• Title/Summary/Keyword: Working pressure

Search Result 1,329, Processing Time 0.033 seconds

Development of the 80-kW Test Tractor for Load Measurement of Agricultural Operations (농작업 부하 계측을 위한 80kW급 계측 트랙터 개발 및 검증)

  • Cho, Seung-Je;Kim, Jeong-Gil;Park, Jin-Sun;Kim, Yeon-Soo;Lee, Dongkeun
    • Journal of Drive and Control
    • /
    • v.19 no.4
    • /
    • pp.46-53
    • /
    • 2022
  • RIn this study, a test tractor that could measure various types of agricultural operational loads was developed, and its performance was verified. This tractor could be used to measure the load generated during agricultural work and convert the related data into a database. A test tractor was developed using an 80-kW-rated load tractor, and it could measure various types of field test data, such as engine torque and rpm, wheel torque, PTO(power take-off) torque, hexometer, IMU/INS sensor, steering angle sensor, hydraulic pressure, and flow sensor data. To verify the developed test tractor, a verification test using an agriculture rotavator was performed. The test conditions were L1, L2, and L3 based on the tractor's main and sub-transmission stages, and stages 1 and 2 were selected as the PTO. In a comparison of the analyzed test data, similar tendencies in the test results of this research and other research (Kim's research) were seen. Through this, the developed test tractor was verified. In the future, we plan to conduct research on the tractor developed in this study using various attached working machines.

Analysis of the Physical and Mechanical Properties of Injected High-Density Polyurethane from Laboratory Experiments and Field Tests (실내실험 및 현장실험을 통한 고밀도 폴리 우레탄 공법의 물리·역학적 특성 분석)

  • Choi, Junyoung;Kim, Daehyeon
    • The Journal of Engineering Geology
    • /
    • v.31 no.1
    • /
    • pp.83-101
    • /
    • 2021
  • The high-density polyurethane method uses the instantaneous expansion pressure of injected material to stabilize soft ground, allowing reinforcement, restoration, and construction to be carried out in suboptimal ground conditions. Under normal and, even poor conditions, the method is easily applied because the working time is very short. The method is environmentally friendly and results have excellent durability. The purpose of this study was to verify the physical and mechanical properties of high-density polyurethane in the ground. Initial testing of strength, direct shear, and soil environment stability was followed by testing for permeability in order to address environmental concerns. The results of the experiments showed that the internal friction angle was about twice as high and the adhesion was about 2.5 to 3.5 times higher than for dense and hard clay, and that the permeability factor was significantly lower compared with the existing grouting method, within the range of 1.0 × 10-5.

Mechanical behavior of coiled tubing over wellhead and analysis of its effect on downhole buckling

  • Zhao, Le;Gao, Mingzhong;Li, Cunbao;Xian, Linyun
    • Steel and Composite Structures
    • /
    • v.44 no.2
    • /
    • pp.199-210
    • /
    • 2022
  • This study build finite element analysis (FEA) models describing the bending events of coiled tubing (CT) at the wellhead and trips into the hole, accurately provide the state of stress and strain while the CT is in service. The bending moment and axial force history curves are used as loads and boundary conditions in the diametrical growth models to ensure consistency with the actual working conditions in field operations. The simulation diametrical growth results in this study are more accurate and reasonable. Analysis the factors influencing fatigue and diametrical growth shows that the internal pressure has a first-order influence on fatigue, followed by the radius of the guide arch, reel and the CT diameter. As the number of trip cycles increase, fatigue damage, residual stress and strain cumulatively increase, until CT failure occurs. Significant residual stresses remain in the CT cross-section, and the CT exhibits a residual curvature, the initial residual bending configuration of CT under wellbore constraints, after running into the hole, is sinusoidal. The residual stresses and residual bending configuration significantly decrease the buckling load, making the buckling and buckling release of CT in the downhole an elastic-plastic process, exacerbating the helical lockup. The conclusions drawn in this study will improve CT models and contribute to the operational and economic success of CT services.

