• Title/Summary/Keyword: Working cast

Search Result 62, Processing Time 0.026 seconds

An Empirical Study on the Cost Finding of Dental Laboratory Products in a University Hospital (치과기공물(齒科技工物) 원가계산(原價計算)에 관(關)한 실증적(實證的) 연구(硏究))

  • Paek, Seok-Hyeon
    • Journal of Technologic Dentistry
    • /
    • v.16 no.1
    • /
    • pp.78-104
    • /
    • 1994
  • Under the fee for service schedule of Korean health insurance system, rational fee for dental laboratory products based on the cost is required to be formulated. The purpose of this study was to find actual cost of dental laboratory products in case of a University Hospital. Materials of this study were used as follows : 1. Balance sheet at Dec. 31, 1992 and profit and loss report of the year 1992 of the sample hospital 2. Performance report of dental laboratory department. 3. Purchasing and other accounting bills of dental laboratory materials. The following methods were used. 1. Actual cost finding of dental laboratory department was performed. 2. Work sampling methods were used for measuring standard working time by the process of working. 3. To porcelain fused to metal crown(non-precious), Relative value of the cost of dental laboratory products was calculated as 1.00. 4. Fee and cost of those products were compared on the basis of Relative values. The results of the study can be summarized as follow : 1. Overall, it took longs time than other items. to product denture-related items. 2. When several teeth are made in a time, average production time is much sorter than when one tooth is made in a time. 3. The relative price cost of Dicor cast crown and denture related items are higher than the criterion items. 4. The material cost occupies average 11% out of the total price cost, proportion of personnel expenses is average as 60.0%. 5. Some of the components consisting of the price cost are not reflected adequately in setting the level of the reimbursement price. 6. Relative values of dental laboratory products price cost are varied in the range from 0.05 to 2.83, overall, the reimbursement price of dental products appears not to reflect adequately the price cost. On the basis of this study results, the following ideas would be suggested : 1. Fee Schedule of dental laboratory products should be renovated in order to reflect their costs. 2. Dental laboratory product manufacturers should be enlarged for the economy of scale which may be useful for cost- containment. 3. Dental laboratory producters themselves are required to be standardiqed according to the categories of skill.

  • PDF

Gingival recontouring by provisional implant restoration for optimal emergence profile: report of two cases

  • Son, Mee-Kyoung;Jang, Hyun-Seon
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.6
    • /
    • pp.302-308
    • /
    • 2011
  • Purpose: The emergence profile concept of an implant restoration is one of the most important factors for the esthetics and health of peri-implant soft tissue. This paper reports on two cases of gingival recontouring by the fabrication of a provisional implant restoration to produce an optimal emergence profile of a definitive implant restoration. Methods: After the second surgery, a preliminary impression was taken to make a soft tissue working cast. A provisional crown was fabricated on the model. The soft tissue around the implant fixture on the model was trimmed with a laboratory scalpel to produce the scalloped gingival form. Light curing composite resin was added to fill the space between the provisional crown base and trimmed gingiva. After 4 to 6 weeks, the final impression was taken to make a definitive implant restoration, where the soft tissue and tooth form were in harmony with the adjacent tooth. Results: At the first insertion of the provisional restoration, gum bleaching revealed gingival pressure. Four to six weeks after placing the provisional restoration, the gum reformed with harmony between the peri-implant gingiva and adjacent dentition. Conclusions: Gingival recontouring with a provisional implant restoration is a non-surgical and non-procedure-sensitive method. The implant restoration with the optimal emergence profile is expected to provide superior esthetic and functional results.

