• Title/Summary/Keyword: Window performance

Search Result 1,373, Processing Time 0.026 seconds

Reliability Assessment Criteria of Window switch for automobiles (자동차용 윈도우 스위치의 신뢰성 평가기준)

  • Choi, Man-Yeop;Choi, Beom-Jin;Baik, Jai-Wook
    • Journal of Applied Reliability
    • /
    • v.11 no.1
    • /
    • pp.1-15
    • /
    • 2011
  • Automobile markets are so fierce in the world market that every major manufacturer assure the buyer of the car by give a provocative warranty plan for their cars. For instance Hyundai motor company offer 10 years and 100,000 miles of warranty whichever comes first. But in order for this effort to be successful every critical component such as window switch has to be proven to be reliable in an adverse environment. Therefore, in this article reliability assessment criteria for window switch are established in terms of basic performance test, environment test and life test.

Analysis Performance of Super Window through Simulation and Verification Experiment (시뮬레이션과 실증실험을 통한 슈퍼윈도우의 성능분석)

  • Peak, Sang-Hun;Lee, Jin-Sung;Cho, Soo;Jang, Cheol-Yong;Sung, Uk-Joo;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1069-1074
    • /
    • 2006
  • Heat loss by window in building occupies about 1/4 of energy amount used building. Therefore, high thermal insulation of windows system can speak as very important part in save energy of building. in this research, After select most suitable frame design and Glazing system for high thermal insulation of windows, execute simulation of mixing frame and Glazing System. Also, manufacture windows with the result and execute verification experiment, with verified simulation, this research evaluated thermal insulation performance of window by Glazing System's change.

  • PDF

Study on Estimate of Window Condensation performance Due to Temperature Depreciation Ratio (표면 온도 저하율에 따른 창호부 결로성능 예측에 관한 연구)

  • Sung, Uk-Joo;Cho, Soo;Jang, Cheul-Yong;Lee, Jin-Seong;Peak, Sang-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1255-1260
    • /
    • 2006
  • This present study analyzed temperature depreciation ratio of window inside surface by KS F 2295 'Procedure for determining fenestration product condensation resistance values'. it estimated window indoor surface condensation due to variable environmental condition. Performance of condensation resistance by using temperature depreciation ratio until applied Low-e and Ar glazing improved about 45% from 24 mm clear. Temperature depreciation ratio by KS F 2295 considers analytic index of window condensation due to variable boundary condition.

  • PDF

Research on the Effect of Car Body Design on CFD Aerodynamics Performance (자동차 차체 형태 디자인이 공기역학 성능에 미치는 영향에 대한 연구)

  • Kim, Jeong Min
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.501-506
    • /
    • 2020
  • In this experimental study, we have analyzed aerodynamic performance of the four representative types of passenger car vehicles, different types of side window angles, different types of engine hood angles, and the angle difference of the roof line in order to comprehensively analyze how the aerodynamic performance varies with different shape of vehicle. Experiment results showed that the rear window falling at aa certain angle lowered aerodynamic performance, angle difference of the lowered roof line did not affect aerodynamic performance, and the back window line falling at certain angles had no visible effect on aerodynamic performance. Back window line leaning towards front side may help enhance styling aesthetics, but aerodynamic performance decreased. In case of rear diffuser installation, aerodynamic performance also decreased.

A Study on the Heat Transfer Phenomenon through the Glazing System (창호를 통한 열전달 현상에 관한 연구)

  • Kang, Eun-Yul;Oh, Myung-Won;Kim, Byung-Sean
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.32-37
    • /
    • 2009
  • An energy loss through the window system occupies about 10 to 30 percent on energy consumption of the whole building. That is the reason, several elements for a building composition of window system are the weakest from the heat. Insulation performance increases for the reducing heat loss. Heat transfer through the window system that is reducing heat transfer through conduction, convection and radiation. Insulation performance reinforcement methods classify improving heat specific quality of window system and improving efficiency of whole window system. The most application method among each methods is reducing emission ratio of the window system(Low-E glass), increasing a number of glazing(multiple window) and a method of vacuuming between glazing and glazing. Therefore this study is investigated a sort of glazing and specific character, U-value calculation with changing glazing thickness and calculation of temperature distribution and U-value with a glazing charging gas kind from double glazing. For a conclusion, an aspect of U-value figure at the smallest value case of vacuum glazing with Low-E coating. That means insulation efficiency is the best advantage during a building plan selecting vacuum glazing with Low-E coating for a energy saving aspect. In this way, U-value become different the number of glazing, coating whether or not and selecting injection gas. Therefore selecting of glazing is very important after due consideration by a characteristic and use of building and consideration of strong point and weak point.

