• Title/Summary/Keyword: Window Model

Search Result 813, Processing Time 0.034 seconds

Prediction of Heating Energy Saving Rate on the Window Type-Focus on the Apartment House (창호 구성 요소에 따른 난방에너지 절감율 예측에 관한 연구-공동주택을 중심으로)

  • Kim, Kyung-Ah;Moon, Hyeun-Jun;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.54-61
    • /
    • 2013
  • This is study on the glazing performance of the apartment house to predict energy saving rate when the early design stage by calculating heating load. there are various factors of the window type in apartment building to save energy such as window's U-value, SC or SHGC, window wall ration, frame factor, sunshade coefficient and so on. In this study, we analyzed the heating load focused on the U-value, SC and window wall ration using variable heating degree days method for a small and middle size units $59m^2$, $84m^2$, respectively. Each cases were calculated heating load of the real models compared to standard model to predict energy saving rate. From those cases it was drew the conclusion that were window's U-value, SC and window wall ration for the small and middle size units to expect 10% energy saving rate at least.

CAE Analysis on Strength and Fatigue of Rear Door of Passenger Car (승용차량 리어도어의 강도 및 피로에 대한 CAE해석)

  • Ko, Jong Hyoun;Kang, Dae Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.3
    • /
    • pp.63-69
    • /
    • 2014
  • This paper studies the strength, fatigue sensitivity, safety factor and lifetimes by means of structural and fatigue analyses of different models of rear doors upon the opening of doors and windows leading to severe fatigue fractures of the window motor components of rear doors. The simulation models were a standard model and other models. The other models, which are denoted here as models I and II, were modified versions of the standard model, with a rib of 3mm and a thickness of 2mm as compared to the standard model. The door was modelled with CATIA V5 and analyzed with the ANSYS program. The material of the rear door was cold rolled steel (DDQ). From the study results, the standard model and model I were confirmed to be less safe upon the opening of the door as compared to the opening of a window in terms of fatigue, but model II was found to be safe for both door and window openings.

Development of Optimum Design Technique for Bus Window Pillar Member (버스 윈도우 필라 부재의 형상 최적 설계기술 개발)

  • 김명한;김대성;임석현;서명원;배동호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.6
    • /
    • pp.156-164
    • /
    • 1999
  • The body structure of a bus is generally assembled by using various spot welded box sectional members. The shape of window pillar joint is ordinarily built up by T-type member. It has been shown that T-type member has problems like high stress concentrations, low fatigue strength and low structural rigidity. In this study, to solve these problems a new approach to optimize the design of the bus window pillar joint was tried by FEM analysis and experiments. To describe the shape of the gusset connecting the vertical and horizontal members of the T-type window pillar joint B-spline curve was adopted and this curve was optimized . It was found that the new model developed could effectively improve fatigue durability an structural rigidity.

  • PDF

A Study on the FIR Digital Filter using Modified Window Function (변형된 창함수를 사용한 FIR 디지털 필터에 관한 연구)

  • 강경덕;배상범;김남호;류지구
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.1
    • /
    • pp.49-55
    • /
    • 2003
  • The use of digital filters in the signal process field is increasing rapidly with development of the modern industrial society. Especially, detail processors, Y/C separators, ghost removing filters, standard converters (NTSC to PAL or PAL to NTSC) and noise reducers, all of which use digital filters, tend to be used in digital video and audio processing, CATV and various communication fields. Generally, there are two different digital filters, the Rf (infinite impulse response) filter and the FIR (finite impulse response) filter in digital filter. In this paper, we have designed FIR filter which has the phase linearity and the easiness of creation. In the design of the FIR digital filter, the window function is used to alleviate the ripples caused by Gibbs Phenomenon around the cut off frequency of the band pass. But there're some problems to choose proper window function for the design destination due to its fixed values. Therefore, in this paper, we designed a modified Hanning window with new parameter which is adaptively chosen corresponding to design objectives. The digital filter was simulated to prove the validity of the model and it was compared with the Hamming, the Manning, the Blacknan and the Kaiser window function. And we have used peak side-lobe and transient characteristics as standard of judgement.

