• 제목/요약/키워드: Wrist band type

검색결과 13건 처리시간 0.019초

손목형 혈압계의 센서부 개선에 대한 연구 (Improvement of a sensor unit for wrist blood pressure monitor)

  • 구상준;권종원;박용만;;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.380-382
    • /
    • 2007
  • As the society changes more to the aging society in future, many healthcare product are developed and distributed more on the market. The digital wrist band tye blood pressure device for home use are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially. It is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement accuracy of blood pressure is not enough compared to the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design fa capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.

  • PDF

손목형 생체신호수집 장치에 대한 연구 (A Study on Wrist Band Type Vital Sign Acquisition Device)

  • 김희훈;김경호
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.857-861
    • /
    • 2016
  • In this study, we proposed a new method that can be measure ECG (Electrocardiography) and PPG (Photoplethysmography) in realtime on the site of the wrist for check the state of health in daily life. For convenience measurement of ECG the lead I method was used on the wrist, and omit the reference junction ECG I was measured in the right hand and the left hand of the potential difference. Then the measured electrocardiogram was amplified by the differential amplifier and the signals were passed HPF, LPF, and BPF filters. For removing the PPG's noise from the Motion artifact and temperature, we apply the reflective photoelectric volume pulse wave measurement method using green LED as a light source. The circuits was designed to be able to check the waveform using higher active amplification method at weak signals. For the validation of our device, the measured signals were compared with E2-KIT on same time. The results shows that the error does not exceed the maximum one, most of the data is confirmed to be issued Peak inspection of the same number.

CT Dicom 파일을 이용하여 제작한 3D Print 손목보호대용 Velcro band 고정위치의 유한요소해석(FEM) (Finite Element Analysis(fem) of The Fixed Position of the Velcro Band for the 3D Print Wrist Brace made using the Dicom File)

  • 최현우;서안나;이종민
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.585-590
    • /
    • 2021
  • 손목 보조기(Wrist brace)는 손목 외상 환자들에게 사용이 되고 있다. 최근 맞춤형 손목 보조기를 3D 프린팅 기술을 활용하여 제작하는 많은 연구가 진행되고 있다. 이러한 3D 프린팅 맞춤형 보조기는 개인마다 다른 형태 반영, 통기성 확보 등의 다양한 요소를 반영할 수 있는 장점이 있다. 본 논문에서는 3D 프린팅 맞춤형 손목 보조기 제작 시 고려되어야 하는 벨크로 밴드 숫자와 위치가 보조기에 미치는 스트레스를 분석하였다. 맞춤형 보조기를 위해 CT 영상 기반으로 자동설계 소프트웨어(Reconeasy 3D, Seeann Solution)를 사용하여 뼈, 피부 영역 3D 모델링을 수행하였다. 3D 피부 영역을 기반으로, 각 치료 목적에 맞도록 손목 보조기 디자인을 적용하였다. 그리고, 보조기의 탄성을 위해 TPU 소재를 사용하여 FDM 방식 3D 프린터로 손목 보조기를 제작하였다. 맞춤형 3D 프린팅 손목 보조기의 벨크로 밴드의 숫자와 위치에 따른 효용성 평가를 위해 보조기의 스트레스 분포를 유한요소법(FEM)으로 분석하였다. 본 연구에서 수행한 손목 보조기 유한요소 해석을 통해 보조기의 스트레스 분포를 확인하였고 보조기 제작과 벨크로 밴드의 숫자와 위치를 확인할 수 있었다. 이러한 실험 결과는 환자에게 양질의 치료를 제공하는데 도움이 될 것이다.

광전용적맥파를 이용한 요골동맥 산소포화도 측정 시스템의 연구 (A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography)

  • 김경호
    • 한국컴퓨터정보학회논문지
    • /
    • 제15권3호
    • /
    • pp.11-18
    • /
    • 2010
  • 본 연구에서는 광전용적맥파를 이용하여 요골동맥에서 맥박 및 산소포화도를 검출하였다. 반사형으로 고안된 디바이스를 이용하여 요골동맥에서의 반사광은 수신부를 통해 측정되고, 이 측정된 신호는 스위칭을 통해 각각 625nm, 940nm의 파장대역의 신호로 분리된다. 분리된 신호는 각각의 맥박신호처리회로를 통해 맥박데이터로 구현된다. 본 연구에서는 반사 방식으로 손목부근의 요골동맥을 측정하였기에 투과방식이 아닌 반사방식의 산소포화도 측정에 적합한 방법을 적용하여 결과를 얻었다. 얻어진 결과는 약 97%정도의 정확도로 산소포화도를 검출할 수 있었다. 또한, 정확한 신호를 얻기 위해서 요골동맥에 센서가 장착된 밴드를 이용하여 측정 하였으며, 고정이 되도록 압박을 하였다. 결과로서 손목밴드의 장착을 통해 움직임에 의한 측정위치에러를 방지할 수 있었으며, 이에 따른 정확도를 높일 수 있었다.