SEVERAL METHODS OF FABRICATIONS OF INNER CROWN AND OUTER CROWN IN CONSTRUCTION OF KONUS DENTURE (다양한 Konus denture의 내관 및 외관의 제작방법)

  • Chung Jun-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.406-413
    • /
    • 2002
  • The purpose of this article is the consolidation of several methods in fabrication of Konus denture. It is different Konus denture from traditional Clasped removable partial denture in the procedures of construction. There are multiple procedures of fabrications of inner and outer crowns in the construction of Konus denture. It is important to fabricate the inner crown, the outer crown and the denture framework in construction of Konus denture. Each procedure should be performed exactly. However, there are many procedures in fabrications of them, and thus, the operator and technician bear trial and error. This article consolidate the multiple methods of fabrications of components of Konus denture. The first method is completion of inner crown, outer crown and denture after one impression taking. The second method is the procedures of cementation of inner crown, impression taking of edentulous area, and completion of outer crown and denture. The third method is the procedures or pick up impression taking of inner crown and completion of outer crown and denture on the inner crown of working cast. Each method is acceptable, but operater and technician should be accustomed with their own systemic procedures and minimize the errors in the construction of denture.

Environments Pollution Caused by Welding Rod in the Process of Pipe Working (설비배관에서 용접봉에 따른 환경오염)

  • Yoon, Young-Mook;Lee, Woo-Ram;Lee, Chul-Ku;Kim, Joo-Han
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.3
    • /
    • pp.300-306
    • /
    • 2009
  • Welding technology is applicable in many kinds of fields, with the help of its advantages such as easy operational procedure and structural simplification. However, in the process of welding, hazardous materials and fumes cause huge fire broke-outs, explosions, and health-conscious problems. Also, as heavy metals in fumes have a harmful effect on the environment, recently, this has emerged as a urgent social issue. This study has been aimed at the recommendation of the most environment-friendly, among materials currently used in plumbing welding, and it has been done at the result of the analysis of amount, ingredient, and size in collected fumes created in the experiment of welding five rods to galvanized steel pipes and steel pipe ones. At the test result, due to the effect of Zn-coating, galvanized steel pipes, when welded to rods, created more fumes than steel pipe ones. In the mean time, when it comes to welding rods, among five, WR-03 produced fumes the least. Therefore, a combination of the test results clearly indicates that the case of welding WR-03 to cast-iron pipes turned out to be the most environment-friendly.

  • PDF

Steroid induced muscle atrophy (스테로이드 유발성 근위축)

  • Choe, Myoung-Ae
    • Perspectives in Nursing Science
    • /
    • v.2 no.1
    • /
    • pp.19-36
    • /
    • 2005
  • Muscle atrophy is defined as a decrease in muscle mass, cross-sectional area, and myofibrillar protein content. Causes inducing muscle atrophy may be inactivity, denervation, undernutrition and steroid. Inactivity may decrease protein synthesis and increase protein breakdown of skeletal muscle. The muscle atrophy due to inactivity was induced by bed rest, hindlimb suspension, cast, total hip replacement arthroplasty, anterior cruciate ligament reconstruction. Denervated atrophy may be induced by the loss of innervation from lower motor neuron. The atrophy was apparent in the lower limb of hemiplegic patients following ischemic stroke and in the hindlimb of ischemic stroke rats. Protein breakdown of skeletal muscle in the undernourished state results in muscle atrophy. The atrophy due to undernutrition was evident in cancer and leukemia patients and in the undernourished rats. Steroids have been used to treat allergies, inflammatory diseases, autoimmune diseases and to inhibit immune function following transplantation. Steroids may induce muscle atrophy by protein breakdown of skeletal muscle. Muscle Physiology Laboratoryat College of Nursing, Seoul National University proved that dexamethasone may induce hindlimb muscle atrophy in rats and exercise and DHEA may attenuate hindlimb muscle atrophy induced by the steroid in rats. Nurses working with patients undergoing steroid treatment need to be cognizant of steroid induced muscle atrophy. They need to assess whether muscle atrophy is being occurred during and after the steroid treatment. Moreover, they need to apply exercise and DHEA to the patients undergoing steroid treatment in order to attenuate the steroid induced muscle atrophy.

