Operational Characteristics of Transformer-Type SFCL with or without Neutral Line between the Secondary windings and Superconducting units (2차 권선과 초전도 사이의 중성선 유무에 따른 변압기형 초전도 한류기의 동작특성)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Go, Sung-Pil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1268-1273
    • /
    • 2011
  • The study on power capacity increase of superconducting fault current limiter (SFCL) is one of the most important researches to apply a SFCL in the power system. To achieve this, we thought that the unbalanced quenching problem generated in series connection of superconducting units should be solved. In this paper, we investigated the quenching characteristics of superconducting units in the transformer-type SFCL with or without the neutral line between secondary windings and superconducting units. In case of transformer-type SFCL without neutral line, the connection structure of superconducting units is identical to that of the resistive-type SFCL connected in series. Therefore, the unbalanced quenching was occurred by difference of critical current between superconducting units. However, in case of transformer-type SFCL with neutral line, the superconducting units with different critical current were simultaneously quenched. It was because the currents induced by secondary winding were separately flowed through the superconducting units. By these results, we confirmed that the resistances and consumption powers of the superconducting units were equally generated.

Scott Transformer Modeling using Simulink on the AC Substation (Simulink를 이용한 교류 급전변전소의 스코트변압기 모델링)

  • Kim, Tae-Geun;Park, Young;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2317-2322
    • /
    • 2011
  • In three-phase power, when the power is supplied to the single phase load, there is the unbalance of load in the three-phase power. So the scott transformer is used in the power system to supply a single phase load in three-phase power without the unbalance of loads. Especially, the scott transformer is used in the AC substation of electric railroad. Two single phase transformers are combined by T-wiring in the scott transformer. So, two single phase voltage is provided by differing $90^{\circ}$ phase in three-phase power. The selection of related equipment and correction of protective relay are not easy from characteristic of the scott transformer when shunt and ground faults occur. In this paper, electric model of the scott transformer is suggested and the current of the scott transformer in shunt and ground faults is analyzed. Also, the scott transformer model is demonstrated by using Sinulink.

  • PDF

Scott Transformer Modeling using PSIM on the AC Substation in the Elect ric Railroad (전기철도의 교류 급전변전소에서 PSIM을 이용한 스코트변압기 모델링)

  • Kim, Sung-Dae;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1892-1897
    • /
    • 2010
  • In three-phase power, when the power is supplied to the single phase load, there is the unbalance of load in the three-phase power. So the scott transformer is used in the power system to supply a single phase load in three-phase power without the unbalance of loads. Especially, the scott transformer is used in the AC substation of electric railroad. Two single phase transformers are combined by T-wiring in the scott transformer. So, two single phase voltage is provided by differing $90^{\circ}$ phase in three-phase power. The selection of related equipment and correction of protective relay are not easy from characteristic of the scott transformer when shunt and ground faults occur. PSIM(Power Electronics Simulator) is optimal simulation software in field of the power electronics and provide the simple and convenient user interface. In this paper, electric model of the scott transformer is suggested and the current of the scott transformer in shunt and ground faults is analyzed. Also, the scott transformer model is demonstrated by using PSIM.

  • PDF

A study on gas dissolved distribution in oil for simulated transformer thermal faults (변압기 열열화 모의 고장어 대한 유중가스 분포연구)

  • Sun, J.H.;Yi, S.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1800-1802
    • /
    • 2003
  • This paper describes a study on gas dissolved distribution in oil for simulated transformer thermal faults. Experimental chamber was setup for simulation of transformer thermal faults or discharge in oil with or without insulation paper. The experimental results showed that dissolved gases in oil excluding the paper did not evolved upto $150^{\circ}C$. Hereafter the planned gas dissolved analysis will be continuously carried out for transformer fault conditions with or without insulation paper related to water absorption, arc and partial discharge.

  • PDF

The Safety Survey Analysis and Consideration of Small Transformer (소형 변압기 안전성 실태 분석 및 고찰)

  • Kim, Sung-Sam
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, safety certification products and safety condition of small transformer is analyzed in industries field and educational facilities. In transformer of 50places, absolute majority is step down transformer to measure of instrument. Most transformers were below 5kVA and 1~3kVA capacity was the mainstream. In industries field, 5 transformers were found without safety certification according to the Electrical Appliances Safety Control Act as cheap product prefer and lack of safety consciousness. Mark & number, voltage, date of manufacture of safety certification must show item of certification. However date of manufacture showed in product of 18%, 9places. As result of thermal imaging camera, running temperature of transformer was showed in below of target temperature. However as a narrow space of transformer and wall, power cable was touched on a ventilating flue in transformer. It was simple carelessness case that surface fouling and temperature ageing of transformer accelerate. Power poor connection, neglect of transformer in production equipment, fall damage by setup incongruity and ground omission were found in case of illogicality item of transformer.

