• Title/Summary/Keyword: Wire-to-wire Electrode

Search Result 199, Processing Time 0.023 seconds

Design of Compression Pants for Wireless sEMG Monitoring using e-textile (E-textile을 이용한 무선 sEMG 모니터링 컴프레션 바지 설계)

  • Heejae Jin;Hyojeong Lee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.1
    • /
    • pp.94-107
    • /
    • 2024
  • This study developed compression pants with excellent wearability and signal quality by approaching the design of wireless sEMG monitoring pants from the perspective of technical design, including the evaluation of wearability and the stable wireless transmission of signals through electrode and circuit design, and using e-textiles. An electrode, sewn with silver thread and a circuit stitched in a zigzag pattern using stainless steel wire, were applied. Additionally, polyurethane sealing tape was used to enhance adherence to the skin and reduce electrical resistance. Conductive snaps completed the design, allowing attachment and detachment to the bio-signal acquisition mainboard. Through the subjects' evaluation, it was determined that the final pants were applied with a pattern reduction rate of 25% to provide superior comfort according to different body parts while also minimizing skin irritation around the thigh circuit. The final pants for wireless sEMG monitoring, which demonstrated stable transmission of wireless measurements, was positively evaluated in terms of cognitive acceptability. This study is significant in that it achieved an optimal design by considering both technical aspects and the electrical characteristics of bio-signal monitoring garments, as well as the wearer's perception when designing smart wear.

Influence of Conducting Particle on the Breakdown Phenomena of $SF_6$ gas in Gas Insulated System ([$SF_6$] 가스 절연기기내에 도전성 금속이물 존재시 섬락전압에 미치는 영향)

  • Lee, B.W.;Ham, G.H.;Kim, I.S.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1687-1689
    • /
    • 1998
  • In this work, the behaviours of conducting wire type particles within the coaxial electrode gap energized with high ac voltage have been systematically investigated using charge simulation method. For this, spheroidal charge is adopted as a image charge for the CSM analysis in order to calculate the acquired charge of the particles which are erected on the surface of the outer electrode. For this purpose, the effects of the lengths and diameters of Cu, Al particles in gas insulated system have been studied by a numerical computation and particle lifting voltage, lifting field, breakdown voltage, acquired charge and travelling distance have been considered. From this, we understand that the particle behaviours have different characteristics according to the particle lengths and diameters. And a possible countermeasure, based on the proposed simulation, has been provided with a view to estimating the flashover voltage of $SF_6$ gas under the 1 atm.

  • PDF

Recent Trends in Development of Ag Nanowire-based Transparent Electrodes for Flexible·Stretchable Electronics (유연·신축성 전자 소자 개발을 위한 은 나노와이어 기반 투명전극 기술)

  • Kim, Dae-Gon;Kim, Youngmin;Kim, Jong-Woong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.1
    • /
    • pp.7-14
    • /
    • 2015
  • Recently, advances in nano-material researches have opened the door for various transparent conductive materials, which include carbon nanotube, graphene, Ag and Cu nanowire, and printable metal grids. Among them, Ag nanowires are particularly interesting to synthesize because bulk Ag exhibits the highest electrical conductivity among all metals. Here we reviewed recently-published research works introducing various devices from organic light emitting diode to tactile sensing devices, all of which are employing AgNW for a conducting material. They proposed methods to enhance the stretchability and reversibility of the transparent electrodes, and apply them to make various flexible and stretchable electronics. It is expected that Ag nanowires are applicable to a wide range of high-performance, low-cost, stretchable electronic devices.

Measurement of suction air amount at reciprocating engine under stationary and transient operation

  • Kubota, Yuzuru;Hayashi, Shigenobu;Kajitani, Shuichi;Sawa, Norihiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1037-1042
    • /
    • 1990
  • The air-fuel ratio of an internal combustion engine must be controlled with accuracy for the improvements of exhaust emission and fuel consumption. Therefore, it is necessary to measure the exact instantaneous amounts of fuel and suction air, so we carried out the experiments for measuring the air flow velocity in a suction pipe of an internal combustion engine using three types of instantaneous air flowmeter. The results obtained can be summarized as follows: (1) The laminar-flow type flowmeter is able to measure both the average and the instantaneous flow rate, but it is necessary to rectify the pulsating air flow in the suction pipe. (2) The a spark-discharge type flow velocity meter is able to measure the instantaneous air velocity, but it is necessary to choose the suitable electrode form and the spark character. (3) The tandem-type hot-wire flow velocity meter indicates the instantaneous flow velocity and its flow direction.

  • PDF

Development of Dipstick-Gage-Type Small Sensor Equipped with Individual Control Circuit for Detecting Engine Oil Deterioration (전용제어회로를 적용한 딥스틱게이지형 소형 엔진열화감지센서 개발)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.29 no.3
    • /
    • pp.143-148
    • /
    • 2013
  • In this study, several sensor parts used to obtain better signal stability are designed, a separate control circuit for the sensor is developed, and the results obtained using this control circuit are analyzed. The capacitances of the whole sensor system are measured using the control circuit connected to an improved flexible printed circuit board and an asymmetric dual sensor coated with a ceramic material. To realize good discrimination for a small change in the measured capacitance as the engine oil deteriorates, a commercial application-specific integrated circuit is installed on the control circuit as a capacitance-to-digital converter. The absolute error of a measured signal is found to be approximately ${\pm}4fF$.

