• Title/Summary/Keyword: Wood fiber

Search Result 477, Processing Time 0.025 seconds

Longitudinal Bonding Strength Performance Evaluation of Larch Lumber (낙엽송 소경각재의 종접합 성능평가)

  • Lee, In-Hwan;Pack, Ju-hyun;Song, Da-bin;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.85-92
    • /
    • 2018
  • In order to use glued built up timber beam as a structural member for post and beam construction, it must be possible to manufacture long-span lumber. In this study, the researchers conducted a performance evaluation for longitudinal bonding of lumber (cross-section $89{\times}120mm$) made from larch. The specimens were prepared in six different forms using the longitudinal bonding method. The bonding strength of these specimens was tested through tensile strength tests and bending strength tests. The tensile strength test result of the longitudinally bonded parts was better than that of the double lap specimens. And, the tensile strength value of the scarf specimen was better than that of the hooked scarf specimen. The tensile strength of the GFRP (Glass Fiber Reinforced Plastic) rod insertion bonding specimen was 3.6 MPa, which was the highest. As for the bending strength test result of the longitudinally bonded part, the average MOR (modulus of rupture) of the specimen where a GFRP rod was inserted and bonded measured 29 MPa, while the specimens of other bonded parts showed a MOR no more than 11 MPa. Toughness destruction was observed in specimens where a GFRP rod was insertion-bonded. The rest of the specimens showed brittle destruction. The average MOR strength of the Rod + Lap specimen was 30.5 MPa, which was the highest among all longitudinally bonded specimens. The bending strength of the Rod + Lap specimens showed an effective strength that was 66% of that of the control group which were not longitudinally bonded.

Adhesive Performance and Fracture Toughness Evaluation of FRP-Reinforced Laminated Plate (FRP 보강적층판의 접착성능 및 파괴인성평가)

  • Jung, Hong-Ju;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.868-875
    • /
    • 2015
  • In order to replace existing slit type steel plate on the wooden structure joint, the FRP-reinforced laminated plates were produced. Four types of FRP-reinforced laminated plates were produced according to the type of reinforcement and adhesive, and before applying to the joint, the adhesion performance test according to KSF 3021 and KSF 2160 and the Compact Tension (CT) type fracture toughness test specified in ASTM D5045-99 were carried out. As a result of adhesion performance test, all GFRP textile, GFRP sheet, and GFRP Textile-Sheet type FRP-reinforced laminated plates satisfied the requirement of soaking delamination percentage with smaller than 5% based on KS standard. However, aramid type specimen satisfied the standard as the soaking delamination percentage of 4.8% but it did not satisfied the standard as the water proof soaking delamination percentage of 70%. As a result of fracture toughness test, the volume ratio of reinforcement to timber became 23% so that the strength of FRP-reinforced laminated plates increased by two to four times in comparison to the control specimen. It was confirmed that the GFRP Textile-Sheet type specimen was most resistant to the fracture most since the ratio of stress intensity factor compared with that of the control increased to 61% owing to the parallel arrangement of glass fiber to the load. As a result of tensile shear strength test using FRP-reinforced laminated plates and nonmetal dowels, it is about 12% lower than metal connectors.

Moment Resistance Performance Evaluation of Larch Glulam Joint Bonded in Glass Fiber Reinforced Plastic Rods (봉형 GFRP를 삽입접착한 낙엽송 집성재 접합부의 모멘트저항 성능 평가)

  • Lee, In-Hwan;Song, Yo-Jin;Jung, Hong-Ju;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.60-67
    • /
    • 2015
  • In order to evaluate the bond performance of domestic larch glulam and the glass fiber reinforced plastic (GFRP) rod, the specimen with the GFRP rod bonded-in domestic larch glulam for pull-out test was produced. The test was carried out using various specimens with different gluing depth, width of glue-line and type of adhesive. The cantilever type rahmen structure specimen with bonded-in GFRP rods was produced based on the result of pull-out test, and its moment resistance performance was compared and examined with the moment resistance performance of slotted-in steel plate specimen. As a result of the pull-out test, the most excellent bond performance was found when the insertion depth of GFRP rods was 5 times larger than the diameter of GFRP rods. When the glue-line thickness was 1 mm, the bond performance improved by 17%~29% in comparison to the bond performance in the case of the glue-line thickness of 2 mm. Also, the bonded strength of the specimen used with poly-urethane adhesive was 2.9~4.0 times greater than the bonded strength of specimen used with resorcinol adhesive. The cantilever type rahmen structure specimen with bonded-in GFRP rods showed the moment resistance performance 0.82 times lower in comparison to the slotted-in steel plate specimen used with the drift pin, but the initial stiffness was similar as 0.93 times.