Transformer-less CCFL Driver for LCD Backlight (LCD 백라이트용 트랜스포머 없는 냉음극관(CCFL) 구동 회로)

  • Choi Eun-Seok;Yoon Hyun-Ki;Moon Gun-Woo;Youn Myung-Joong;Kang Moon-Shik
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.81-83
    • /
    • 2006
  • The conventional cold cathode fluorescent lamp (CCFL) driver for LCD TV has a transformer for each lamp to step up the high sinusoidal waveform from the low input voltage. The transformer used in the conventional topology causes the driver to have bulky size and high cost. This paper proposes a new transformer-less CCFL driver for LCD backlight that is based on the parallel-loaded resonant inverter topology. This resonant topology enables the circuit to supply enough high voltage for CCFL without a transformer. Also, with current-balancing technique, this transformer-less inverter drives 16 CCFL lamps.

  • PDF

Analysis on Current Limiting Characteristics of Flux-Lock Type SFCL Using a Transformer Winding (변압기 권선을 이용한 자속구속형 초전도 전류제한기의 전류제한 특성 분석)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.2
    • /
    • pp.136-140
    • /
    • 2011
  • The fault current limiting characteristics of the flux-lock type superconducting fault current limiter (SFCL) using a transformer winding were investigated. The suggested flux-lock type SFCL consists of two parallel connected coils on an iron core and the transformer winding connected in series with one of two coils. In this SFCL, the high-TC superconducting (HTSC) element was connected with the secondary side of the transformer. The short-circuit experimental devices to analyze the fault current limiting characteristics of the flux-lock type SFCL using the transformer winding were constructed. Through the short-circuit tests, the flux-lock type SFCL using transformer winding was shown to perform more effective fault current limiting operation compared to the previous flux-lock type SFCL without the transformer winding from the viewpoint of the quench occurrence and the recovery time of the HTSC element.

An analysis on the Parametric Transformer (Parametric Transformer의 동작해석)

  • Hwang, Young-Moon;Jeong, Kee-Hwa;Park, Han-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.31-33
    • /
    • 1991
  • A passive power converter operating on the principle of parametric excitation, called Parametric transformer, is analyzed. The energy transfer from the input to the output is achieved through the double frequency variation of magnetic path reluctance to the input frequency without mutual flux coupling between two windings. Thus, output becomes available which is essentially independant of waveform of excitation. The mathmatical model of the device is developed and its solution is obtained. The outstanding characteristics of the device is explained from the analysis.

  • PDF

Measurement of moisture contents of oil-paper in transformer with RVM (RVM을 이용한 변압기 절연유와 절연지의 온도에 따른 수분함유량 측정)

  • Han, Hee-Joon;Han, Sang-Ok;Lee, Sei-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.79-81
    • /
    • 2005
  • Chemical methods for moisture contents detection of insulation system in transformer must dismount equipment for sampling, and there is shortcoming such as acquiring partial data for measuring. Also the samples can't immediately analyze in field. The Recovery Voltage Method (RVM) will be able to measure a moisture contents at low voltage without dismounting equipment. Therefore, in advanced countries RVM would be used to measure the moisture contents which permeates to the insulation system without weighting additive degradation or mechanical damage. In this paper we have investigated for overcoming these shortcomings using the RVM, and we have measured the moisture contents of transformer insulation with temperature.

  • PDF

A Low-Loss On-Chip Transformer Using an Auxiliary Primary Part (APP) for CMOS Power Amplifier Applications

  • Im, Haemin;Park, Changkun
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.403-406
    • /
    • 2019
  • We propose a low-loss on-chip transformer using an auxiliary primary part (APP) for an output matching network for fully integrated CMOS power amplifiers. The APP is designed using a fifth metal layer while the primary and secondary parts are designed using a sixth metal layer with a width smaller than that of the primary and secondary parts of the transformer to minimize the substrate loss and the parasitic capacitance between the primary and secondary parts. By adapting the APP in the on-chip transformer, we obtain an improved maximum available gain value without the need for any additional chip area. The feasibility of the proposed APP structure is successfully verified.