루어낚시 참여자의 손목 움직임 측정을 위한 스트레치 센서 개발 (The Development of Stretch Sensors for Measuring the Wrist Movements for People Using Fishing Lures)

  • 최윤성;박진희;김주용
    • 감성과학
    • /
    • 제25권3호
    • /
    • pp.77-90
    • /
    • 2022
  • 본 연구의 목적은 루어낚시 참여자의 손목 움직임 측정을 위한 스트레치 센서를 개발하는 것이다. 손목움직임 측정을 위해 스트레치 센서를 손목에 부착하여 배굴, 저굴 그리고 랜딩동작을 게이지율, 인장강도 그리고 신장회복률을 척도로 실험을 진행하였다. CNT 분산액을 이용한 전도성 센서를 개발하고 E-band에 동일한 조건으로 적용하였다. 함침을 각각 한 번, 두 번, 그리고 세 번한 같은 크기의 5종, 15가지 센서를 만능재료시험기(Dacell dn-fga Universal testing machine, UTM)를 활용해 게이지율(Gauge Factor)을 측정하였다. 두 번 함침한 센서가 게이지율이 가장 우수했으며, 게이지율과 인장강도가 높은 세 가지 센서로 프로토 타입을 제작하였다. 아두이노에 연결하여 동작테스트를 한 결과, 인장강도와 게이지율이 가장 높은 시료 1이 세 가지 동작에서 일정한 파장이 유지되었다. 시료 2,3은 배굴과 저굴에서는 일정한 파장을 나타내었지만, 랜딩동작에서는 신호 노이즈가 나타났다. 이는, 랜딩동작에서는 인장강도와, 게이지율에 따라 파장의 패턴이 다르게 나타나는 것을 알 수 있었다. 이와 같은 결과로 손목의 움직임 측정을 위한 스트레치 센서 제작시에 필요한 조건들을 유추할 수 있었다. 본 연구의 결과를 활용하여 루어낚시용 스마트 웨어러블 제품 개발에 응용이 가능할 것으로 사료된다.

노인을 위한 효과적인 시각 정보 디자인: 노인과 손목에 착용하는 보행 보조 장치의 상호 교류에 대한 연구 (Effective Design of Visual Information for the Elderly: A Study on the Interaction between Wrist Band Type Walking Aid Device and the Elderly)

  • 김아람;김혜미;정광민;김진우
    • 감성과학
    • /
    • 제20권2호
    • /
    • pp.11-22
    • /
    • 2017
  • 본 연구는 길 찾는 능력과 거리를 인식하는 능력이 떨어지고 많은 주의력에 어려움을 느끼는 노인을 위해 간헐적인 주의 집중만으로 보행 안내를 받을 수 있는 손목에 착용하는 보행 보조 장치를 개발하기 위해 기존의 촉각 기술을 활용한 보행 보조 기술에서 시각 정보를 활용할 수 있도록 촉각 정보에 병행하는 시각 정보인 화면 UI에 초점을 맞추었다. 기술 수요자인 65세 이상 노인 30명에게 스마트워치를 착용시키고 Wizard of Oz로 네 가지 화면 UI로 길을 찾아가도록 지시한 후 각 화면 UI에 대한 평가 및 사후 인터뷰를 진행하였다. 선호도 순위, 경로를 이탈한 사람의 수, 경로 이탈 횟수에 대해 정량적 분석을 실시하고, 사후 인터뷰를 통해 수집된 사용 경험에 근거해 새로운 이해를 얻고자 질적 연구 방법론인 grounded theory로 정성적 분석을 진행하였으며, 본 연구 결과를 바탕으로 모순적인 요구사항을 가진 노인의 손목시계형 보행 보조 장치 개발 및 후속 연구를 위한 시사점을 도출하였다.

A study on the smart band, technologies, and case studies for the vulnerable group. - The Digital Age and the Fourth Industrial Revolution.

