• Title/Summary/Keyword: Wire Control

Search Result 931, Processing Time 0.032 seconds

Fabrication and Characterization of Bi-axial Textured Conductive Perovskite-type Oxide Deposited on Metal Substrates for Coated Conductor. (이축 배향화된 전도성 복합산화물의 금속 기판의 제조와 분석)

  • Sooyeon Han;Jongin Hong;Youngah Jeon;Huyong Tian;Kim, Yangsoo;Kwangsoo No
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.235-235
    • /
    • 2003
  • The development of a buffer layer is an important issue for the second -generation wire, YBCO coated metal wire. The buffer layer demands not only on the prohibition of the reaction between YBCO and metal substrate, but also the proper lattice match and conductivity for high critical current density (Jc) of YBCO superconductor, In order to satisfy these demands, we suggested CaRuO3 as a useful candidate having that the lattice mismatches with Ni (200) and with YBCO are 8.2% and 8.0%, respectively. The CaRuO3 thin films were deposited on Ni substrates using various methods, such as e-beam evaporation and DC and RF magnetron sputtering. These films were investigated using SEM, XRD, pole-figure and AES. In e-beam evaporation, the deposition temperature of CaRuO3 was the most important since both hi-axial texturing and NiO formation between Ni and CaRuO3 depended on it. Also, the oxygen flow rate had i[n effect on the growth of CaRuO3 on Ni substrates. The optimal conditions of crystal growth and film uniformity were 400$^{\circ}C$, 50 ㎃ and 7 ㎸ when oxygen flow rate was 70∼100sccm In RF magnetron sputtering, CaRuO3 was deposited on Ni substrates with various conditions and annealing temperatures. As a result, the conductivity of CaRuO3 thin films was dependent on CaRuO3 layer thickness and fabrication temperature. We suggested the multi-step deposition, such as two-step deposition with different temperature, to prohibit the NiO formation and to control the hi-axial texture.

  • PDF

Effects of the Tagging methods on the Growth and Survival of Abalone Juvenile, Haliotis discus hannai (전복, Haliotis discus hannai 치패의 성장과 생존에 미치는 표지의 영향)

  • Kim Bong Seok;Lee Yun Ho;Park Doo Won
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.3
    • /
    • pp.282-288
    • /
    • 2002
  • This study was carried out to investigate the optimum tagging method of the abalone juvenile, Haliotis discus hannai in indoor culture system from May 2000 to January2001. Tagging methods were shell drilling, copper-wire tagging at the respiratory pore and nut gluing on the shell. The attachment rates of the shell showed high in the 2- and 3 cm bolt-nut tagged groups, about over $89.5\%$, whereas shell drilling groups on the shell were about $18.5\%$. The internal coating rates tagged with bolt-nut were over $96.6\%$, while those tagged with copper wire were less than $17.1\%$. Growths in the all marked and tagged experimental groups comparing with control groups were not significantly different (p>0,05). Survivals in all tagging groups except shell drilling and nut gluing groups in the 5 cm abalone were over $95\%, Accordingly, all juvenile groups were not affected by the tagging methods in terms of the growth and survival on the abalones. Based on these results, the micro bolt-nut tagging was the most effective method in abalone.

Studies on Silk Reeling Tension Control (생사의 조사장력관리에 대한 연구)

  • 최병희;정동웅
    • Journal of Sericultural and Entomological Science
    • /
    • v.15 no.2
    • /
    • pp.35-43
    • /
    • 1973
  • Since automatic silk reeling machine has been used in the fold, silk reeling tension has been considered to be an important matter. Such silk reeling tension affects on the physical nature of silk which would be Wire Silk in case of super high reeling velocity. This will be a report regarding with the silk reeling tension used Korean cocoon and various analyses are carried out where reached to following results. 1. Korean silk is still far from Wire Silk yet produced as general silk. 2. There is more possibility to increase silk reeling velocity if cocoon nature is improved. 3. At present, it is considered that the optimum reeling velocity is to be about 190 r.p.m. which is corresponded with 0.4∼0.5 g/d silk reeling tension. 4. This report has prepared a silk reeling tension contolling diagram against reeling velocity as shown at Figure 7. The mathematical relations between them are; A. in case of total silk reeling tension; Y=5.0831+0.0381X(Y; total reeling tension, g/21d, X; reeling velocity, m/min) B. in case of initial silk reeling tension; Y=3.1922+0.0175X (Y; initial reeling tension, g/21d, X; reeling velocity, m/min) 5. The main problems for the increase of silk reeling velocity is considered to be Break Down of Silk Reeling Ends caused by Cocoon Jumping or Cocoon Layer Seperation during the silk reeling work. Such troubles are concerned with the produced cocoon nature.

