to $27^{\circ}C$ over 2mm without cooling system, dose distribution of x-ray tube was 3.14 and 1.84mGy in 3 and 5cm, respectively. Therefore, the proposed x-ray system works in lower dose than conventional dental x-ray system. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.