• 제목/요약/키워드: Wiring technique

검색결과 55건 처리시간 0.023초

Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery

  • Oh, You Na;Ha, Keong Jun;Kim, Joon Bum;Jung, Sung-Ho;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • 제48권4호
    • /
    • pp.265-271
    • /
    • 2015
  • Background: Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA) was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Methods: Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Results: Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578), major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99), minor wound complications (3.6% vs. 2.0%, p=0.279), or mediastinitis (0.8% vs. 1.0%, p=1.00). Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068). Conclusion: The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

Sterile Necrosis of the Sternum: A Rare Complication Following Coronary Artery Bypass Surgery

  • Papadakis, Emmanouel;Konstantinidou, Maria Kalliopi;Kanakis, Meletios A.
    • Journal of Chest Surgery
    • /
    • 제50권6호
    • /
    • pp.460-462
    • /
    • 2017
  • We herein present the unique case of a 68-year-old male diabetic patient who developed sterile necrosis of the sternum 1 month after myocardial revascularization with the use of bilateral internal thoracic artery grafts. The sternum had been closed by the bilateral Robicsek wiring technique. The sternum was removed, and bilateral pectoralis major flaps were used to cover the defect. The patient had an uneventful recovery.

CMP 공정을 이용한 Multilevel Metal 구조의 평탄화 연구 (Planarization of Multi-level metal Structure by Chemical Mechanical Polishing)

  • 김상용;서용진;김태형;이우선;김창일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.456-460
    • /
    • 1997
  • As device sizes are scaled to submicron dimensions, planarization technology becomes increasing1y important, both during device fabrication and during formation of multilevel interconnects and wiring. Chemical Mechanical Polishing (CMP) has emerged recently as a new processing technique for achieving a high degree of planarization for submicron VLSI applications. This paper is presented the results of CMP process window characterization studies for 0.35 micron process with 6 metal layers.

  • PDF

간이 엘리베이터 수.자동 개폐배선 제어방식에 관한연구 (A Study on the Control Method of Hand & Automatic Operation of On-Off Wiring of an Easy Elevator)

  • 위성동;구할본;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1107-1112
    • /
    • 2002
  • An easy elevator originated is an opened system to compare an existing equipment, and learning efficient is high as a wiring that the sequence control circuit is on and off. The structure of an equipment to be controled from the first floor to the fifth floor is constructed by a lamp to express the function of the open-close of the door according to the cage moving, to express the mechanical actuation of the forward-reverse break and motor of load and of hand-worked control component of Push-Button S/W, L/S and Relay. In order to act of the elevator function that these components connected, designed the auto program and the sequence control circuit. Consequently the process that these(1~5steps) operated the cage with an auto program of the elevator and the sequence control circuit is controled by the step of forward and reverse that the L/S1~L/S5 of sensor adjust function let posit, by the adjustable S/W1~S/W5 of PLC testing panel and the S/W1~S/W5 which installed on the transparent acryl plate of a frame. In here, improved apparatus is the learning equipment of combined use to study the principle and the technique of the originated sequence control circuit and the auto program of PLC.

  • PDF

의료용 도뇨관 표면의 도선용 구리 박막 증착을 위한 스퍼터링-열증착 연속공정장비의 설계 및 개발 (Design and Development of Sputter-evaporation System for Micro-wiring on Medical Catheter)

  • 장준근;정석
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.62-71
    • /
    • 1999
  • Integrating micro-machined sensors and actuators on the conventional devices with the copper power lines was incompatible to fabricate the mass produced micro electromechanical system (MEMS) devices. To achieve the compatibility of the wiring method between MEMS parts and devices, we developed the three-dimensional sputter-evaporation system that coats micropatterned thin copper films on the surface of the MEMS element. The system consists of a process chamber, two branch chambers, the substrate holder, and a linear-rotary motion feedthrough. Thin copper film was sputtered and evaporated on the biocompatible polymer, Pellethane$^{circed{R}}$ and silicone, catheter that is 2 mm in diameter and 700 mm in length. The metal film coating technique with three-dimensional thin film sputter-evaporation system was developed to apply the power and signal lines on the micro active endoscope. In this paper, we developed the three-dimensional metal film sputter-evaporation system operated on the low temperature for the biopolymeric substrates used in the medical MEMS devices.

  • PDF

CASE tool을 이용한 전동차 제어감시장치 (TCMS)의 소프트웨어 설계기법 (Software design technique of Train Control and Monitoring System (TCMS) using CASE tool)

  • 한성호;안태기;김원경;최규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.358-360
    • /
    • 1997
  • The train control and monitoring system(TCMS) is an on board computer system in railway vehicles performing the control, supervisory and diagnostic functions of the complete train. This system replaces a lot of hardwired relays and minimizes the necessaries vehicle wiring thus increasing the reliability of the train. In this paper, we proposed a software design technique of TCMS using CASE tool (SAO+). The TCMS functions are implemented in software easily programmed, using a functional block, graphic programming language. We applied the compressor air module to a case study.

  • PDF

Chemical Mechanical Polishing (CMP) 공정을 이용한 Mutilevel Metal 구조의 광역 평탄화에 관한 연구 (A Study for Global Planarization of Mutilevel Metal by CMP)

  • 김상용;서용진;김태형;이우선;김창일;장의구
    • 한국전기전자재료학회논문지
    • /
    • 제11권12호
    • /
    • pp.1084-1090
    • /
    • 1998
  • As device sizes are scaled down to submicron dimensions, planarization technology becomes increasingly important for both device fabrication and formation of multilevel interconnects. Chemical mechanical polishing (CMP) has emerged recently as a new processing technique for achieving a high degree of planarization for submicron VLSI applications. The polishing process has many variables, and most of which are not well understood. The factors determine the planarization performance are slurry and pad type, insert material, conditioning technique, and choice of polishing tool. Circuit density, pattern size, and wiring layout also affect the performance of a CMP planarization process. This paper presents the results of studies on CMP process window characterization for 0.35 micron process with 5 metal layers.

