• Title/Summary/Keyword: Wiring Device

Search Result 75, Processing Time 0.043 seconds

Analysis for the Thermal Properties of the Electrical Wire according to Overload and Disconnection (과부하 및 물리적 손상(반단선)에 의한 전선의 열적특성 해석)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.26-31
    • /
    • 2007
  • According to the statistical analysis on the electrical fire of 2005 years, most of electrical fire is generated from short circuit(4,985 cases), overcurrent(755 cases) leakage current(391 cases), poor contact(378 cases), disconnection(36 cases) on the electrical wiring device. The researches for the fire hazard about normal electric wiring have already been progressing in the advanced country such as USA and Japan, but Comparative study of the disconnection has not been conducted. Therefore, in this paper, we have simulated the thermal analysis for electrical wire according to deteriorating time in a normal state and disconnection with electrical wire using the electrical-thermal finite element method(Flux 3D). This paper acquire basis data of electricity fire signal by disconnection and wish to help for electrical fire cause diagnosis business.

Detection Technique of Tracking at Indoor Wiring using Neural Net work (신경회로망을 이용한 옥내배선의 트랙킹 검지 기법)

  • 최태원;이오걸;김석순;이수흠;정원용
    • Fire Science and Engineering
    • /
    • v.9 no.1
    • /
    • pp.3-9
    • /
    • 1995
  • This paper is a study to dectect the tracking owing to deterioration of indoor wiring, and to prevent the electrical fire. After analysing the harmonics of waveshapes in load current and tracking current by FFT, a method of identifying the tracking was developed by using neural network. Fluoscent lamp, witch was mostly used in indoor, was chosen as the load used in this study. When the learning number in neural network was more then 30,000 times, an excellent neural net-work which could correctly identify the tracking was established. Therefore, the result of this study can be utilized as a basic material in various measuring instruments, such as an hotline inslation tester, earth tester in vehicles, and tracking fire alarm device, witch can detect the tracking under the condition of hotline.

  • PDF

Application and Example Analysis of Dual DU(Display Unit) of TCMS for rolling stock (철도차량을 위한 TCMS 화면장치의 이중화 적용 및 사례 분석)

  • Lee, Jeung-Sub;Kim, Hoon;Han, Jeong-Soo;Kim, Chul-Ho
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.234-240
    • /
    • 2010
  • Display Unit(DU) of TCMS is very useful device display many data for operation and maintenance graphically. At This Time, rolling stock is reducing the wiring and size of desk for cutting down on their cost and making light weight. Dual Du(Display Unit) of TCMS could make the desk of cab simply by integrating cab's switches and gauges. Dual DU is not only can reduce the wiring and simplify desk of cab but also can making system of TCMS reliable by including backup function each other. For this reason. In this paper, advantages, application and example analysis of Dual DU of TCMS for rolling stock are described through the ongoing projects.

  • PDF

A Human Error-Free Wiring Guide System (휴먼 에러 방지용 배선 안내 시스템 개발)

  • Lee, Hyun Chan;Kim, Joo Han;Kim, Jinsung;Jeong, YeonUk
    • Korean Journal of Computational Design and Engineering
    • /
    • v.22 no.2
    • /
    • pp.181-189
    • /
    • 2017
  • In this paper, we develop a human error-free wire connection guide system. The only related work is Japanese patent by Hitachi. The patent is guiding the wire connection using PC server. And no implementation details have been reported publicly. We propose a new method based on smart mobile devices. The proposed methods are registered as two Korean patents. We implement a prototype wire connection guide system to verify the patents. Through human experiments, we verify the system can reduce the human error more than 90% and speed up the connection process more than twice faster than working without the system. To be used in the industrial fields, the prototype system needs more product packaging works.

Analysis of Electrical and Thermal Signal for Series Arc in Electrical Contact (전선의 접속부에서 직렬아크에 의한 전기적 및 열적 신호 분석)

  • Kim, Doo Hyun;Hwang, Dong Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.1-7
    • /
    • 2015
  • This paper is aimed to analyze the electrical and thermal signal such as ignition possibility, ignition time, thermal characteristics and arc fault power that are associated with electrical fire in case of the occurrence of series arc at IV wiring used for interior wiring at commercial power source. In order to analyze the signal, series arc was induced by generating the constant vibration through vibrating device in the one phase (R phase) and ignition possibility was analyzed along the condition of current value by adding cotton material to the contact point of wiring. The ignition time is shortened as the electric current value increased, burning time is not associated with current value and the temperature rose up to $740^{\circ}C$ though it was not ignited. It was checked out that the temperature was the energy source enough that can generate the fire related with insulation aging of wiring and the inflammable. The possibility of electrical fire by series arc was shown as more than 12% at 5A, more than 42% at 20A and arc showed 27W at 5A, 180W at 20A. It was confirmed that the possibility of electrical fire exists at the condition as above and the circuit breaker did not operate. This data can be used as the reference value for the investigation of electrical fire or development of the circuit breaker.