Minimum cost design for circular isolated footings with eccentric column taking into account that the surface in contact with the ground works partially in compression

  • Inocencio Luevanos-Soto;Arnulfo Luevanos-Rojas;Victor Manuel Moreno-Landeros;Griselda Santiago-Hurtado
    • Coupled systems mechanics
    • /
    • v.13 no.4
    • /
    • pp.311-335
    • /
    • 2024
  • This work aims to show a model to estimate the minimum cost (Thickness and area of steel in X and Y directions) for design a circular isolated footing with eccentric column that considers that the surface in contact with the ground works partially under compression. The formulation is shown by integration to find the moments, the bending shears and the punching shear using the pressure volume under the footing. Some researchers show the minimum cost design for circular isolated footings for an eccentric column assuming that the contact area works completely in compression, others consider the contact surface with the ground working partially in compression for a column in the center of the base. Three numerical examples are developed to obtain the complete design, which are: Example 1 for a column in the center of the base,Example 2 for a column at a distance of 1.50 m from the center of the base in the X direction, Example 3 for a column at a distance of 1.50 m from the center of the base in both directions. Also, a comparison of the new model against the model proposed by other authors is presented. The comparison shows that the new model generates a great saving of up to 43.74% for minimum area and 48.44% for minimum cost design in a column located in the center of the base, and when the column is located at a distance of radius/2 starting from the center of the base in the X direction generates great savings of up to 45.24% for minimum area and 31.80% for minimum cost design. Therefore, it is advisable to use the model presented in this study.

The Effect of VDT Work on Vision and Eye Symptoms among Workers in a TV Manufacturing Plant (텔레비젼(TV)생산업체 근로자들의 영상단말기(VDT)작업이 시력과 안증상에 미치는 영향)

  • Woo, Kuck-Hyeun;Choi, Gwang-Seo;Jung, Young-Yeon;Han, Gu-Wung;Park, Jung-Han;Lee, Jong-Hyeob
    • Journal of Preventive Medicine and Public Health
    • /
    • v.25 no.3 s.39
    • /
    • pp.247-268
    • /
    • 1992
  • This study was conducted to evaluate the effect of VDT work on eyes and vision among workers in a TV manufacturing plant. The study subjects consisted of 264 screen workers and 74 non-screen workers who were less than 40 years old male and had no history of opthalmic diseases such as corneal opacities, trauma, keratitis, etc and whose visual acuity on pre-employment health examination by Han's test chart was 1.0 or above. The screen workers were divided into two groups by actual time for screen work in a day : Group I, 60 workers, lesser than 4 hours a day and group II, 204 workers, more than 4 hours a day. From July to October 1992 a questionnaire was administered to all the study subjects for the general charateristics and subjective eye symptoms after which the opthalmologic tests such as visual acuity, spherical equivalent, lacrimal function, ocular pressure, slit lamp test, fundoscopy were conducted by one opthalmologist. The proportion of workers whose present visual acuity was decreased more than 0.15 in comparison with that on the pre-employment health examination by Han's test chart was 20.6% in Group II. 15.0% in Group I and 14.9% in non-screen workers. However, the differences in proportion were not statistically significant. The proportion of workers with decreased visual acuity was not associated with the age, working duration, use of magnifying glass and type of shift work (independent variables) in all of the three groups. However, screen workers working under poor illumination had a higher proportion of persons with decreased visual acuity than those working under adequate illumination (P<0.05) . The proportion of workers whose near vision was decreased was 27.5% in Group II, 18.3% in Group I, and 28.4% in non-screen workers and these differences in proportion were not statistically significant. Changes of near vision were not associated with 4 independent variables in all of the three groups. Six out of seven subjective eye symptoms except tearing were more common in Group I than in non-screen workers and more common in Group II than in Group I (P<0.01). Mean of the total scores for seven subjective symptoms of each worker(2 points for always, 1 point for sometimes, 0 point for never) was not significantly different between workers with decreased visual acuity and workers with no vision change. However, mean of the total scores for Group II was higher than those for the Group I and non-screen workers (P<0.01). Total eye symptom scores were significantly correlated with the grade of screen work, use of magnifying glass, and type of shift work. There was no independent variable which was correlated with the difference in visual acuity between the pre-employment health examination and the present state, the difference between far and near visions, lacrimal function, ocular pressure, and spherical equivalent. Multiple linear regression analysis for the subjective eye symptom scores revealed a positive linear relationship with actual time for screen work and shift work(P<0.01). In this study it was not observed that the VDT work decreased visual acuity but it induces subjective eye symptoms such as eye fatigue, blurred vision, ocular discomfort, etc. Maintenance of adequate illumination in the work place and control of excessive VDT work are recommended to prevent such eye symptoms.

