• Title/Summary/Keyword: Working Condition and Environment

Search Result 335, Processing Time 0.024 seconds

The Characteristics of the Learning Performance according to the Indoor Temperature of the Learning Environment and the Color of the Learning Materials (학습 환경의 실내 온도와 학습재료의 색채에 따른 학습수행의 특성)

  • Kim, Boseong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.681-687
    • /
    • 2013
  • This study examined whether the combination of the indoor temperature on the learning environment and the colors of the learning materials affect the learning performance. To do this, the condition of indoor temperature was divided into three conditions: the neutral condition which is the appropriate temperature condition of the learning activities ($22.5{\sim}24^{\circ}C$), the high-temperature condition (> $24^{\circ}C$), and the low-temperature condition (< $22.5^{\circ}C$). In addition, colors of red, blue, black, and green were used as the warm, cold, and neutral colors, and the verbal-working memory task was used as the learning task. As a result, it was not significant differences in the response time of the learning task, whereas, in the accuracy rate of the learning task, the performance was more accurate in red- and black-color conditions. These results could be interpreted as the saliency and color-temperature of the red color, and the familiarity and specificity of the black color.

On the Countermeasure for Preventing the Accident of Cargo Handling in Port (항만하역관할의 원인분석 및 예방대책에 관하여)

  • 박용욱;이철영
    • Journal of the Korean Institute of Navigation
    • /
    • v.17 no.3
    • /
    • pp.57-68
    • /
    • 1993
  • The economy of Korea has grown up significantly in its scale. It has, therefore, become imperative to develop countermeasures to prevent work related injuries and occupational illnesses resultining from haza-rdous working conditions and handling harmful substances. A lot of cargo handling accident in port have occurred due to the characteristics of poor working environment, diversity of working place and method, fluctuation of the amount of cargo and handling of heavy, long, harmful and dangerous cargo, etc. According to '91 industrial accident analysis carried out by the ministry of labour, the number of the stevedores injured by cargo handling accident in port were 1, 432 persons (the death accident : 22 per-sons), the amount of industrial accident compensation in port was 6.7 billion won (the amount of economic loss : 33.6 billion won), and the injury occurance rate of the stevedoring industry was higher than that of the whole industry. This paper, therefore, aims to the actual status of the stevedoring industry and to extract the main cau-ses of the accidents related to cargo handling in port through factor analysis using the data of the accide-nts in the whole habour from 1990 to 1992, and to suggest the countermeasures to prevent such accident. The main causes of the accident and countermeasures are found to be as follows through the factor analy-sis : Factor1, factor2, and factor3 related to a defect of human being and management, a defect of state and environment, and an insufficiency of education and law are extracted. The short-term countermeasures to prevent these accidents are 1) to consolidate the safety and health organization in the working spot, 2) to secure a safe condition in working spot before dock work, 3) to strengthen a dock worker's safety educa-tion. The long-term countermeasures are 1) to promote a decasualisation of dock workers, 2) to modernize the cargo working methods through constructing exclusive pier and introducing exclusive cargo handling equipment, 3) to establish a exclusive dock accident prevention organization and the dock workers law. Factor 4, factor5, factor6, and factor7 related to an unfitness, a deficiency of technical knowledge, a nonfu-lfilment of safety measures, and a bad arrangement are extracted. The countermeasures to prevent these accidents are 1) to perform a complete safety inspection of cargo handling equipments and tools and to carry out the dock work according to a working plan, 2) to publish and supply technical safety books, safety instruction book, safety check list, etc., 3) to strengthen the safety patrol at the working spot in habour and to activate a safety fund, 4) to maintain always a clean workshop with the safety consciousness in which the good arragement of the working spot is considered to be the beginning of safety.

