• Title/Summary/Keyword: Window to floor ratio

Search Result 9, Processing Time 0.019 seconds

The verification about possibility of introducing Window to Floor Ratio as design index for building energy performance

  • Choi, Won-Ki;Lee, Yong-Jun;Lee, Hyun-Soo;Eom, Jae-Yong;Lee, Chung-Kook
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose: Many design index that are using in planning phase have been developed. The most popular things among them are Window to Wall Ratio and Surface to Volume Ratio. However there are some limits. Window to Wall Ratio cannot consider building size and Surface to Volume Ratio cannot do Window to Wall Ratio. Accordingly, in this paper, the Window to Floor Ratio was proposed that it can be considered both building size and Window to Wall Ratio. And analyzed correlation of energy demand. Method: For the test, 16 modules with the size of $6m{\times}6m{\times}4m$ were used to make 35 models with the same volume. The simulation was conducted to 945 cases using the window-to-wall ratio of 30, 50 and 70 % in three areas such as Seoul, Gwangju and Jeju and three kinds of windows. And IES_VE was used. Result: The findings above show that the Window to Floor Ratio that can be considered both building size and Window area have to become as design index. It was found out that design criteria with SHGC is necessary, not with the thermal performance (U-value). It is needed to additional analysis about residential building and the effect of 24-hours heating and cooling condition. It plans to carry out research to establish design indicators for climatic conditions in the country and building applications.

A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance (염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구)

  • Oh, Myung-Hwan;Sim, Se-Ra;Lee, Chul-Sung;Chin, Kyung-Il;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds (실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석)

  • Hyun, In-Tak;Lee, Jae-Ho;Yoon, Yeo-Beom;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.

Daylight Assessment of Venetian Blind by Shading Heights and Slat Angles (베네시안 블라인드의 높이와 슬랫각도 조절에 따른 계절별 실내주광분포 분석)

  • Shin, Hwa-Young;Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.105-111
    • /
    • 2011
  • Aims of this study is to investigate the daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles in the preliminary stage of the parametric study. Floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. Enlarging living area by balcony elimination, the larger glass area of window is exposed to the direct sunlight. As a common sunlight controlling device, blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting. However, blind system can produce discomfort in occupant and less energy efficiency, if it has not been controlled optimally. The simulation model was based on the unit module of typical living space with balcony elimination. The room dimension was $6.0m(w){\times}6.9m(d){\times}2.7m(h)$ with floor to ceiling height of 2.5m. The blind system was simulated at five slat angles (horizontal, $30^{\circ}$, $45^{\circ}$ upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, no-blind) using the Desktop RADIANCE 2.0 program. The series of simulation results indicates that the advantages of available daylight and outside of view can be improved by proper adjusting blind system.

Analysis of the Determinants on the Annual Average Price Rising Rate for Pyeong of Apartment Housing in Seoul (서울지역 아파트 평당 연평균 가격상승률 결정요인 분석)

  • Kil, Ki-Suck;Lee, Joo-Hyung
    • Journal of the Korean housing association
    • /
    • v.18 no.3
    • /
    • pp.63-72
    • /
    • 2007
  • The purpose of this study is to identify the impact of the building, site, and region characteristic factors on the annual average price rising rate of apartment housing in Seoul. The data were consisted of 272 apartment units in Seoul. A survey included checking the drawing documents and interview with apartment maintenance staffs and real estate agencies from October 2006 to February 2007. Data were analyzed with descriptives, frequency, crosstabs, and linear regression by SPSS/PC for Window. The linear regression model was employed to evaluate the price rising rate in apartment housing. Following results were obtained. The price rising rate for pyeong ($3.3m^2$) of apartment housing was determinated by the district zone, the construction company's brand name, the building age, the building stories, the floor space index, the building-to-land ratio, the green space rate, and the distance from the downtown. Especially, the district zone was the most important factor that affected the price rising of apartment housing in Seoul. Therefore, the policy has to focus to solve the imbalance between autonomous districts with the collaborated tax.

A study on the application of BIPV to the Apartment Building (BIPV의 아파트 건물 적용 가능성에 대한 연구)

  • Lee, Eung-Jik
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.25-32
    • /
    • 2006
  • Regarding to the Domestic housing politics to improve residing environment and effective use of country land, apartment buildings have been constructed since early of 1970s. Now apartment is taking over 50% out of entire housing in Korea. In the view point of PV application to the apartment, PV has amny advantages because of the wideness of out-walls and high floors building in APT. Therefore, if APT could use the electricity produced by BIPV, we can solve more easily environment and energy problems caused by housing. The research conclusion by analysing conditions and application method to introduce BIPV application to APT in near future is as below. -The out look of APT has been developed periodically and recently gable roof or canopy is popular which PV installation is more favorable. -For Balcony part with double skin facade sassy window, It has a preferable condition to install on the wall depending on the window direction. -In case of shorter distance between buildings due to high ratio of outside measurement, it is more desirable to install PV on the roof than on the wall of Apartment by considering low solar altitude. -Also depending on the direction of APT building, it is more effective and productive in electricity in the broad surface of side wall of APT. -In case of superhigh floor APT where facade system is mostly double skin facade of curtain wall system, PV module can replace the traditional curtain wall and will reduce architectural materials and obtain various out look design thereof.

