• 제목/요약/키워드: Window Type Ventilation System

검색결과 23건 처리시간 0.023초

공동주택의 환기성능 개선을 위한 Shaft Box형 발코니의 적용성 검토 (Study on Application of Shaft Box type Balcony for Improvement of Ventilation Performance in Apartment)

  • 노지웅;김곤
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.3-8
    • /
    • 2007
  • Recently, because of the continuous rise of international oil price, energy saving is strongly demanding. So, Ecological technics of architecture such as use of natural energy have been actively explored in the field of building. In the method of utilizing natural energy, the key point is to saving energy effectively as not lowering the comfort of indoor environment, various systems investigated. Many papers about double skin facade system have been reported, it is announced broadly that the system is very effective in improvement of natural ventilation and indoor thermal environment, and also protecting outdoor sound. The shaft box facade is a special form of box window construction. It consists of a system of box windows with continuous vertical shafts that extend over a number of stories to create a stack effect. The facade layout consists of an alternation of box windows and vertical shaft segments. This research investigated the natural ventilation performance of shaft box type balcony which conform the shaft box type double skin to the exiting balcony construction. First, analyzed various types of exiting apartments, proto-type was decided. By using virtual environment Program, modeling the proto-type, compared the contribution of air temperature and the effect of outdoor air cooling. by this research, we confirmed that shaft box type balcony had many possibility for improvement of indoor environment.

공동주택의 하이브리드 환기시스템 성능평가 연구 (A Study on the Performance of the Hybrid Ventilation System for Apartment Houses)

  • 전주영;김길태;김상희
    • 토지주택연구
    • /
    • 제3권1호
    • /
    • pp.89-96
    • /
    • 2012
  • 본 연구는 공동주택에서 하이브리드 환기시스템의 적용성을 검토하고, 하이브리드 환기시스템의 성능을 향상하기 위해 CFD시뮬레이션을 이용하여 설계방안을 제시하고자 하였다. 연구대상으로는 전용 $51m^2$, $84m^2$의 공동주택을 선정하였으며, 하이브리드 환기시스템은 창틀자연급기와 각실을 덕트로 연결하여 배기하는 시스템(Hybrid 1)과 창틀자연급기와 욕실 거실배기가 혼합된 시스템(Hybrid 2)을 적용하였다. 이때 각 시스템별 배기구의 위치를 변수로 하여 CFD를 수행하였다. $51m^2$, $84m^2$ 모두 Hybrid 2가 Hybrid 1보다 환기효율이 우수한 것으로 나타났으며, 평균공기연령 또한 낮은 것으로 나타났다. Hybrid 1의 경우, 덕트 배기구의 위치가 각 실 입구에 설치하는 것보다 실 안쪽 모서리에 설치하여 기류이동을 많이 유발할 수 있는 유형이 효과적인 것으로 나타났다. Hybrid 2의 경우, 욕실 고정압팬에 덕트를 연결하여 거실중심에 배기구를 설치하는 시스템이 환기효율이 가장 우수한 것으로 나타났다. 그러나 $51m^2$의 경우 Hybrid 2가 Hybrid 1보다 20%의 향상된 환기효율을 나타낸 반면, $84m^2$의 경우는 14%의 향상된 환기효율을 나타내 공동주택 규모에 따른 적정한 하이브리드 환기시스템에 대한 검토가 필요하다.

이중외피 시스템의 에너지성능평가를 위한 하절기 열환경 및 자연환기 분석 (Analysis of the Thermal Environment and Natural Ventilation for the Energy Performance Evaluation of the Double Skin System during the Summer)

  • 엄정원;조수;허정호
    • 한국태양에너지학회 논문집
    • /
    • 제22권4호
    • /
    • pp.68-76
    • /
    • 2002
  • This paper discusses thermal and ventilation performance which might be caused by the adoption of one of specific building facade techniques, Double Skin System(DSS). One building with a prototypical DSS was selected and systematically investigated through field monitoring and computer simulation techniques. A network model of ventilation was successfully made using COMIS to evaluate ventilation performance of the system which can hardly be done by field measurements. Various operating conditions of air conditioning on/off and window opening were implemented in this type of building. Through the appropriate operation of the DSS in summer, simulation-based and experimental results implicate that it can lead to cooling energy savings.

