Fluid Flow Resistance in a Channel with Wire-screen Baffles (와이어 스크린 배플이 설치된 채널에서의 유체유동 저항)

  • Oh, S.K.;Ary, B.K.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.13 no.2
    • /
    • pp.36-41
    • /
    • 2009
  • An experimental investigation was conducted to examine the fluid flow resistance in the rectangular channel with two inclined wire screen baffles. Two different types of wire screens; dutch weave and plain weave, were used as baffle devices in this experiment. Three kinds of baffles with different mesh specifications were made up of dutch type and four different kinds of baffles were made up of plain weave type. The stainless steel wire screen baffles were mounted on the bottom wall with varied angle inclination. Reynolds numbers were varied from 23,000 to 57,000. Results show that the mesh number of baffles plays an important role on friction factor behaviour. It is found that the baffle with the most number of meshes (type SA) has the highest fluid flow resistance.

  • PDF

The Study on The Heat Transfer Enhancement Using Wire Mesh in Impinging Jet System (충돌분류계에서 WIRE MESH를 이용한 열전달 증진에 관한 연구)

  • Kum, S.M.;Kim, D.C.;Yoo, J.O.;Lee, C.E.;Yim, C.S.
    • Solar Energy
    • /
    • v.17 no.1
    • /
    • pp.47-58
    • /
    • 1997
  • The objective of this research was to investigate the enhancement of heat transfer by wire mesh in impinging air jet system at the potential core region. The first experiment was carried out without mesh between nozzle exit and flat plate and the second experiment was done with mesh between them. When mesh was installed in front of the plate, heat transfer has been Increased due to the acceleration between rectangular halls and divided small jet In case clearances are changed, heat transfer comes to maximum under the condition of C=1mm, irrespective of nozzle exit velocity and H/B. Also the average heat transfer enhancement rate of a flat plate with mesh has been increased about 44% at maximum under the condition of U=18m/s, H/B=2 and C=1mm, compared to the result of a flat plate without mesh.

  • PDF

Structural performance of ferrocement beams reinforced with composite materials

  • Shaheen, Yousry B.I.;Eltaly, Boshra A.;Abdul-Fataha, Samer G.
    • Structural Engineering and Mechanics
    • /
    • v.50 no.6
    • /
    • pp.817-834
    • /
    • 2014
  • An experimental program was designed in the current work to examine the structural behavior of ferrocement beams reinforced with composite materials under three point loadings up to failure. The experimental program comprised casting and testing of twelve ferrocement beams having the dimensions of 120 mm width, 200 mm depth and 1600 mm length. The twelve beams were different in the type of reinforcements; steel bars, traditional wire meshes (welded and expanded wire meshes) and composite materials (fiberglass wire meshes and polypropylene wire meshes). The flexural performances of the all tested beams in terms of strength, ductility, cracking behavior and energy absorption were investigated. Also all the tested beams were simulated using ANSYS program. The results of the experimental tests concluded that the beam with fiber glass meshes gives the lowest first crack load and ultimate load. The ferrocement beam reinforced with four layers of welded wire meshes has better structural behavior than those beams reinforced with other types of wire meshes. Also the beams reinforced with metal wire meshes give smaller cracks width in comparing with those reinforced with non-metal wire meshes. Also the Finite Element (FE) simulations gave good results comparing with the experimental results.

Design of Elliptical Gears for Wire Cutting (타원형 기어의 와이어커팅을 위한 설계)

  • Lee, Sung-Chul
    • Tribology and Lubricants
    • /
    • v.23 no.4
    • /
    • pp.149-155
    • /
    • 2007
  • The CAD model of a elliptical gear for wire cutting has been developed. The rolling contact of pitch ellipses whose rotation axes coincide with their focus has been analyzed, and the perimeter of the pitch ellipse has been divided into equal-length segments by the number of teeth. A master tooth profile, which is a composite curve of circular arcs that represents involute, has been introduced. The elliptical gear has been designed by imposing the master tooth on the divided points of the pitch ellipse, and a full fillet has been achieved between neighbour teeth. Thus, the whole profile of an elliptical gear is a composite curve of arcs only, and consequently NC codes for wire cutting can be easily generated. Furthermore, a computer simulation program is developed to verify the mesh of the elliptical gear.

Fabrication of a Superhydrophobic Water-Repellent Mesh for Underwater Sensors

  • An, Taechang
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.100-104
    • /
    • 2013
  • A superhydrophobic mesh is a unique structure that blocks water, while allowing gases, sound waves, and energy to pass through the holes in the mesh. This mesh is used in various devices, such as gas- and energy-permeable waterproof membranes for underwater sensors and electronic devices. However, it is difficult to fabricate micro- and nano-structures on three-dimensional surfaces, such as the cylindrical surface of a wire mesh. In this research, we successfully produced a superhydrophobic water-repellent mesh with a high contact angle (> $150^{\circ}$) for nanofibrous structures. Conducting polymer (CP) composite nanofibers were evenly coated on a stainless steel mesh surface, to create a superhydrophobic mesh with a pore size of $100{\mu}m$. The nanofiber structure could be controlled by the deposition time. As the deposition time increased, a high-density, hierarchical nanofiber structure was deposited on the mesh. The mesh surface was then coated with Teflon, to reduce the surface energy. The fabricated mesh had a static water contact angle of $163^{\circ}$, and a water-pressure resistance of 1.92 kPa.

