• Title/Summary/Keyword: Wrist band type

Search Result 13, Processing Time 0.028 seconds

Improvement of a sensor unit for wrist blood pressure monitor (손목형 혈압계의 센서부 개선에 대한 연구)

  • Koo, Sang-Jun;Kwon, Jang-Wan;Park, Yong-Man;Ayuznara, Odgerel;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.380-382
    • /
    • 2007
  • As the society changes more to the aging society in future, many healthcare product are developed and distributed more on the market. The digital wrist band tye blood pressure device for home use are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially. It is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement accuracy of blood pressure is not enough compared to the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design fa capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.

  • PDF

A Study on Wrist Band Type Vital Sign Acquisition Device (손목형 생체신호수집 장치에 대한 연구)

  • Kim, Hee-Hoon;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.857-861
    • /
    • 2016
  • In this study, we proposed a new method that can be measure ECG (Electrocardiography) and PPG (Photoplethysmography) in realtime on the site of the wrist for check the state of health in daily life. For convenience measurement of ECG the lead I method was used on the wrist, and omit the reference junction ECG I was measured in the right hand and the left hand of the potential difference. Then the measured electrocardiogram was amplified by the differential amplifier and the signals were passed HPF, LPF, and BPF filters. For removing the PPG's noise from the Motion artifact and temperature, we apply the reflective photoelectric volume pulse wave measurement method using green LED as a light source. The circuits was designed to be able to check the waveform using higher active amplification method at weak signals. For the validation of our device, the measured signals were compared with E2-KIT on same time. The results shows that the error does not exceed the maximum one, most of the data is confirmed to be issued Peak inspection of the same number.

Finite Element Analysis(fem) of The Fixed Position of the Velcro Band for the 3D Print Wrist Brace made using the Dicom File (CT Dicom 파일을 이용하여 제작한 3D Print 손목보호대용 Velcro band 고정위치의 유한요소해석(FEM))

  • Choi, Hyeun-Woo;Seo, An-Na;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.585-590
    • /
    • 2021
  • Wrist braces are being used for patients with wrist trauma. Recently, many studies have been conducted to manufacture custom wrist braces using 3D printing technology. Such 3D printing customized orthosis has the advantage of reflecting various factors such as reflecting different shapes for each individual and securing breathability. In this paper, the stress on the orthosis by the number and position of Velcro bands that should be considered when manufacturing a 3D printing custom wrist brace was analyzed. For customized orthosis, 3D modeling of the bone and skin regions was performed using an automatic design software (Reconeasy 3D, Seeann Solution) based on CT images. Based on the 3D skin area, a wrist orthosis design was applied to suit each treatment purpose. And, for the elasticity of the brace, a wrist brace was manufactured with an FDM-type 3D printer using TPU material. To evaluate the effectiveness according to the number and position of the Velcro band of the custom 3D printed wrist brace, the stress distribution of the brace was analyzed by the finite element method (FEM). Through the finite element analysis of the wrist orthosis performed in this study, the stress distribution of the orthosis was confirmed, and the number and position of the orthosis production and Velcro bands could be confirmed. These experimental results will help provide quality treatment to patients.

A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography (광전용적맥파를 이용한 요골동맥 산소포화도 측정 시스템의 연구)

  • Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.3
    • /
    • pp.11-18
    • /
    • 2010
  • In this study, the pulse of radial artery and oxygen saturation are detected using photoelectric plethysmograph method. Using our device designed reflection type, we can detect the reflected light by radial artery and by switching circuit, we can also separate to 625nm band signal and 940nm band signals. The separated signals are converted as a pulse data by the pulse signal processing circuit. In this study, the reflection type of oxygen saturation calculation method is applied instead of the transmission type because of the reflection type sensor is used to measure the radial artery. As a result, we can detect about 97% accuracy of the oxygen saturation compare with the conventional method. For the accurate signals, the wrist band with sensor was designed and fixed on the radial artery. As a result, this wrist band type sensor was applicable to prevent position errors from motion artifact and could increase the accuracy during the measuring.

The Development of Stretch Sensors for Measuring the Wrist Movements for People Using Fishing Lures (루어낚시 참여자의 손목 움직임 측정을 위한 스트레치 센서 개발)

  • Choi, Yoon-Seung;Park, Jin-hee;Kim, Joo-yong
    • Science of Emotion and Sensibility
    • /
    • v.25 no.3
    • /
    • pp.77-90
    • /
    • 2022
  • This study seeks to develop a stretch sensor for measuring the wrist movements of people using fishing lures. In order to confirm wrist movement, a stretch sensor was attached to the wrist band, and measurements of the dorsiflexion, plantar flexion, and fishing landing motion were measured using a scale to gauge factor, tensile strength, and elongation recovery rate. A conductive sensor using CNT dispersion was developed and applied to the E-band under the same conditions. A total of 15 sensors of the same size and five types of impregnation once, twice, and three times each were used to measure the gauge factor using UTM. The sensor that was impregnated twice had the best gauge rate, and the prototypes were manufactured with three sensors with high gauge rates and tensile strength. The results of the operation test conducted by connecting to the Arduino showed that Sample 1, which had the highest tensile strength and gauge factor, had a stable graph wavelength in three operations. Samples 2 and 3 showed stable wavelengths in the dorsiflexion and the plantar flexion; however, signal noise appeared in the fishing landing motion. This showed stable wavelengths in the two motions, but the wavelengths of the graphs differ depending on the tensile strength and gauge factor in the fishing landing motion. As a result, it was possible to identify the conditions necessary for manufacturing a stretch sensor for measuring wrist movement. This study will contribute to the development of smart wearable products for lure fishing.