공동주택의 환기시스템별 에너지성능 비교 분석 (A Comparative Analysis of Energy Performance according to the Ventilation System in Apartment House)

  • 김길태;전주영;김선동
    • 토지주택연구
    • /
    • 제6권4호
    • /
    • pp.215-220
    • /
    • 2015
  • 본 연구는 공동주택에 적용되고 있는 환기장치를 선정하고 환기장치의 에너지특성 분석과 에너지저감을 목적으로 시뮬레이션 프로그램 (ECO2)을 이용하여 환기장치 별 에너지성능평가를 수행하였으며, 아래와 같이 결과를 도출하였다. 공동주택을 대상으로 환기장치 별 에너지 효율등급평가 기준에 따른 소비량을 수행하고자 하였다. 또한 단지별 에너지소비량과 비교 검토 결과를 통하여 현재 우리나라에서 공동주택에 적용하고 있는 환기장치별 에너지 소비량 실태를 파악하였다. 중부지방의 84type, 한 개동을 대상으로 시뮬레이션한 결과, 자연환기장치의 등급용 1차에너지소요량 값은 $159.9kWh/m^2yr$, 전열교환환기장치 $161kWh/m^2yr$, 바닥환기장치 $179.7kWh/m^2yr$로 계산 되었다. 위 시뮬레이션 결과를 공동주택의 실제 현장자료로 검증하였으며, 환기장치별 에너지소요량에 대한 비율로 비교해본 결과, 전열교환환기방식이 자연환기방식에 비해 -1~6% 적은 값을 보였으며, 바닥배관환기방식이 자연환기방식에 비해 약 10~20% 더 많은 1차에너지소요량이 나타났다. 환기장치의 팬동력과 열회수효율에 따라 에너지소요량의 난방과 환기 값이 변화하며, 향후 기계환기장치의 효율화 및 최적화가 필요하다고 판단된다.

후면 환기조건에 따른 건물외피용 태양광발전(BIPV) 모듈의 열적 영향에 관한 실험연구 (Experimental Study on the Thermal Effect of BIPV Modules Depending on the Ventilation Type of PV Module Backside)

  • 윤종호;김재웅
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.81-89
    • /
    • 2006
  • Building integrated photovoltaic (BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. On the other hands lots of architectural considerations should be reflected such as Installation position, shading, temperature effect and so on. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated This study is on the combined thermal and PV performance evaluation of BIPV modules. The purpose of this study is to investigate a temperature effect of PV module depending on the ventilation type of PV module backside. Test cell experiment was performed to identify the thermal and power effect of PV modules. Measurement results on the correlation of temperature and power generation were obtained. Those results can be utilized for the development of optimal BIPV installation details in the very early design stage.

주택 지붕일체형 PV시스템 후면환기에 따른 발전성능 변화 실험연구 (Experimental Study on the Combined Effect of Power and Heat according to the Ventilation of Back Side in Roof Integrated PV System)

  • 윤종호;한규복;안영섭
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.169-174
    • /
    • 2007
  • Building integrated photovoltaic(BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated. This study is to establish basic Information for designing effective BIPV by discovering relations between temperature and generation capability through experiment when the PV module is used as roof material for houses. To do so, we established 3kW full scale mock-up model with real size house and attached an PV array by cutting in half. This is to assess temperature influence depending on whether there is a ventilation on the rear side of PV module or not.

중복도형 인텔리전트빌딩 화재시 연기제어를 통한 피난안전성 확보에 관한 연구 (A Study on Securing Safety of Evacuation through Smoke Control in Case of Fire at the Central Corridor Type Intelligent Buildings)

  • 민세홍;이재문;배연준
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.117-127
    • /
    • 2015
  • This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.