Spray Characteristics of Electrostatic Pressure-Swirl Nozzle for Burner Application

  • Laryea, Gabriel Nii;No, Soo-Young
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.16-23
    • /
    • 2002
  • Electrostatic pressure-swirl nozzle for practical oil burner application has been designed. The charge injection method has been used in this design, where the nozzle consists of a sharp pointed tungsten wire as a charge injector and the nozzle body grounded. The spray characteristics of the nozzles have been investigated by using an insulating liquid, i.e. kerosene without active surface agent. Breakup length of liquid decreased with an increase in applied voltage and injection pressure, while the spray angle increased with an increased in both applied voltage and injection pressure. An empirical equations have been suggested to predict the breakup length for electrostatic pressure-swirl atomizer. The experimental result was within the range of the predicted equations. The SMD decreased between the ranges of 2.8 ${\sim}$ 33% when the conventional nozzle was compared to the electrostatic with -10 kV applied to the electrode at a radial distance from 5 to 20 mm.

  • PDF

$NO_x$ Measurement of Exhaust Gas plasma by Laser Induced Fluorescence Spectroscopy (배기가스 플라즈마에서의 레이저유기형광법(LIF)에 의한 $NO_x$ 계측)

  • 전용우;하장호;박원주;이광식;최상태;윤영대
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.95-98
    • /
    • 1999
  • This paper describes preliminary discussions on spatial distribution of NO density, which is mostly contained in simulated NOX exhaust, between a wire-cylinder geometry discharge gaps by using Laser Induced Fluorescence(LIF) Spectroscopy. Spatial distribution of NO density will be measured with varying NO concentrations from 166 to 644[ppm] and diameters of central electrode from 6 to 10mm. Pulsed Nd:YAG laser, Optical Parametric Oscillator(OPO), and Frequency Doubler are used to excite NO molecules to their excited state.

  • PDF

NOx Measurement of Diesel Exhaust Gas by Laser Induced Fluorescence (디젤배기가스의 레이저유기형광법에 의한 NOx 계측)

  • Jun, Yong-Woo;Choe, Joon-Yeong;Ha, Chang-Ho;Park, Won-Zoo;Lee, Kwang-Sik;Choi, Sang-Tae;Youn, Young-Dae
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2256-2258
    • /
    • 1999
  • This paper describes preliminary discussions on spatial distribution of NO density, which is mostly contained in simulated NOx exhaust, between a wire-cylinder geometry discharge gaps by using Laser Induced Fluorescence(LIF) Spectroscopy, Spatial distribution of NO density will be measured with varying NO concentrations from 166 to 644 [ppm] and diameters of central electrode from 6 to 10mm. Pulsed Nd:YAG laser. Optical Parametric Oscillator(OPO), and Frequency Doubler are used to excite NO molecules to their excited state.

  • PDF

Implantable Functional Electrical Stimulation with Inductive Power and Data Transmission System (유도전력전송방식의 이식형 기능적 전기자극)

  • Lee, Joon-Ha
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.97-106
    • /
    • 2007
  • Functional electrical stimulation (FES) has developed over the last 35 years to become a scientifically, technologically and clinically recognized field of interest in clinical medicine. FES has been applied to locomotion, grasping, ventilation, incontinence, and decubitus healing. However, all of these achievements illustrate the initial applications of FES; its true potential has not yet been realized. Recently, FES systems, which are miniaturized stimulation devices, have been utilized in the clinical setting. However, because the stimulating electrodes of the current FES devices are percutaneous electrodes, which are susceptible to wire breakage, and skin infection an implantable FES stimulating electrode has been introduced in the U.S. and Japan. In the present study, an external power supply method using radio frequency (RF) coupling and data transmission was developed for the control of the implantable FES device. In addition, we review the current understanding of FES devices and their application in clinical medicine.

  • PDF

PLASMA THIN FILMS PREVENTING CHLORIDE LONS FROM INTERFERING WITH THE NERNSTIAN pH-RESPONSE OF PLATINUM ELECTRODE SURFACE

  • Yajima, Tastuhiko
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.678-682
    • /
    • 1996
  • The plasma-deposited polymer thin films at platinum surface were investigated as materials blocking access of chloride ions to the platinum surface and preventing their interference with the Nernstian responce of platinum. In the presence of chloride ions, the pH response of a naked platinum was remarkably affected. By comparison of pH responses of coated and uncoated platinum-wire electrodes immersed in solutions with chloride ions, it was found that toluene and ethylbenzene plasma films could improve the pH response of platinum. The pH response of coated platinum electrodes may be explained by the ability of protons, by virtue of their small size, to move through the polymer matrix to the platinum surface.

  • PDF