  • PDF

THE DEVELOPMENT OF INDWELLING WIRELESS PH TELEMETRY OF INTRAORAL ACIDITY (구강 내 산도의 생체 내 측정을 위한 wireless pH telemetry의 개발)

  • Kim, Hyung-Jun;Kim, Jae-Moon;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • The purpose of this study was to develop the wireless pH telemetry lasting longer than 24 hours in the mouth to overcome the limits of conventional wire telemetry previously used for salivary and plaque pH measurement, and to assess its effectiveness. We developed a wireless pH telemeter which can measure and store the pH profile data during more than 24 hours. It was composed of intraoral part; pH sensor of antimony electrode, battery and microprocessor for data storage, and extraoral part; control/data receiver and data analyzing software which was newly made for this device. After inspecting wireless electrode for accurate measurement, it was attached to the removable intraoral appliance and delivered to the volunteer who was told to wear except brushing time, retrieved after 24 hours and finally the pH profile data was extracted and analyzed. When compared with conventional wire telemetry, this device showed similar results and induced less discomfort to examinees. The data showed pH changes at same time when examinees ate various scheduled foods and beverages. With this method it became possible to accurately measure pH changes within mouth for long time in accordance with individual's lifestyle, definitely reducing the discomfort inflicted to the examinees' life.

  • PDF

Three-dimensional finite element analysis on the effect of maxillary incisor torque (상악 절치부-토크에 의한 치아 이동과 응력 분포에 관한 유한요소법적 연구)

  • Yoon, Hyun-Joo;Lim, Yong-Kyu;Lee, Dong-Yul;Jo, Yung-Soo
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.137-147
    • /
    • 2005
  • The purpose of this study was to investigate the stress distribution in the periodontal tissue and the displacement of teeth when active torque was applied to the maxillary incisors by three-dimensional finite element analysis A three-dimensional finite element model consisted of the maxillary teeth and surrounding periodontal membrane, $.022{\times}.028$ Roth prescription bracket and stainless steel, NiTi and TMA rectangular ideal arch wires which were modeled by hexahedron elements. Applied active torques were 2, 5 and 10 degrees ThHe findings of this study showed that the reaction force acting or the bracket was the extrusion force on the mesial side of the incisors and canine and the intrusion force on the distal side of the incisors and canine. The amount of force and moment was greatest at the lateral incisor. When active anterior labial crown torque was applied. labial crown and distal tipping and Intrusion of the incisors took place. and lingual crown distal tipping and extrusion of the canine occured. An excessive force was concentrated on the lateral incisor, when the stainless steel wire was used NiTi or TMA wire is desirable for torque control.

Line Tracking Method of AGV using Sensor Fusion (센서융합을 이용한 AGV의 라인 트레킹 방법)

  • Jung, Kyung-Hoon;Kim, Jung-Min;Park, Jung-Je;Kim, Sung-Shin;Bae, Sun-Il
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.1
    • /
    • pp.54-59
    • /
    • 2010
  • This paper present to study the guidance system as localization technique using sensor fusion and line tracking technique using virtual line for AGV(autonomous guided vehicle). An existing AGV could drive on decided line only. And representative guidance systems of such guidance system are magnet-gyro guidance and wired guidance. However, those have had the high cost of installation and maintenance, and the difficulty of system change according to variation of working environment. To solve such problems, we make the localization system which is fused with a laser navigation and gyro, encoder. The system is robust against noise, and flexible according to working environment through sensor fusion. For line tracking of laser navigation without wire guidance, we set the virtual line in program, and design the driving controller based on difference of angle and distance between AGV's position and decided virtual line. To experiment, we use the AGV which is made by ourselves, and experiment the line tracking repeatedly on same experimental environment. In result, maximum distance error between decided virtual line and AGV's position was less than 49.93mm, and we verified that the proposed system is efficient for line tracking of actual AGV.

Flight Envelope Load Factor Limit Logic Design for Helicopter Fly-By-Wire Controller (전자식 조정장치 헬리콥터의 하중 비행영역 제한 로직 설계)

  • Choi, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.159-164
    • /
    • 2016
  • This paper reports the load factor logic design for a fly-by-wire helicopter flight envelope protection. As a helicopter is very complex system with a rotor, fuselage, engine, etc., there are many constraints on the flight region. Because of these constraints, pilots should consider them carefully and have a heavy workload, which causes controllability degradation. In this respect, automatic logic is needed to free the pilot from these considerations. As one of these logics, the flight envelope protection logic for the load factor of a FBW helicopter was designed. The flight to exceed the load factor is caused by an abrupt pitch cyclic stick change. In this scheme, the load factor limit logic was added between the pilot stick command block and pitch attitude command block. From the current load value, the available attitude range was calculated dynamically and simulated on the helicopter simulator model to verify the performance. A comparison of the simulation results at the hovering and forward speed region with and without applying the load limiting logic showed that the load factor limit was exceeded more than 20% when the logic was not applied, whereas with the load factor limit logic the load factor was within the limit. In conclusion, a dynamically allocated limitation logic to helicopter FBW controller was verified by simulation.