Performance of a Latent Heat Storage System Using Two-Phase Closed Thermosyphon(II) - The Case of Constant Temperature Heating Fluid (열싸이폰을 이용한 잠열축열시스템의 성능실험(II) - 일정한 온도의 가열유체를 사용한 경우 -)

  • Kim, Tae-Il;Kim, Ki-Hyun
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.37-46
    • /
    • 1992
  • An experimental study was carried out to investigate the performance of a latent heat storage system using paraffin wax as the phase change material. A thermosyphon was employed to transfer heat from the hot ethylene glycol flowing across the evaporator section of the thermosyphon into the wax. In order to increase the effective thermal conductivity of wax, layers of copper wire mesh were immersed in the wax. Experiments were run for volume ratios of 2%, 3%, and 4%, varying mass flow rate of ethylene glycol in each case. Some of the important results are as follows : (1) The wire mesh enhanced the conductive hea transfer and thus, helped even out the temperature distribution in the wax : (2) The increase of the number of layers of wire mesh increased the conduction. However, it also resulted in increasing the resistance to the convective motion of liquefied wax : and (3) There is an optimal number of layers of wire mesh, maximizing the performance of the storage system, which occurred at a volume ratio of $3{\sim}4%$ in the present study.

  • PDF

Performance of a Latent Heat Storage System Using Two-Phase Closed Thermosyphon(I) - the Case of Constant Heat Input - (열싸이폰을 이용한 잠열축열시스템의 성능실험(I) - 열주입량이 일정한 경우 -)

  • Kim, Tae-Il;Kim, Ki-Hyun
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.28-36
    • /
    • 1992
  • The performance of a latent heat storage system using a thermosyphon as the heat transfer device between the heat source and the phase change material was investigated experimentally. In order to increase the effective conductivity of the phase change material, layers of copper wire mesh were immersed in the paraffin wax(Sunoco P-116) in such a way that they also may be considered as fins of the thermosyphon. The important results are as follows : (1) The void space of the wire mesh allowed the convection to occur, thus enhanced the performance of the system : (2) The increase of the number of layer of wire mesh increased the conduction heat transfer. However, it also had adverse effect of subduing convective motion of liquid wax : and (3) Overall heat transfer coefficient and thermosyphon conductance increased with the increase of the number of layer of wire mesh, whereas the heat transfer coefficient between the thermosyphon and the wax decreased.

  • PDF

Study on Temperature Distribution in Cold Storage of Korean Garlic in Wire Mesh Pallet Container Using CFD Analysis (CFD 해석을 이용한 철망 파렛트 컨테이너 적입 마늘의 저온 저장고내 온도 분포 연구)

  • Dong-Soo Choi;Yong-Hoon Kim;Jin-Se Kim;Chun-Wan Park;Hyun-Mo Jung;Jong-Min Park
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.3
    • /
    • pp.195-201
    • /
    • 2023
  • Garlic (Allium sativum)is a major crop in most Asian countries, and its consumption in Asia-Pacific countries exceeds 90% of the global consumption. It contains beneficial ingredients and numerous essential nutrients, such as manganese, vitamin B6, and vitamin B1. Garlic demand is rising not only in Asian countries but also around the world. Particularly, garlic demand has been steadily increasing in European countries, such as Spain, France, Italy, and the American continent. In South Korea, 331,671 tons and 387,671 tons of garlic was produced in 2018 and 2019, respectively, making the country the fifth ranking garlic producer in the world, and the production has been increasing every year. In this study, the study on temperature distribution in cold storage of Korean garlic in folding wire mesh pallet container using CFD (Computational Fluid Dynamics) analysis was performed and Computations were based a commercial simulation software (ANSYS Workbenh Ver. 18.0). Considering the respiration heat of garlic, the decreasing rate of temperature in the area in contact with the cold air was fast due to the inflow of cold air inside, while the decreasing rate of temperature in the center of the pallet was very low. In order to maintain a uniform temperature distribution inside the agricultural product storage pallet in a low-temperature warehouse, it is considered desirable to install an air passageway to allow low-temperature air to flow into the wire mesh pallet.

Retrofitting of exterior RC beam-column joints using ferrocement jackets

  • Bansal, Prem Pal;Kumar, Maneek;Dar, Manzoor Ahmed
    • Earthquakes and Structures
    • /
    • v.10 no.2
    • /
    • pp.313-328
    • /
    • 2016
  • Beam-column joints are recognized as one of the most critical and vulnerable zones of a Reinforced Concrete (RC) moment resisting structure subjected to seismic loads. The performance of the deficient beam-column joints can be improved by retrofitting these joints by jacketing them with varied materials like concrete, steel, FRP and ferrocement. In the present study strength behavior of RCC exterior beam-column joints, initially loaded to a prefixed percentage of the ultimate load, and retrofitted using ferrocement jacketing using two different wrapping schemes has been studied and presented. In retrofitting scheme, RS-I, wire mesh is provided in L shape at top and at bottom of the beam-column joint, whereas, in scheme RS-II along with wire mesh in L shape at top and bottom wire mesh is also provided diagonally to the joint. The results of these retrofitted beam-column joints have been compared with those of the controlled joint specimens. The results show an improvement in the ultimate load carrying capacity and yield load of the retrofitted specimens. However, no improvement in the ductility and energy absorption has been observed.

An Experimental Study on Turbulent Characteristics in the Wake of Mesh-Screens (메쉬 스크린 후류의 난류유동 특성에 관한 실험적 연구)

  • 강신형;이현구;전우평
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.274-284
    • /
    • 1991
  • Mean flows and Reynolds stresses through circular and elliptic wire-mesh screens in the wind tunnel are measured by using the hot-wire system, and flow structures are investigated. Flow in the core of the wake are nearly uniform and the shear layer is developed along the edge of the screen The turbulent kinetic energy in the core decreases at the fast rate. However turbulence components are not in local equilibrium in the shear layer. The shear layer of the circular screen develops outward according to the radial mean motion. On the other hand, 3-dimensional transverse mean motion was turned to the main mechanism for the elliptic shape of the wake to be circular at the downstream.