권취식 창개폐시스템의 소요토크모델 개발 (Development of Theoretical Formulae for Calculation of Required Torque in Roll-up Type Ventilation System)

  • 박규식;이기명;정석현
    • 생물환경조절학회지
    • /
    • 제6권3호
    • /
    • pp.133-142
    • /
    • 1997
  • 본 연구는 권취식 창개폐기의 설계 및 개발에 필요한 자료를 제시하고자 수행되었다. 기존의 단순 이론모델식으로는 정확한 권취토크를 예측할 수 없기 전문에 모형시험과 현장시험을 통하여 새로운 권취식 창개폐장치의 소요토크 모델식을 개발하였다. 본 연구에서의 결과를 요약하면 다음과 같다. 1. 권취식 창개폐장치에 있어서 권취토크는 곡부 권취면의 경사각을 따라 증가하는 경향을 나타내고 있으며, 경사각이 90$^{\circ}$인 수직면에서 최대를 나타냈고 수편면에서 최소값을 나타냈다. 2. 온실의 길이에 따른 소요토크는 권취하중의 증가와 축파이프의 변형의 영향으로 지수함수적으로 늘어나는 경향을 나타냈다. 3. 권취식 창개폐장치의 소요토크 계산의 이론식은 T = W.(r+a).sin$\theta$+W.Cr.cos$\theta$로 나타낼 수 있으며, 여기서 축파이프의 권취반경 r과 축변형보정계수 $\alpha$를 더한 (r+$\alpha$)는 축파이프의 최대변형값인 $\delta$에 지수함수적으로 비례하는 경향이 나타났다. 4. 권취반경 r과 축변형보정계수 $\alpha$의 합인 (r+$\alpha$)은 22.2mm 파이프에 0.1mm 비닐로 피복을 했을 때 (r+$\alpha$)=2.10338$\times$$10^{0.00779{\delta}}$ 로 구할 수 있으며, 25.4mm 파이프에서는 (r+a)=2.58063$\times$$10^{(0.00452{\delta})}$로 구할 수 있다. 5. 권취식 창개폐장치의 소요토크에서 천창 등 곡부의 개폐시 고려되어야 할 굴름저항 보정계수는 피복재의 상태에 따라 다소 다를 수 있으나 0.7~0.8 정도의 값을 적용시키면 될 것으로 판단되었다. 6. 실제 권취식 창개폐를 사용하는 온실에서 권취축 파이프의 허용 변형정도를 최대 40cm 이하로 하는 것이 타당할 것으로 판단되며, 이때의 예상소요토크는 110m 온실인 경우 25.4mm 파이프를 축파이프로 사용한 경우 344kg.cm이며, 22.2mm 파이프의 경우 287kg.cm 정도이므로 새롭게 개발된 차동링기어 유성치 차감속기도 적당할 것으로 판단된다.

  • PDF

학교 교실의 태양광발전 환기시스템 적용성 연구 (A Study on Application of a Heat Recovery Ventilator using Photovoltaic System in School)

  • 장용성;서승직;홍성희;유권종;박효순
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.27-34
    • /
    • 2005
  • This study aims to evaluate application of a heat recovery ventilator(HRV) using photovoltaic(PV) system. To this end, we analyzed performance of a PV system, which it was evaluated by monthly power wattage and conversion efficiency according to design capacity of a HRV. The results of this study can be summarized as follows. (1) A conversion efficiency of the PCS was evaluated about 86% in rated power. (2) A maximum, minimum and average output power were respectively analyzed 49.2W, 47.3W, and 48.8W. (3) Total power wattage of 200W PV system was 211kW and it was 316kW in case of 300W PV system. (4) Insufficient electrical power of a duct and window type ventilation system was respectively calculated 133.5kW and 147.7kW.

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.