Study on Design Criteria of HDMI Transmission Line according to Surface Roughness of Printed Circuit Board Wiring Material (인쇄회로기판 배선소재 표면 거칠기에 따른 HDMI 전송선로 설계 기준 연구)

  • Sa, Gi-Dong;Lim, Yeong-Seog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.2
    • /
    • pp.289-296
    • /
    • 2019
  • Recently, the development of smartphone camera technology enables to shoot high quality video. In order to utilize these techniques in various ways, it is necessary to be able to transmit signals to an external device such as a external display. The transmission performance of the video signal is determined by the loss of the transmission line and the length of the wiring. In this paper, we propose the HDMI transmission line design criterion according to the wiring length changed according to the smartphone design and the surface roughness amplitude of the printed circuit board conductor wiring material. Also, we verified the proposed design criteria for the actual smartphone design. The proposed design criterion can be applied to various application fields including high-speed signal transmission line besides mobile application.

Toughnening of Dielectric Material by Thermoplastic Polymer

  • Lee, Jung-Woo;Cho, Jae-Choon;Ra, Seung-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.207-208
    • /
    • 2007
  • Recently, high performance microelectronic devices are designed in multi-layer structure in order to make dense wiring of metal conductors in compact size. Imprint lithography have received significant attention due to an alternative technology for photolithography on such devices. In this work, we synthesized dielectric composite materials based on epoxy resin, and investigated their thermal stabilities and dynamic mechanical properties for thermal imprint lithography. In order to enhance the mechanical properties and toughness of dielectric material, various modified polyetherimide(PEI) was applied in the resin system. Curing behaviours, thermal stabilities, and dynamic mechanical properties of the dielectric materials cured with various conditions were studied using dynamic differential scanning calorimetry (DSC), thermo gravimetric analysis (TGA), and Universal Test Method (INSTRON).

  • PDF

Modifications of RC/TS(Resonant Column and Torsional Shear) Device for the Large Strain (대변형율 시험을 위한 공진주 비틂전단 시험기의 수정)

  • Bae, Yoon-Shin
    • International Journal of Highway Engineering
    • /
    • v.10 no.3
    • /
    • pp.1-10
    • /
    • 2008
  • Conventional RC/TS(resonant column and torsional shear) device usesa specimen with an aspect ratio(height-to-diameter) of 2:1 and this generates a maximum shear strain in the sample of about 1.5% at the maximum rotation of the drives system. The objective of this study is to modify RC/TS device to generate higher strain amplitude. The modifications include a new base pedestal to overcome the limitations in the travel of the drive system and modification of coil wiring to increase torque. The effects of the new coil wire on torque in the electro magnetic drive system were evaluated and the application of modified device was illustrated using sand soil.

  • PDF

Networked Intelligent Motor-Control Systems Using LonWorks Fieldbus

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.365-370
    • /
    • 2004
  • The integration of intelligent devices, devices-level networks, and software into motor control systems can deliver improved diagnostics, fast warnings for increased system reliability, design flexibility, and simplified wiring. Remote access to motor-control information also affords an opportunity for reduced exposure to hazardous voltage and improved personnel safety during startup and trouble-shooting. This paper presents LonWorks fieldbus networked intelligent induction control system architecture. Experimental bed system with two inverter motor driving system for controlling 1.5kW induction motor is configured for LonWorks networked intelligent motor control. In recent years, MCCs have evolved to include component technologies, such as variable-speed drives, solid-state starters, and electronic overload relays. Integration was accomplished through hardwiring to a programmable logic controller (PLC) or distributed control system (DCS). Devicelevel communication networks brought new possibilities for advanced monitoring, control and diagnostics. This LonWorks network offered the opportunity for greatly simplified wiring, eliminating the bundles of control interwiring and corresponding complex interwiring diagrams. An intelligent MCC connected in device level control network proves users with significant new information for preventing or minimizing downtime. This information includes warnings of abnormal operation, identification of trip causes, automated logging of events, and electronic documentation. In order to show the application of the multi-motors control system, the prototype control system is implemented. This paper is the first step to drive multi-motors with serial communication which can satisfy the real time operation using LonWorks network.

  • PDF

FPGA Design of Automatic Checking System for Wiring Harness (하네스 배선의 검사 자동화 시스템을 위한 FPGA 설계)

  • Ryoo, Hwangyu;Kim, Jinyoung;Ryoo, Kwangki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.558-559
    • /
    • 2018
  • The harness wiring serves as an intermediary for transmitting the electrical signals necessary to drive the vehicle and is highly influenced by vehicle performance. Wire harness tester performs assembly test. Harness products are operated with the function of checking 0 and 1. Proceed to inspection in wire assembly process. There is a defect in the finished vehicle during use. We want to improve such defects. We design the FPGA and propose the measurement device design and the simulation result that the line and the line are disconnected by ADC precision harness inspection.

  • PDF