Effective Design of Visual Information for the Elderly: A Study on the Interaction between Wrist Band Type Walking Aid Device and the Elderly (노인을 위한 효과적인 시각 정보 디자인: 노인과 손목에 착용하는 보행 보조 장치의 상호 교류에 대한 연구)

  • Kim, A-Ram;Kim, Hye-Mi;Jeong, Kwang-Min;Kim, Jin-Woo
    • Science of Emotion and Sensibility
    • /
    • v.20 no.2
    • /
    • pp.11-22
    • /
    • 2017
  • For the elderly whose path-finding capability and distance perception abilities have been weakened, the study intends to provide UI design of a wrist type walking aid device which allows the elderly to receive both visual and haptic information that induces the elderly' occasional attention by utilizing currently available haptic technology. The study asked 30 the elderly older than 65 years old, target consumers of the technology, to wear a smart watch and find a path by following the directions provided by four different UI versions of Wizard of Oz. Then, the study has conducted post-experience interview. Quantitative analyses was performed their preference level, number of misguided participants and the number of deviations incurred. Based on the data collected, the study has applied grounded theory, a qualitative research methodology, in order to grasp new understanding about the research, and has consequently reached some significant implications for further research on wrist type walking aid device for the elderly, who show self-contradictory demands.

A study on the smart band, technologies, and case studies for the vulnerable group. - The Digital Age and the Fourth Industrial Revolution.

  • YU, Kyoungsung;SHIN, Seung-Jung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.182-187
    • /
    • 2022
  • This study aims to study non-rechargeable wrist-type smart bands for those vulnerable to the digital environment. The transition to the digital age means improving the efficiency of human life and the convenience of management. In the digital age, it can be a very convenient infrastructure for the digital generation, but otherwise, it can cause inconvenience. COVID-19 is spreading non-face-to-face culture. The reality is that the vulnerable are complaining of discomfort in non-face-to-face culture. The core of the digital environment is smartphones. Digital life is spreading around smartphones. Technology that drives the digital environment is the core technology of the Fourth Industrial Revolution. The technologies are lot, big data, Blockchain, Smart Mobility, and AI. Related technologies based on these technologies include digital ID cards, digital keys, and nfc technologies. Non-rechargeable wrist-type smart bands based on related technologies can be conceptualized. Through these technologies, blind people can easily access books and manage their ID cards conveniently and efficiently. In particular, access authentication is required wherever you go due to COVID-19, which can be used as a useful tool for the elderly who feel uncomfortable using smartphones. It can also eliminate the inconvenience of the elderly finding or losing their keys.

The Development Model of a non-rechargeable wrist-type smart-band for the vulnerable group

  • YU, Kyoungsung;SHIN, Seung-Jung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.170-181
    • /
    • 2022
  • We live in a digital age. Smartphones are used by everyone from children to the elderly. And many smart devices are pouring out and changing our daily life a lot. However, even in the development of this digital age, there are some marginalized groups. There are also those who are reluctant to expose their information in the digital age. They have difficulty making reservations on their smartphones, using payment systems, logging into the site using various authentication and verification procedures, and entering and leaving buildings. We still carry most IDs, seals, certificates, etc. in physical form. Those who use smartphones are enjoying the convenience of the times. However, among the underprivileged, the desire to pass everything with only one device is growing. In this study, the most suitable smart band model was proposed by collecting the Delphi survey and the opinions of the general public. Future research is required to improve practical usability and utility by developing cheaper and more convenient models.

The Important Frequency Band Selection and Feature Vecotor Extraction System by an Evolutional Method

  • Yazama, Yuuki;Mitsukura, Yasue;Fukumi, Minoru;Akamatsu, Norio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2209-2212
    • /
    • 2003
  • In this paper, we propose the method to extract the important frequency bands from the EMG signal, and for generation of feature vector using the important frequency bands. The EMG signal is measured with 4 sensor and is recorded as 4 channel’s time series data. The same frequency bands from 4 channel’s frequency components are selected as the important frequency bands. The feature vector is calculated by the function formed using the combination of selected same important frequency bands. The EMG signals acquired from seven wrist motion type are recognized by changing into the feature vector formed. Then, the extraction and generation is performed by using the double combination of the genetic algorithm (GA) and the neural network (NN). Finally, in order to illustrate the effectiveness of the proposed method, computer simulations are done.

  • PDF

A Study on the Satisfaction of Working Uniform on Nuclear Power Plant (원자력 발전소 작업복의 착용만족도에 관한 연구)

  • Kim, Younghee;Cho, Kyungsook
    • Fashion & Textile Research Journal
    • /
    • v.18 no.5
    • /
    • pp.668-676
    • /
    • 2016
  • The purposes of this study were to investigate the satisfaction of working uniform in Nuclear Power Plant and to suggest the improvement of dissatisfaction. 150 workers in control area of Nuclear Power Plant were participated in survey and 30 questionnaires were asked and subjective description was allowed. 65%/35% Poly/Rayon coverall type working uniform was investigated for this survey which had been wearing usually and basically in control area in Nuclear Power Plant. According to the results, respondents were most highly dissatisfied with the wearing convenience aspect of current coverall among any other aspects, like textile and management. In wearing convenience aspects, wrist and ankle opening band system, the design, number and placement of pocket, waist belt design, the width of sleeve and pants, and ADR opening system were dissatisfied and requested for improvement. In textiles aspects, weight, protection from radiation materials, prevention from static electricity, moisture absorption, ventilation and flexibility/elasticity were dissatisfied and requested for improvement. In management aspect, washing uniform and size variation were dissatisfied and requested for improvement. Therefore, for more comfortable human interfaced working uniform, wearing convenience system as well as textile and management system must be compensated and should be newly developed for improving worker comfort, mobility, and productivity.