Simulation Study of a Large Area CMOS Image Sensor for X-ray DR Detector with Separate ROICs (센서-회로 분리형 엑스선 DR 검출기를 위한 대면적 CMOS 영상센서 모사 연구)

  • Kim, Myung Soo;Kim, Hyoungtak;Kang, Dong-uk;Yoo, Hyun Jun;Cho, Minsik;Lee, Dae Hee;Bae, Jun Hyung;Kim, Jongyul;Kim, Hyunduk;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.31-40
    • /
    • 2012
  • There are two methods to fabricate the readout electronic to a large-area CMOS image sensor (LACIS). One is to design and manufacture the sensor part and signal processing electronics in a single chip and the other is to integrate both parts with bump bonding or wire bonding after manufacturing both parts separately. The latter method has an advantage of the high yield because the optimized and specialized fabrication process can be chosen in designing and manufacturing each part. In this paper, LACIS chip, that is optimized design for the latter method of fabrication, is presented. The LACIS chip consists of a 3-TR pixel photodiode array, row driver (or called as a gate driver) circuit, and bonding pads to the external readout ICs. Among 4 types of the photodiode structure available in a standard CMOS process, $N_{photo}/P_{epi}$ type photodiode showed the highest quantum efficiency in the simulation study, though it requires one additional mask to control the doping concentration of $N_{photo}$ layer. The optimized channel widths and lengths of 3 pixel transistors are also determined by simulation. The select transistor is not significantly affected by channel length and width. But source follower transistor is strongly influenced by length and width. In row driver, to reduce signal time delay by high capacitance at output node, three stage inverter drivers are used. And channel width of the inverter driver increases gradually in each step. The sensor has very long metal wire that is about 170 mm. The repeater consisted of inverters is applied proper amount of pixel rows. It can help to reduce the long metal-line delay.

Yangkyuksanhwa-Tang Attenuates Ischemic Brain Injury in a Focal Photothrombosis Stroke Model (뇌허혈 마우스모델에서 양격산화탕이 뇌 손상 완화에 미치는 효과)

  • Han, Do-Kyung;Pak, Malk-Eun;Kwon, Ok-Sun;Choi, Byung-Tae
    • Journal of Life Science
    • /
    • v.29 no.11
    • /
    • pp.1258-1266
    • /
    • 2019
  • Yangkyuksanhwa-Tang (YKSH), consisting of nine different herbs, is commonly used in Soyangin-type individuals with stroke, based on the Sasang Constitution Theory in Korea. However, no evidence has yet confirmed a beneficial effect of YKSH in ischemic stroke treatment. In this study, we investigated the effects of YKSH on ischemic brain injury in a mouse model of cerebral ischemia. Focal cerebral ischemia in mice was induced by photothrombosis, and behavioral recovery was evaluated. Infarct volume, inflammation, and newly generated cells were evaluated by histology and immunochemistry. YKSH treatment resulted in a significant recovery from the motor impairments induced by focal cerebral ischemia, as determined with wire grip and rotarod tests. YKSH treatment also decreased the infarct volume and the number of cells positive for tumor necrosis factor-${\alpha}$ and myeloperoxidase when compared with a vehicle-treated control group. By contrast, YKSH treatment considerably increased the number of cells positive for glial fibrillary acidic protein and ionized calcium-binding adapter molecule 1, as well as the number of cells doubly positive for Ki67/doublecortin when compared with the vehicle-treated group. These results suggest that YKSH treatment attenuated the infarct size by anti-inflammatory action, astrocyte and microglia activation, and neuronal proliferation, thereby facilitating neurofunctional recovery from a cerebral ischemic assault. YKSH could therefore be a potential treatment for neurofunctional restoration of the injured brains of patients with stroke.

Wireless Bridge Health Monitoring System for Long-term Measurement of Small-sized Bridges (중소교량의 지리적 특성을 고려한 무선 전력 및 통신 기술 기반 교량 장기 계측시스템 구축 방안 연구)

  • Tae-Ho Kwon;Kyu-San Jung;Ki-Tae Park;Byeong-Cheol Kim;Jae-Hwan Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.4
    • /
    • pp.86-93
    • /
    • 2023
  • A bridge health monitoring technology is under development for the safety management of aged bridges. The bridge health monitoring technology has been developed mainly for single bridge management at a large scale, so it uses wire-based systems for power supply and data transfer. However, the wire-based systems need to be improved for the sporadically distributed small-sized bridges on local roads. This study proposed a wireless structural health monitoring system for small-sized bridges. The proposed monitoring system overcomes the limitations of wired systems by providing wireless power through solar power and utilizing LTE technology to transmit measurement data. In addition, a remote control system and power management plan were proposed to ensure the stability of the bridge measurement system. The proposed measurement system was installed on 32 bridges on fields and verified the operability by collecting 80.6% of measurement data for one year. The proposed system can support the health monitoring of aged bridges on local roads.