Performance Evaluation for Bending Strength and Tensile Type Shear Strength of GFRP Reinforced Laminated Wooden Pin (GFRP보강적층목재핀의 휨강도 및 인장형 전단내력 성능평가)

  • Song, Yo-Jin;Jung, Hong-Ju;Kim, Dae-Gil;Kim, Sang-Il;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.258-265
    • /
    • 2014
  • By replacing the previous metal connector on the joints of timber structure, the GFRP reinforced laminated wooden pin was produced using a wooden material and Glass fiber reinforced plastic(GFRP) composite laminate. In addition, using the reinforced wooden pin, the tensile type shear strength test was conducted. Based on the result of the bending strength test of the reinforced laminated wooden pin according to the GFRP arrangement, a specimen(Type-A) with a single insertion of GFRP for each layer have shown the most favorable performance. Also, it was verified that densified specimen hot pressed for an hour at the temperature of $150^{\circ}C$ and with the oppression pressure $1.96N/mm^2$ have shown the improved performance of 1.57 times than the specimen without the densification. And in the bending strength test considering the load direction, edgewise have shown a higher performance of 3.51 times than the flatwise. A shear strength test was conducted using the Type-A reinforced laminated wooden pin which have shown a moderate performance on the test. Based on the test conducted by differentiating the type of the joint plate and the connector, compared to the specimen(Type-DS) applied with the drift pin and steel plate, the specimen( Type-WL) applied with the GFRP reinforced laminated wooden pin and GFRP reinforced wooden laminated plate have shown 1.12 times higher shear strength and also have shown an excellent toughness even after the maximum load.

Structural Performance of Joints for Partial Reinforced Beam Using GFRP Laminated Plate and Cylindrical Reinforced LVL Column (GFRP적층판을 활용한 보강보부재와 원통형 단판적층기둥재 접합부의 내력 성능평가)

  • Song, Yo-Jin;Jung, Hong-Ju;Lee, Jung-Jae;Suh, Jin-Suk;Park, Sang-Bum;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.282-289
    • /
    • 2014
  • After being laminated with a combination of glass fiber reinforced plastic and plywood, the GFRP laminated plate was densificated for 1 hour at $150^{\circ}C$ with pressure of $1.96N/mm^2$. A partial reinforced beam was produced by attaching the 5 GFRP laminated plates to the joint of glulam and the column. In addition, the column to beam joint was produced by using reinforced laminated wooden pin which was made of GFRP sheet and plywood, fiber glass reinforced cylindrical-LVL column. The joint was made of round log, glulam and drift pin as the reference specimen, and its moment resistance was evaluated. As a result, the strength performance of specimens with partial reinforced beams were 1.8 times stronger than the reference specimen on average. Furthermore, rupture was neither occurred on partial reinforced beam nor column. Toughness and stiffness of joints were also fine. The GFRP sheet reinforced laminated plate showed better reinforcement effect than GFRP textile reinforced one. GFRP sheet was inserted into each layer of laminate, and it showed good condition in rotation-angle and strength, therefore it is the most appropriate to reinforce the part of the beam.

Changes in Properties of Tropical Kapok Fibers by the Pretreatments (열대산 케이폭 섬유의 전처리에 따른 특성 변화)

  • Shin, Soo-Jeong;Jung, Woong-Ki;Sung, Yong Joo;Lee, Joon-Woo;Kim, Se-Bin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.1
    • /
    • pp.52-58
    • /
    • 2013
  • The effets of the pretreatments of tropical kapok fibers were evaluated in this study in terms of water sorption capacity and oil sorption capacity. The alkali treatments with NaOH resulted in the reduction of lignin, oil and hemicellulose, which were detected with FT-IR spectrum. The reduction of the lyphophilic components such as fat on kapok fiber by the ozone treatments were also measured with FT-IR spectrum. The oil sorption capacity of kapok fiber was decreased by the alkali treatments and the ozone treatments, while the water sorption capacity was increased. The liquid sorption capacity were greatly affected by the mechanical cutting of kapok fiber which exposed the big lumen of kapok fiber. The hydrophilic property of kapok fiber could be controlled by the pretreatments, which would increase the applicability of kapok fiber for preparation of various functional paper products.

Fiber Surface Engineering to Improve Papermaking Raw Material Quality

  • Wang Eugene I-Chen;Perng Yuan Shing
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06b
    • /
    • pp.271-278
    • /
    • 2006
  • We used polymers of alternating cationic and anionic nature to build up shells on fiber surfaces, strengthen the worn-out fibers and improve paper properties made from such fibers. OCC and ONP pulps were either dipped or salted out in the cationic polyallylamine, polyacrylamide and starch solutions. After centrifugal drying, these were followed by treatments in anionic polyacrylic acid, poly-acrylamide, and starch solutions, respectively. The shell-enhanced fibers were formed into handsheets and their physical properties evaluated. The results show that building multiple shells on worn-out fiber surfaces can strengthen the fibers and paper. The simpler and more practical impregnation-centrifuging treatment provided the desired effects, whereas salting out the polymers produced somewhat superior fibers. The latter process, were impractical, however. The first pair of polymeric shells imparted marked strength improvement, whereas later layers had diminishing efficacies. Overall, the methods can improve fiber quality, attaining paper strength requirements without resorting to expensive measures. Alternate cationic polymer and filler powders were also deposited on fiber surface based on the micriparticle system in an anticipation of stiffness gains. Platy minerals, such as montmorillonite, bentonite, sericite, clay and talc were added following cationic PAM. After dewatering of polymer-pigment shelled fiber of one to 3 pairs of layers, handsheets either calendered or uncalendered were evaluated. The results indicate that regardless of calendaring, stiffness of the handsheets did not improve appreciably while certain other strength properties showed gains. We also attempted the novel starch gel filler addition method wherein tapioca starch and filers (PCC, sericite or clay) were mixed at high solids content of 50% and cooked until gelatinized. The filled handsheets were dried under various conditions and then tested for their properties. Improvements in strengths of modified filled paper were observed.