  • PDF

Change of Hydriding Properties of Gravity Cast Mg-Ni Alloys with Ni Content (Ni 첨가량에 따른 중력 주조 Mg-Ni 합금의 수소화 반응 특성의 변화)

  • Yim, C.D.;Moon, Y.M.;You, B.S.;Na, Yeong-Sang;Bae, Jong-Su
    • Journal of Hydrogen and New Energy
    • /
    • v.15 no.3
    • /
    • pp.250-256
    • /
    • 2004
  • Magnesium and its alloys have the high potential as hydrogen storage materials because of their highest hydrogen storage capacity, low density and abundant resources. But poor kinetic properties of hydriding and dehydriding and high working temperature have limited their practical applications. In this study, the Mg-Ni binary alloys with different amount of Ni were produced by gravity casting and characterized in order to investigate the relationship between the microstructures and hydriding properties. The maximum hydrogen absorption capacity decreased, but the absorption kinetics increased with Ni content. The difference in the absorption kinetics was resulted from the differences in the sort and shape of primary solid phases and eutectic microstructure.

Dynamic Bulging Behavior Analysis by Finite Difference Method in High Speed Continuous Casting of Thin Slab (유한 차분법에 의한 Thin Slab 고속 연속주조의 동적벌징 거동해석)

  • Jeong, Yeong-Jin;Sin, Geon;Jo, Gi-Hyeon;Gang, Chung-Gil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.7 s.178
    • /
    • pp.1650-1660
    • /
    • 2000
  • Continuous casting process has been adopted increasingly in recent years to save both energy and labor. It has experienced a rapid development in the production of semi-finished steel products, rep lacing the conventional route of ingot casting and rolling. In order to achieve this merit, however, more studies about the mechanism between roll and slab are needed. In this paper, a dynamic bulging in steel cast slabs was simulated by considering the solidification and heat transfer. This study is to prevent internal cracks of a slab in a bending and unbending zone. The value of moving strand shell bulging between two supporting rollers under the ferrostatic pressure and slab-self weight has been calculated in terms of creep and elasto-plasticity. The strain and strain rate distributions in solidified shell undergoing a series of bulging are calculated with working boundary conditions.

Fabrication of Thin Plate of Semisolid Material using Slope Plate Process and Development of Fabrication Apparatus (Slope plate 공법을 이용한 반응고 박판 및 제조 장치 개발)

  • Koo, Ja-Yoon;Bae, Jung-Woon;Jin, Chul-Kyu;Kang, Chung-Gil
    • Journal of Korea Foundry Society
    • /
    • v.32 no.1
    • /
    • pp.24-31
    • /
    • 2012
  • In this study, semi-solid thin plate of A 356 aluminum alloy was fabricated by using slope plate apparatus and vacuum pressurization. Slope plate was used to produce semi-solid material with spheroidal microstructures. After molten metal was poured into the slope plate connected to the pouring hole of die, semi-solid material flowed into the die cavity by vacuum degree. The primary crystals of the cast metal became spheroidal. In order to increase the working pressure, gas pressurization of U shape was designed for fabrication of thin plate. For 3 bar of gas pressure and 60 mmHg of vacuum degree, thin plate was fabricated without defects on surface.

Analysis and structural design of various turbine blades under variable conditions: A review

  • Saif, Mohd;Mullick, Parth;Imam, Ashhad
    • Advances in materials Research
    • /
    • v.8 no.1
    • /
    • pp.11-24
    • /
    • 2019
  • This paper presents a review study for energy-efficient gas turbines (GTs) with cycles which contributes significantly towards sustainable usage. Nonetheless, these progressive engines, operative at turbine inlet temperatures as high as $1600^{\circ}C$, require the employment of highly creep resistant materials for use in hotter section components of gas turbines like combustion chamber and blades. However, the gas turbine obtain its driving power by utilizing the energy of treated gases and air which is at piercing temperature and pushing by expanding through the several rings of steady and vibratory blades. Since the turbine blades works at very high temperature and pressure, high stress concentration are observed on the blades. With the increasing demand of service, to provide adequate efficiency and power within the optimized level, turbine blades are to be made of those materials which can withstand high thermal and working load condition for longer cycle time. This paper depicts the recent developments in the field of implementing the best suited materials for the GTs, selection of proper Thermal Barrier Coating (TBC), fracture analysis and experiments on failed or used turbine blades and several other designing and operating factors which are effecting the blade life and efficiency. It is revealed that Nickel based Superalloys were promising, Cast Iron with Zirconium and Pt-Al coatings are used as best TBC material, material defects are the foremost and prominent reason for blade failure.

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.