The Efficacy of the Graft Materials after Sinus Elevation: Retrospective Comparative Study Using Panoramic Radiography

  • Jeong, Tae Min;Lee, Jeong Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.4
    • /
    • pp.146-153
    • /
    • 2014
  • Purpose: This study compares and evaluates the efficacy of graft materials after maxillary sinus bone grafts with autogenous tooth bone graft material (AutoBT), demineralized freeze-dried bone allograft (DFDBA) and deproteinized bovine bone mineral (DBBM). Methods: The study involved 30 sinuses in 26 patients who visited the Division of Oral and Maxillofacial Surgery, Department of Dentistry in Ajou University Hospital and received either AutoBT, DFDBA or DBBM with sinus elevation using the lateral window technique. Sinus graft height was measured before, immediately after, and six months after bone graft with panoramic radiography and the height changes of the sinus floor was compared according to the graft materials. Results: After six months, the decrease ratio of graft heights were 13.57% for AutoBT group, 14.30% for DFDBA group, and 11.92% for DBBM group. There was no statistically significant difference. Conclusion: The new maxillary sinus floor formed by the upper border of bone graft material, can repneumatize after the maxillary sinus elevation. Thus, long-term stability of sinus graft height represents an important factor for implant success. We found that the three graft materials for sinus elevation do not differ significantly and all three graft materials showed excellent resistance to maxillary sinus repneumatization. However, due to the special circumstances of the maxillary sinus and small sample, the actual difference between the three graft materials may not have been detectable. Therefore further study needs to be conducted for more reliable study results.

A Study on the Design Types and Characteristics of Apartment Entrances - Focus on Whasung Dongtan Apartments - (아파트 동출입구 디자인 유형 및 특성에 관한 연구 - 화성동탄신도시 시범지구 및 1, 2공구 아파트를 중심으로 -)

  • Lee, Ki-Seok
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.184-193
    • /
    • 2009
  • In recent years, the architectural interest in the apartment design has been getting focused on qualitative improvement and design differentiation. Especially the facade design differentiation is one of the most important elements in this matter. The purpose of this study is to provide the basic informations that can be referenced when architects are dealing with exterior design by analyzed design types and characteristics of apartment entrances. Target apartment of this study was whasung dongtan the 2nd phase new city districts which was planned to solve a housing shortage in the capital region. Having examined eleven pilot districts, four 1st construction areas, and eight 2nd construction areas, - total 23 complexes - 282 apartment entrances in 212 apartment buildings were carefully researched. Apartment entrance design can be divided into 15 different design elements: design types and combination types, direction, shape, height, approach types, exterior wall finishes of entrance, exterior wall finishes of lower parts of apartment, handrail types of slope, floor finishes of slope, distribution ratio of piloti, ceiling height of piloti, floor finishes of piloti, space use of piloti, window establishment between piloti and elevator hall, landscape elements of piloti. Design characteristics of building entrances were also analyzed in 4 groups (I, II, III, IV) divided by construction contractors ranking. In conclusion, first, design types and combination types can be classified into 15 different kinds, and the group I and II tend to show wider variety of entrance combinations. Secondly, the height and volume of extrude entrance type tend to increase in the group I and II. Third, the spatial configuration of pilotis appears to show more of 'pass + store + break' rather than 'access', as we get closer to the group I.

Thermal Environment Evaluation of Wooden House Using Infra-red Thermal Image and Temperature Difference Ratio (TDR) (적외선열화상과 온도차비율법을 이용한 목조 주택의 열환경평가)

  • Chang, Yoon-Seong;Eom, Chang-Deuk;Park, Jun-Ho;Lee, Jun-Jae;Park, Joo-Saeng;Park, Moon-Jae;Yeo, Hwan-Myeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.518-525
    • /
    • 2010
  • Infrared (IR) thermography which is the technique for detecting invisible infrared light emitted by objects due to their surface thermal condition and for producing an image of the light has been applied in various field without damaging the objects. It also could be used indirectly to examine the inside of an object. In this study, insulation property of wooden house in Korea Forest Research Institute (KFRI) was evaluated with according to "Thermal performance of building - Quantitative detection of thermal irregularities in building envelopes - infrared method (KS F 2829)". This method uses "Temperature Difference Ratio (TDR)" between outdoor wall surface and indoor wall surface of wooden building for evaluating its thermal performance. The thermal performance of a room on the 2nd floor of the wooden house was focused in this study and IR thermography on the indoor and outdoor surface of the house was captured by IR camera. Heat loss from the corner and the window of the wooden house as well as wall of the house was quantitatively evaluated and the invisible heat loss in the wall was detected. It is expected that the results from this study could contribute to improve the wooden building energy efficiency.