  • PDF

Desorption characteristics of Activated Carbon and Activated Carbon Fiber by Development of Sorbent Tube for Measurement of Organic Solvent (유기용제 측정용 흡착관 개발을 위한 AC 및 ACF의 흡착특성)

  • 원정일;김기환;신창섭
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.99-109
    • /
    • 2002
  • Charcoal $tube/CS_2$ method are more popularly used than any other in the measurement of the working environment for the exposure evaluation of organic solvent, but it is some weak points that the lower accuracy can be obtained on the polar materials and within the range of the low concentration. Thus solvent desorption method has been developed to make accuracy higher and to overcome some weak points. However, because of high price of adsorption tube for thermal desorption and the short of study on its application to the working environment, it is not popularly used in the domestic industrial hygiene fields. This dissertation aims to develop thermal desorption and adsorption tubes for measuring organic solvents in the working environment, by comparing and analyzing breakthrough condition and adsorption capacity with ACF. Specific surface area of ACF used in this study is wider than the one of AC and micropore of ACF related with adsorption has been developed, and adsorption velocity and adsorption amount are very excellent by linking a pore of surface and an inside well into micropore. 1. Result of analysis on physical characteristics of adsorbent, the specific surface area of ACF was 1.3 times higher than that of AC. Distribution ratio of micropore related to adsorption was 94% on ACF and AC. Result of SEM, micropore of the AC is opened to the surface. In contrast, ACF shows that extremely fast adsorption speed. Because of micropore are exposed on the surface and penetrate through each other. 2. Breakthrough characteristics of adsorbents was not different from slop of breakthrough curve. The effluent concentration reaches 10% of initial concentration($C_{out}/C_{in}=0.1$, break point) of ACF was 30~316min longer than that of AC. Therefore, the adsorption capacities of ACF was 1.1~4.6 times higher than that of AC. ACF can be used as a proper adsorbent for measurement of organic solvent.

The Problem on Urban Regeneration of Korea (우리나라 도시재생의 과제)

  • Baek, Seung-Gwon;Kim, Jong-Hwan
    • Journal of the Korean Professional Engineers Association
    • /
    • v.41 no.4
    • /
    • pp.32-37
    • /
    • 2008
  • This Report intends theoretical background of urban planning, related national law system and instances to be researched and concluded as follows below and also to be shared with planners working in the field of urban planning technique services. Revision of new laws and systems are necessary for the reasonable Urban Regeneration promotion through comprehensive and systematic supporting composition revision. For the reason hereafter urban regeneration shall be various and inclusive in society, economy, culture, environment, resident participation. etc., the development model for regeneration project complying with Korean Urban Regeneration condition is required. Diversity and flexibility through governance system are required to ensure city competitive power.

  • PDF

A Study on the improvement of working condition in the downtown Underground construction - Focused on the Ventilation and Lighting - (지하건설공사의 작업환경 개선에 관한 연구 -환기와 조명을 중심으로-)

  • 고성석;안홍섭
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.119-132
    • /
    • 1997
  • According to the construction environmental changes due to the trend of large scale and complicated building construction, many construction methods(such as : TOPDOWN )are more often used. However, it is pointed out that occupational pulmonary diseases, reduction of the machinery lifetime and productivity caused to be narrow visual field and collision between the workers. Therefore, this study is mainly dealing with the views of productivity and safety improvement in order to improve work efficiency and to insure the safety in underground construction environment.

  • PDF

A subjective symptom on indoor air quality in dental hygienist (치과위생사의 실내공기질에 의한 자각증상 특성)

  • Choi, Mi-Suk;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.4 s.62
    • /
    • pp.1-10
    • /
    • 2006
  • This research is based on self-filling survey which 220 dental hygienists who work in seoul participated on July 2006 through August 2006. This survey was analyzed the experience item and occurred time of the symptoms and the time of acute and vanish of the symptoms that dental office's working environment effects on physical subjective symptom. We suggest a plan to minimizing physical subjective symptom for health manage of dental hygienist. We found out the fact that dental hygienists were unsatisfied with hospital air condition and this polluted air condition cause them physical subjective symptom in work place. As follows analyzed results ventilation time is below the 3-times a day, this may be have some trouble in indoor air quality. The experience the symptoms level is higher then non-experience level in "Fatigue and sleepiness", "Dorsalgia, omarthralgia, cervicodynia", "Hypersensitivity", "Dry eye, itch, smarting", "Headaches" and a subjective symptom is occurred at after 11:00(am) more then 60%, 50% of the dental hygienist. This experience the symptom' pain is vanished after the work and reduced when go out the office and building, respectively. The ratio of the experience the symptoms and starting time the symptoms is anywhere from 12 noon to 4 pm (73.2%) in a day. The time of acute pain the symptoms is anywhere from 12 noon to 4 pm (78.7%) refer to the individual characteristics and work environment.