  • PDF

Window Attention Module Based Transformer for Image Classification (윈도우 주의 모듈 기반 트랜스포머를 활용한 이미지 분류 방법)

  • Kim, Sanghoon;Kim, Wonjun
    • Journal of Broadcast Engineering
    • /
    • v.27 no.4
    • /
    • pp.538-547
    • /
    • 2022
  • Recently introduced image classification methods using Transformers show remarkable performance improvements over conventional neural network-based methods. In order to effectively consider regional features, research has been actively conducted on how to apply transformers by dividing image areas into multiple window areas, but learning of inter-window relationships is still insufficient. In this paper, to overcome this problem, we propose a transformer structure that can reflect the relationship between windows in learning. The proposed method computes the importance of each window region through compression and a fully connected layer based on self-attention operations for each window region. The calculated importance is scaled to each window area as a learned weight of the relationship between the window areas to re-calibrate the feature value. Experimental results show that the proposed method can effectively improve the performance of existing transformer-based methods.

Analysis of Various Window Effect for SAR image Recovery (SAR image 복구를 위한 Window 적용 효과 연구)

  • Kim, Hyunguk;Koh, Jinhwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.46-54
    • /
    • 2015
  • SAR is a Radar to obtain the video information using a radio wave. Platform emit the radio wave, depending backscattered waves returned from the target object the signal to the distance, to create a topographical map is recorded in two-dimensional image. In this paper, through a simulation to apply a variety of window in the SAR image processing for SAR image recovery is to study the application effect of the window, as a result, at the side of the signal of the SNR, Flattop window to improve the best performance it was confirmed to show.

Study on the Analysis of Energy Consumption Corresponding Window Area Ratio (건물 외피 창호면적 변화에 따른 에너지 소비량에 관한 연구)

  • Ha, Dae-Woong;Park, Kyung-Soon;Son, Won-Tug
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.857-862
    • /
    • 2008
  • Window is the most demanding design component in the building design. Recently, window area in the building surface has been increased significantly in the office building. As window area increased significantly, however, the thermal load has been increased significantly due to lack of thermal performance of the outside wall. In this paper, we discussed the energy consumption of the buildings according to window area ratio. Two types of building for energy consumption analysis were made by Designbuilder v.1.4 and Energyplus v.2.0. Window area ratio was five different types ($30%{\sim}70%$) in each building. As a result, the cooling energy consumption has been decreased as window area decreased in each building. Whereas the heating energy consumption has been increased window area decreased.

  • PDF

Instruction Queue Architecture for Low Power Microprocessors (마이크로프로세서 전력소모 절감을 위한 명령어 큐 구조)

  • Choi, Min;Maeng, Seung-Ryoul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.11
    • /
    • pp.56-62
    • /
    • 2008
  • Modern microprocessors must deliver high application performance, while the design process should not subordinate power. In terms of performance and power tradeoff, the instructions window is particularly important. This is because a large instruction window leads to achieve high performance. However, naive scaling conventional instruction window can severely affect the complexity and power consumption. This paper explores an architecture level approach to reduce power dissipation. We propose a low power issue logic with an efficient tag translation. The direct lookup table (DTL) issue logic eliminates the associative wake-up of conventional instruction window. The tag translation scheme deals with data dependencies and resource conflicts by using bit-vector based structure. Experimental results show that, for SPEC2000 benchmarks, the proposed design reduces power consumption by 24.45% on average over conventional approach.

A Study on Integration of Pre-manufactured Window Systems with Conventional Building Design Elements (자연채광 요소기술 도출을 위한 창호시스템과 건물요소와의 통합화에 관한 연구)

  • Kim, Jeong-Tai;Jeong, In-Young;Jeong, Yu-Gun
    • KIEAE Journal
    • /
    • v.2 no.2
    • /
    • pp.15-22
    • /
    • 2002
  • Importation of mass production of building elements with standardization are vital way for environment-friendly architectural planning, which it makes the lifespan of a building longer than normal with easier maintenance and remodeling. The advantage might be magnified here in Korea since typical types of apartment house are dominated in our construction market. For the purpose, a series of pre-manufactured window systems is one of the optimal elements to be prototype building modules. In the design process of the system windows, lots of consideration should be involved and they include aesthetics, thermal performance, noise reduction, airtightness, and so forth. A real survey on the ready-made window systems has been performed and its optical issue related to luminous peculiarity is what is of major interest in this study. In addition, technical review on more advanced window products and their adaptable potential for the integration with fundamental architectural design elements were carried out.