  • PDF

Anatomical Characteristics of Major Plantation Species Growing in Indonesia II (인도네시아산 주요 조림수종의 해부학적 특성 II)

  • Jang, Sa-Ra;Jang, Jae-Hyuk;Kim, Jong-Ho;Febrianto, Fauzi;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.635-645
    • /
    • 2014
  • The anatomical characteristics of eight major wood species planted in Indonesia were investigated to provide valuable information for their effective utilization. The growth-ring boundaries of Damar and Sumatran pine were indistinct. Resin canal was found in Sumatran pine but it was not observed in Damar. Cupressoid pit and taxodioid pit were found in Damar and window-like pit and pinoid pit were observed in Sumatran pine. Tracheid length of Damar and Sumatran pine was shorter than $3,000{\mu}m$. There were uniseriate rays in Damar and Sumatran pine and fusiform ray in Sumatran pine. All the hardwood species observed in this study were diffuse-porous. They had different vessel groups, i.e., solitary pore in Afrika and Simpur Batu, pore cluster in Angsana and mostly 2-4 rows of radial pore multiple in Mahoni. Mindi and Trembesi had mostly 2-3 rows of radial pore multiple with paratracheal parenchyma as aliform and confluent types. Afrika, Mahoni and Simpur Batu showed heterocellular rays which composed of procumbent cells in the body and mostly 1-2 rows of upright and/or square cells in the margin. All ray cells procumbent was observed in Angsana, Mindi and Trembesi. The large rays commonly exceeding 1 mm in height and ray width of 3~6 cells were observed in Simpur Batu. The other five hardwood species showed ray width of 1~3 cells. Vessel number per $mm^2$ of Angsana and Simpur Batu was higher than those of the other hardwood species. The length of wood fiber and tracheid showed a tendency to increase from pith to bark. By IAWA list, fiber length of hardwoods was classified into long in Simpur Batu and short in Angsana and Trembesi.

Bending Performance of Glulam Beams Reinforced with Carbon Fiber-Reinforced Plastics Bonded with Polyvinyl Acetate-Based Adhesive (초산비닐수지계 접착제를 사용한 탄소섬유강화플라스틱 복합집성재의 휨 성능)

  • Park, Jun-Chul;Shin, Yoon-Jong;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.364-371
    • /
    • 2009
  • This study was carried out to investigate the bending strength of the Larix glulam beams which were reinforced with CFRP (Carbon fiber reinforced plastic) of which the reinforcement ratios were 0.7% and 2.1% by volume. In the bending test, the rupture shape of the reinforced glulam shows that the reinforced glulam broke firstly in the lowest bottom layer on which tension was loaded, but did not in the upper part reinforced with the CFRP layer. The upper part of the reinforced layer kept strength and did not break when the reinforced glulam broke firstly at the bottom part of the reinforced layer, but broke secondly as loading was increased. In the glulam beams reinforced with CFRP of which the reinforcement ratio was 0.7% by volume, the bending strength of the reinforced beams was increased by 28% at the first break. When beams broke up to the upper part of the reinforced layer, the bending strength of the reinforced beams was increased by 55%, compared to those of control glulam beams. When the glulam beams were reinforced with CFRP of which the reinforcement ratio was 2.1% by volume, the bending strength of the reinforced beams was increased by 77%, compared to those of control glulam beams. The ratio of the height of calculated neutral axis using failure mode recommended by Romani and the height of actual neutral axis using strain gauge was 1.03 and agreed well.

Evaluation of The Moment Resistance of Reinforced Wooden Gusset to Glulam Joint (보강목질적층판이 사용된 집성재 접합부의 모멘트 저항성능 평가)

  • Lee, In-Hwan;Song, Yo-Jin;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.53-61
    • /
    • 2017
  • In this study, specimens were produced with a column member and a wooden gusset only by inserting an wooden gusset which is a substitute for steel plate into the center of a slit-processed column member. The moment resistance performance of the specimens was compared with that of control specimens that used a steel plate. The measured maximum moments of the specimens produced with GFRP-reinforced wooden laminated gussets and pins were lower by 24% on average compared to the steel plate-inserted specimens, but they showed good toughness. The fracture shape suggests that it was fractured along the annual rings between the pin and the end of the column member. The rigid specimen that integrated a laminated wood and a wooden laminated gusset with adhesive showed 2.8 times greater initial rigidity and 40% greater maximum moment on average compared to the control specimen. The rigid specimens mainly fractured on a glulam around glue line.