  • PDF

Thermophysiological Responses of Wearing Safety Hat for Working at a Hot Environment (서열환경하에서 안전모 착용시의 인체생리학적 반응)

  • 박소진;김희은
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.1
    • /
    • pp.74-82
    • /
    • 2002
  • The present study is aimed to investigate the effect of the safety hat on the balance of body temperature by observation of the physiological response under hot working environment. The experiment was carried out in a climate chamber of 3$0^{\circ}C$, 50%RH for 70 minutes. To compare the two kinds of safety hat, 5 healthy male subjects worn safety hat without hole (called 'without hole') or safety hat with hole (called 'with hole') according to a randomized cross-over design. The main results of this study are as fellows: Rectal temperature and heart rate were significantly lower level in 'with hole'than in 'without hole'. The mean skin temperature was significantly higher in 'without hole'than in 'with hole'. Blood pressure were significantly low in 'with hole'. Sweat rate which was measured by weight loss before and after experiment was higher in 'without hole'. In subjective ratings, subjects replied more hot, more uncomfortable and more wet, they felt more fatigue in condition of 'without hole'. Work ability which was measured by a grip strength dynamometer was higher in 'with hole'. Safety hat which can be used for safety of the brain in work place is meaningful device of behavioral thermoregulatory response under the hot working environment. The safety hat which is designed for proper ventilation and hygiene can maintain the homeostasis of body temperature by releasing body temperature efficiently.

Management and Supporting System on the Occupational Health Nursing Services Provided in Group Occupational Health Agencies of Korea (소규모 사업장 보건관리대행기관의 간호업무 운영관리 지원체계)

  • Yoo, Kyung-Hae
    • Korean Journal of Occupational Health Nursing
    • /
    • v.8 no.2
    • /
    • pp.193-211
    • /
    • 1999
  • This study was carried out to investigate the management and support system affecting to the occupational health nursing services(OHNS) provided in group occupational health agencies(GOHA). Questionnaire was developed and distributed to 82 nurses who were working in GOHA and who agreed to participate in the survey. The results were as follow: 1. OH nurses responded were mostly in the age of twenty to thirties(89%), married(73.7%), technical college graduates(88.9%), worked in hospital(85.4%) and participated more than 1 year in group occupational health services (96.3%). 2. Fifty eight point four percent of the OH nurses worked in number of workplace more than 30 to less than 60 in the OHNS form. The figure of workplaces undertaken by nurses was ranged greatly from 9 to more than 100. Number of employees who cared by nurses were mostly under 5,000 peoples in 93.3%. The types of industry was mostly manufacturing and located in the order of factory complex area, suburban, urban and others. 3. Most OH nurses(87.8%) were fully involved in the OHNS for the SSE. Their working days to visit SSE was 5 days per week(77.8%) and one day in the GOHA at 41.3%. 4. The OH documents using by nurses were found in more than 23 different types. However, they were largely summarized in the types of 'Workplace Health Management Card', 'Personal Health Counselling Card', 'Daily Health Management Report', 'Visiting List of Workplace' and 'Sick Employee List'. 5. The items of laboratory test provided by GOHA were mostly achieved in the purpose of basic health examination. They were used to be the blood pressure check(98.8%), blood sugar test (98.8%), urine sugar and protein(91.4%), SGOT and SGPT(85.3% each), cholesterol (82.9%), hepa vaccine immunization(82.9%), r-GPT(81.7%), hemoglobin(79.3%) and triglyceride(75.5%). 6. The OH nurses(92.7%) followed the work pattern to visit the GOHA before and after small-scale enterprises(SSE) visit by car driven by nurses in 74.3%. They were payed by GOHA for transportation fees in certain amounts. However, nurse is the main person(75.0%) who covers up in case of traffic accident. If the GOHA has no transportation regulation for the formal workplace visit, data showed that nurses had been responsible to take charge(31.7%). 7. The personnel manager who takes in charge for nursing services was 'nurse' in 61.7% and 41.2% worked as the final decision maker related to nursing work. The OH nurses' opinions about factors affecting to the management were classified in the four areas such as 'Nature(Quality) of health professional'. 'Content of OHNS', 'Delivery system of the GOHS', and 'Others'. The factors were indicated highly in 'Authority as health professional', 'Level of perception of director on the OH' and 'Physical work condition for OHNS'. The things that this study suggests in the recommendation would be summarized in such as the management and supporting system working for SSE in the OHNS is necessary to reform thoroughly. The reconsidered aspects might be in the matters of number of workplaces undertaken by nurses, development of effectively practical health documents, preparation for guideline of the laboratory test in the workpleces, establishment of convenient and encouraging support system and cooperation between other health professionals with respect and skill.