Nurses' Perception of Flexible Working and Its Operational Guideline (간호사의 시간선택제 근무에 대한 인식과 근무방안)

  • Kim, Miyoung;Kim, Eunjung;Choi, Sujin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.664-675
    • /
    • 2016
  • The purpose of the study was to explore the nurses' perception of flexible working and present an operational guideline for implementation. The data were collected from a survey of 532 nurses conducted from 10 February to 24 February, 2015, using simple random sampling. SPSS 21.0 was used to analyze the data. This study found that the demanding for shorter hour shifts was highest ($M=3.89{\pm}0.87$) and 242 participants (46.2%) intended to apply the shift, followed by a fixed night shift, fixed weekend shift, and 12 hour shift. The common reasons identified were the poor environment of shift work and the challenges of child care. The increased time for personal development, relaxation activity to improve the quality of life and child care was highlighted and work-life balance was noted as a positive impact of flexible working. The negative impacts of flexible working were being likely to become temporary workers. These results can help establish uniform working conditions of nurses in the future by providing a standardized operational guideline as a precondition for reasonable compensation and working environment according to a flexible working pattern.

A Study on the Harmfulness of Silicon Oxide Dust and Measures for the Work Environment Improvement in Construction Sites (건설현장에서 발생하는 산화규소분진의 유해성 및 작업환경 개선대책에 관한 연구)

  • Hwang, Jeong-Suk
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.478-486
    • /
    • 2022
  • Purpose: Although the working environment is measured at the construction site, only a few noise and vibration that are typically exposed for each process are performed without measuring the working environment by segmenting the exposed harmful factors. Therefore, it is intended to find the harmfulness of silicon oxide dust, which is most exposed at construction sites, and the complementary points of improvement measures currently being implemented at construction sites. Method: The status was analyzed using the actual condition survey report issued by the Korea Occupational Health Corporation and the Korea Occupational Health Association and data from the work environment measurement institution, and compared and analyzed with the rules on work environment measurement of the Occupational Safety and Health Act. Result: The harmfulness of silicon oxide dust was identified and improvement measures were derived. Conclusion: It is expected that occupational diseases against silicon dust can be reduced if the harmfulness of silicon oxide dust at construction sites is derived and improvement measures are actively applied at the site.

A Plan to Ensure Safety of Electric Installation in Empty houses During Normal Working Hours (부재수용가의 전기설비에 대한 안전확보 방안)

  • Lim, Young-Bae;Jung, Jong-Wook;Jung, In-Soo;Bae, Seok-Myung;Cho, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.25-26
    • /
    • 2006
  • An electrical fault is defined as any abnormal condition caused by reduction in the insulation strength between energized conduction parts and ground or any grounded part of an electrical system. Failure of solid insulation can be caused by excessive mechanical tension being applied on the insulation, harsh service environment, aging, and also by corona phenomena. The number of empty houses during normal working hours is rising. As a result, the number of uninspected electric installation for general use is increasing. To define the potential risk of the electric installation, measurement of leakage current has been getting considered, but because the measured leakage current value also contained leakage current by capacitance, the measured value can not be adapted to absolute reference to the installation. Therefore, in this paper, the correlation between the condition of electric installation and leakage current were analyzed.

  • PDF

A Study on Actual Condition of the Noise in a Factory (일 제조업체의 작업장 소음실태에 관한 연구)

  • Shin Soo Ok
    • Journal of Korean Public Health Nursing
    • /
    • v.9 no.2
    • /
    • pp.43-51
    • /
    • 1995
  • Many poeple has been engaged in industry is aware of the dangers from exposure to high intensity nose levels. The exposure to high intensity noise is encountered in a large number of situations. Laws governing the safety and health of employed people being to create a suitable working environment and eliminate unsafety practices and processes. Work areas should be designed and laid out so that they are satisfactory both from the environmental and safety points of view. In this connection safety also implies that noise is kept at a level which is not likety to cause hearing damage. This study was performed to measure the noise of press and assembly process in an automobile factory. and suggested the method of noise control. Consequently the effect ways of reducing level in working environment are as follows; 1. Changes to machines which would reduce noise generation. 2. Alteration of equipment to avoid impact in machinery and handing materials. 3. Enclosure of noisy machines or machine parts. 4. Mounting of attenuators on gas and air outlets as well as ventilation ducts. 5. Erection of sound absorbing screens. linings. and baffles in work areas. 6. The personal ear protectors can be chosen to protect the workers.

  • PDF