  • PDF

환축추체 후방 나사고정술 후 생긴 동정맥루 (Arteriovenous Fistula after C1-2 Posterior Transarticular Screw Fixation - Case Report -)

  • 이혁기;조재훈;이성락;강동기;김상철;김용선
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권2호
    • /
    • pp.280-285
    • /
    • 2000
  • Posterior transarticular screw fixation for atlantoaxial instability due to trauma or rheumatoid arthritis provides immediate rigid fixation of the C1-2 vertebral segment while preserving motion between the occiput and C1. This technique provides more resistance to translational and rotational forces than wiring technique. However, the technique of transarticular screw fixation is inherently demanding because of the complex anatomy of the occipitocervical region and vertebral artery(VA) at risk for arterial damage. VA injury may lead to serious subsequent neurological deficits and possibly death from bilateral VA injury. We report a case of a vertebral artery-to-epidural venous plexus fistula after posterior transarticular screw fixation which was treated with balloon occlusion.

  • PDF

중하부 경추손상에서 후방 경추 내고정술 및 골유합술의 분석결과 (Analysis of Posterior Cervical Fixation and Fusion in Subaxial Cervical Spine Injury)

  • 이동훈;송근성
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권12호
    • /
    • pp.1388-1393
    • /
    • 2001
  • Objective : In the retrospective analyzing 19 consecutive patients with subaxial cervical spine(C3~T1) injury treated by posterior cervical fixation and fusion, clinical manifestation, radiologic finding, operative technique, and postoperative results following 6 months were analyzed. Materials and Methods : Most common fracture level was C4-5, mean age 41, and male to female ratio 13 : 6. The most common cause of injury was motor vehicle accident(17 cases). In 19 cervical procedures, interspinous triple wiring was done in 14 cases, lateral mass plating in 5 cases, and additional anterior fusion in 2 cases. Results : Twelve weeks after operation, all cases were reviewed by plain cervical radiogram. In 17 cases that treated by posterior fusion only, 14 cases(81%) had kyphotic angle change less than $5^{\circ}$, 2 cases(12%) $5-20^{\circ}$, and 1 case(6%) more than $20^{\circ}$. Overall fusion rate was 88%, and there was no significant difference of bone fusion rate between autogenous bone graft and allogenous bone graft. Conclusion : In the case of severe posterior column injury or displacement, posterior approach seems superior to anterior approach, but in the case of combined anterior column injury, anterior approach is considered necessary. In this study, posterior fixation and fusion might be acceptable procedure for subaxial cervical fracture and dislocation, owing to its high fusion rate, low kyphotic angulation and low operation related complication rate.

  • PDF

정중 흉골 절개 후 시행한 변형 Robicsek 흉골 봉합법이 수술 후 흉골감염에 미치는 영향 (An Influence of Modified Robicsek Sternal Wiring after Median Sternotomy on the Postoperative Sternal Wound Infection)

  • 장원호;염욱;김동현;오홍철;한정욱;김현조
    • Journal of Chest Surgery
    • /
    • 제42권6호
    • /
    • pp.763-769
    • /
    • 2009
  • 배경: 통상적인 정중 흉골 절개를 이용한 개심술 후 흉골의 불안정성과 흉골 창상 감염은 대부분 동반되어 발생하며 수술 후 경과에 심각한 영향을 끼치게 된다. 본 연구에서는 각기 다른 흉골 봉합 방법을 사용함에 따른 흉골 감염 빈도를 비교하였다. 대상 및 방법: 2004년 4월부터 2008년 12월까지 흉골 절개를 이용한 개심술을 시행 받은 성인 환자 157명을 대상으로 하였다. 이들 중 86명의 A군 환자들은 통상적인 흉골 봉합법을 사용하였고, 나머지 71명의 B군 환자에게는 변형 Robicsek 흉골 봉합법을 사용하였으며. 두 군간의 수술 후 흉골창상 합병증의 빈도에 대해 조사하였다. 결과: 평균 연령은 A군보다 B군이 더 높았다($61{\pm}10$세 vs $57{\pm}13$세). 수술 전 좌심실 구출 율 30% 미만의 좌심실 기능 부전, 만성 폐쇄성 폐질환, 투석이 필요한 신부전 및 당뇨의 빈도가 B군에서 유의하게 높았으나 그 외 수술 전후 감염의 위험 인자는 두 군간에 유의한 차이가 없었다. A군 환자 중 2명에게서 표재성 흉부 창상 감염이 발생하였고 B군에서는 4명의 환자에게서 발생하였으나 통계적 유의한 차이는 보이지 않았다(p=0.255). 그러나 A군 환자들 중 6명의 환자들에게서 흉골 감염이 발생한 반면 B군에서는 한 명도 발생하지 않았으며 이는 유의한 차이를 보였다. 결론: 고위험 환자에게 변형 Robicsek 흉골 봉합법을 사용함으로써 흉골의 안전성을 확보할 수 있었으며, 흉골 감염 빈도가 줄어든 것을 확인할 수 있었다.