  • PDF

Enhancement of the Working Capacity and Selectivity Factor of Calcium-Exchanged Y Zeolites for Carbon Dioxide Pressure Swing Adsorption (이산화탄소 압력순환흡착을 위한 칼슘 이온교환 Y 제올라이트의 작업용량과 선택계수 향상)

  • Kim, Moon Hyeon
    • Clean Technology
    • /
    • v.24 no.1
    • /
    • pp.41-49
    • /
    • 2018
  • Y zeolites with different extra-framework cations, such as $Na^+$, $N^+$, $Ca^{2+}$, and $Cu^{2+}$, with different charge and ionic radius have been investigated to greatly enhance a working capacity (W) of $CO_2$ adsorption at $25^{\circ}C$ and a $CO_2/CO$ selectivity factor (S). A sample of NaY with a very small amount of 0.012% $Ca^{2+}$ was fully reversible for seven times repeated $CO_2$ adsorption/desorption cycles, thereby forming no surface carbonates unlikely earlier reports. Although at pressures above 4 bar, 2.00% CaY, 1.60% CuY and 1.87% LiY all showed a $CO_2$ adsorption very similar to that measured for NaY, they gave a significant decrease in the adsorption at lower pressures, depending on the metal ion. At 0.5 ~ 2.5 bar, the extent of $CO_2$ adsorption was in the order NaY > 1.60% CuY > 2.00% CaY > 1.87% LiY. All the $Na^+-based$ metals-exchanged zeolites have a FAU (faujasite) framework and a Si/Al value near 2.6; thus, there is no discernible difference in the framework topology, framework chemical compositions, effective aperture size, and channel structure between the zeolite samples. Therefore, the distinctive behavior in the adsorption of $CO_2$ with a character as a weak Lewis acid is associated with the site basicity of the zeolites, and the interaction potentials of the cations. Different trend was shown for a CO adsorption due to weaker quadrupole interactions. Adsorption of $CO_2$ and CO on samples of CaY with 0.012 to 5.23% Ca disclosed a significant dependence on the Ca loading. The $CO_2$ adsorption increased when the cation exists up to ca. 0.05%, while it decreased at higher Ca amounts. However, values for both W and S could greatly increase as the bare zeolite is enriched by $Ca^{2+}$ ions. The 5.23% CaY had $W=2.37mmol\;g^{-1}$ and S = 4.37, and the former value was comparable to a benchmark reported in the literature.

The Characteristics Study of Vehicle Evaporative Emission and Performance according to the Bio-Fuel Application (바이오 연료 적용에 따른 차량 증발가스 및 성능특성 연구)