  • YU, Kyoungsung;SHIN, Seung-Jung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권1호
    • /
    • pp.182-187
    • /
    • 2022
  • This study aims to study non-rechargeable wrist-type smart bands for those vulnerable to the digital environment. The transition to the digital age means improving the efficiency of human life and the convenience of management. In the digital age, it can be a very convenient infrastructure for the digital generation, but otherwise, it can cause inconvenience. COVID-19 is spreading non-face-to-face culture. The reality is that the vulnerable are complaining of discomfort in non-face-to-face culture. The core of the digital environment is smartphones. Digital life is spreading around smartphones. Technology that drives the digital environment is the core technology of the Fourth Industrial Revolution. The technologies are lot, big data, Blockchain, Smart Mobility, and AI. Related technologies based on these technologies include digital ID cards, digital keys, and nfc technologies. Non-rechargeable wrist-type smart bands based on related technologies can be conceptualized. Through these technologies, blind people can easily access books and manage their ID cards conveniently and efficiently. In particular, access authentication is required wherever you go due to COVID-19, which can be used as a useful tool for the elderly who feel uncomfortable using smartphones. It can also eliminate the inconvenience of the elderly finding or losing their keys.

The Development Model of a non-rechargeable wrist-type smart-band for the vulnerable group

  • YU, Kyoungsung;SHIN, Seung-Jung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권1호
    • /
    • pp.170-181
    • /
    • 2022
  • We live in a digital age. Smartphones are used by everyone from children to the elderly. And many smart devices are pouring out and changing our daily life a lot. However, even in the development of this digital age, there are some marginalized groups. There are also those who are reluctant to expose their information in the digital age. They have difficulty making reservations on their smartphones, using payment systems, logging into the site using various authentication and verification procedures, and entering and leaving buildings. We still carry most IDs, seals, certificates, etc. in physical form. Those who use smartphones are enjoying the convenience of the times. However, among the underprivileged, the desire to pass everything with only one device is growing. In this study, the most suitable smart band model was proposed by collecting the Delphi survey and the opinions of the general public. Future research is required to improve practical usability and utility by developing cheaper and more convenient models.

The Important Frequency Band Selection and Feature Vecotor Extraction System by an Evolutional Method

  • Yazama, Yuuki;Mitsukura, Yasue;Fukumi, Minoru;Akamatsu, Norio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2209-2212
    • /
    • 2003
  • In this paper, we propose the method to extract the important frequency bands from the EMG signal, and for generation of feature vector using the important frequency bands. The EMG signal is measured with 4 sensor and is recorded as 4 channel’s time series data. The same frequency bands from 4 channel’s frequency components are selected as the important frequency bands. The feature vector is calculated by the function formed using the combination of selected same important frequency bands. The EMG signals acquired from seven wrist motion type are recognized by changing into the feature vector formed. Then, the extraction and generation is performed by using the double combination of the genetic algorithm (GA) and the neural network (NN). Finally, in order to illustrate the effectiveness of the proposed method, computer simulations are done.

  • PDF

원자력 발전소 작업복의 착용만족도에 관한 연구 (A Study on the Satisfaction of Working Uniform on Nuclear Power Plant)

  • 김영희;조경숙
    • 한국의류산업학회지
    • /
    • 제18권5호
    • /
    • pp.668-676
    • /
    • 2016
  • The purposes of this study were to investigate the satisfaction of working uniform in Nuclear Power Plant and to suggest the improvement of dissatisfaction. 150 workers in control area of Nuclear Power Plant were participated in survey and 30 questionnaires were asked and subjective description was allowed. 65%/35% Poly/Rayon coverall type working uniform was investigated for this survey which had been wearing usually and basically in control area in Nuclear Power Plant. According to the results, respondents were most highly dissatisfied with the wearing convenience aspect of current coverall among any other aspects, like textile and management. In wearing convenience aspects, wrist and ankle opening band system, the design, number and placement of pocket, waist belt design, the width of sleeve and pants, and ADR opening system were dissatisfied and requested for improvement. In textiles aspects, weight, protection from radiation materials, prevention from static electricity, moisture absorption, ventilation and flexibility/elasticity were dissatisfied and requested for improvement. In management aspect, washing uniform and size variation were dissatisfied and requested for improvement. Therefore, for more comfortable human interfaced working uniform, wearing convenience system as well as textile and management system must be compensated and should be newly developed for improving worker comfort, mobility, and productivity.