  • Noh, Kyeong-Ha;Lee, Min-Ho;Kim, Ki-Ho;Kim, Sin;Park, Cheon-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.874-882
    • /
    • 2017
  • As the interest on the air-pollution is gradually rising up at home and abroad, automotiv e and fuel researchers have been working on the exhaust emission reduction from vehicles through a lot of approaches, which consist of new engine design, innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research has brought forward three main issues : evaporative, performance, air pollution. In addition, researcher studied the environment problems of the bio-ethanol, bio-butanol, bio-ETBE (Ethyl Tertiary Butyl Ether), MTBE (Methyl Tert iary Butyl Ether) fuel contained in the fuel as octane number improver. The researchers have many dat a about the health effects of ingestion of octane number improver. However, the data support the con clusion that octane number improver is a potential human carcinogen at high doses. Based on the bio-fuel and octane number improver types (bio-ethanol, bio-butanol, bio-ETBE, MTBE), this paper dis cussed the influence of gasoline fuel properties on the evaporative emission characteristics. Also, this p aper assessed the acceleration and power performance of gasoline vehicle for the bio-fuel property. As a result of the experiment, it was found that all the test fuels meet the domestic exhaust gas standards, and as a result of measurement of the vapor pressure of the test fuels, the bio - ethanol : 15 kPa and the biobutanol : 1.6 kPa. thus when manufacturing E3 fuel, Increasing the biobutanol content reduces evaporation gas and vapor pressure. In addition, Similar accelerating and powering performance was shown for the type of biofuel and when bio-butanol and bio-ethanol were compared accelerated perf ormance was improved by about 3.9% and vehicle power by 0.8%.

Preparation of Pure CO2 Standard Gas from Calcium Carbonate for Stable Isotope Analysis (탄산칼슘을 이용한 이산화탄소 안정동위원소 표준시료 제작에 대한 연구)

  • Park, Mi-Kyung;Park, Sunyoung;Kang, Dong-Jin;Li, Shanlan;Kim, Jae-Yeon;Jo, Chun Ok;Kim, Jooil;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • The isotope ratios of $^{13}C/^{12}C$ and $^{18}O/^{16}O$ for a sample in a mass spectrometer are measured relative to those of a pure $CO_2$ reference gas (i.e., laboratory working standard). Thus, the calibration of a laboratory working standard gas to the international isotope scales (Pee Dee Belemnite (PDB) for ${\delta}^{13}C$ and Vienna Standard Mean Ocean Water (V-SMOW) for ${\delta}^{18}O$) is essential for comparisons between data sets obtained by other groups on other mass spectrometers. However, one often finds difficulties in getting well-calibrated standard gases, because of their production time and high price. Additional difficulty is that fractionation processes can occur inside the gas cylinder most likely due to pressure drop in long-term use. Therefore, studies on laboratory production of pure $CO_2$ isotope standard gas from stable solid calcium carbonate standard materials, have been performed. For this study, we propose a method to extract pure $CO_2$ gas without isotope fractionation from a solid calcium carbonate material. The method is similar to that suggested by Coplen et al., (1983), but is better optimized particularly to make a large amount of pure $CO_2$ gas from calcium carbonate material. The $CaCO_3$ releases $CO_2$ in reaction with 100% pure phosphoric acid at $25^{\circ}C$ in a custom designed, evacuated reaction vessel. Here we introduce optimal procedure, reaction conditions, and samples/reactants size for calcium carbonate-phosphoric acid reaction and also provide the details for extracting, purifying and collecting $CO_2$ gas out of the reaction vessel. The measurements for ${\delta}^{18}O$ and ${\delta}^{13}C$ of $CO_2$ were performed at Seoul National University using a stable isotope ratio mass spectrometer (VG Isotech, SIRA Series II) operated in dual-inlet mode. The entire analysis precisions for ${\delta}^{18}O$ and ${\delta}^{13}C$ were evaluated based on the standard deviations of multiple measurements on 15 separate samples of purified $CO_2$. The pure $CO_2$ samples were taken from 100-mg aliquots of a solid calcium carbonate (Solenhofen-ori $CaCO_3$) during 8-day experimental period. The multiple measurements yielded the $1{\sigma}$ precisions of ${\pm}0.01$‰ for ${\delta}^{13}C$ and ${\pm}0.05$‰ for ${\delta}^{18}O$, comparable to the internal instrumental precisions of SIRA. Therefore, we conclude the method proposed in this study can serve as a way to produce an accurate secondary and/or laboratory $CO_2$ standard gas. We hope this study helps resolve difficulties in placing a laboratory working standard onto the international isotope scales and does make accurate comparisons with other data sets from other groups.