  • PDF

A NONPARAMETRIC CHANGE-POINT ESTIMATOR USING WINDOW IN MEAN CHANGE MODEL

  • Kim, Jae-Hee;Jang, Hee-Yoon
    • Journal of applied mathematics & informatics
    • /
    • v.7 no.2
    • /
    • pp.653-664
    • /
    • 2000
  • The problem of inference about the unknown change-point with a change in mean is considered. We suggest a nonparametric change-point estimator using window and prove its consistency when the errors are from the distribution with the mean zero and the common variance. a comparison study is done by simulation on the mean, the variance, and the proportion of matching the true change-points.

Daylighting Performance of a New-Developed Energy Efficient Double-Skin Window System (에너지절약형 이중외피 창호의 기본채광 성능)

  • Park, Jong-Myung;Kim, Jae-Hoon;Choi, Jin-Woo;Lim, Hong-Soo;Kim, Gon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.117-122
    • /
    • 2008
  • The apartment will be much more convenient than the other one in the application of green technologies, providing the merits by mass production. For example, pre-manufactured building materials can be effectively adapted to the formation of buildings. Recently, the form of double-enveloped window system has been developed for the purposed of minimizing energy loss occurred around windows. On the other hand, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. A various types of glass can be applied to the window system and it plays a critical role in the determination of inner visual environment. For the purpose of verifying the potential of its daylighting, a mock-up model has been constructed and tested. The refurbished version of conventional window shows its illuminated characteristics. Clear and Low-e glass have been adapted for window area and daylighting ratio has been compared in both test cells.

  • PDF

Visual Comfort Evaluation of Interior Spaces by Daylighting Systems (채광시스템 유형별 실내공간의 시각적 쾌적성에 관한 평가)

  • Jeong, In Young;Choi, Yoon Seck;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • Daylight is a critical factor in architecture, as it enhances the working efficiency and visual comfort of the people working inside. Even though, low transmittance glazing has been used in the most office buildings in Korea. And it is reduced visual comfort in a indoor environment. So, we need to evaluation of quality for various daylighting systems to improve visual comfort This study aims to evaluate the visual comfort in a indoor environment by different daylighting system. For the purpose, four different daylighting systems-conventional window, conventional window with interior lightshelf, differentiated window, differentiated window with interior lightshelf-were selected and a questionnaire survey with 50 subjects were conducted. The results are as follows. Regardless daylighting systems, a view has an effect on visual comfort. A conventional system and conventional system with lightshelf were highly correlated between comfort and warmth. In case of differentiated window system were correlated between comfort and openness. Also, differentiated window with interior lightshelf were highly correlated between comfort and stability.

A Study on the Evaluation of the Daylighting Performance in the Sound Barrier Tunnel (축소모형을 이용한 방음터널의 자연채광 성능평가에 관한 연구)

  • Kim, Oim-Gon;Choi, Jeong-Min;Park, Chang-Seob;Lee, Kyung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.35-43
    • /
    • 2005
  • This study aims to evaluate the natural lighting performance in the sound barrier tunnel. Therefore, to evaluate the daylighting performance, the combinations of 3 tunnel roof types which are flat-roof-type(type A), slope-roof-type(type B), arch-roof-type(type C) and 3 window types which are side-window-type(type 1), one-window-roof type(type 2), two-window-roof type(type 3) are evaluated by experimenting small scaled models. In this 9 cases of experiment, illuminance levels of each case are analyzed and evaluated. The conclusion of this study is that slope-roof-type(B) and arch-roof-type(C) is preferable to flat-roof-type(A) and one-window-roof-type(B) and two-window-roof-type(C) is preferable to side-window-type(A) for daylighting in the sound barrier tunnel.

Improvement of the PVC Window Frame Installation Method Integrated with Gangform and Field Applicability Analysis

  • Choi, Hyo-Sung;Lee, Jeong-Ho;Yoo, Huyn-Seok;Kim, Young-Suk;Han, Seung-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.5
    • /
    • pp.482-500
    • /
    • 2011
  • In apartment housing construction, window frame installation work, which is conducted after the structural framework, is very important, because its completion time directly affects the starting time of successive interior finishing works, as well as the overall construction period. Construction delays in interior finishing works might occur due to problems inherent to the conventional window frame installation method, such as the poor verticality of window frames, and the water leakage around them. The primary objective of this study is to analyze the problems of a 'Gangform integrated PVC window frame pre-installation method' based on its pilot test results. Next, this study proposes an improved conceptual model that enables the end users to enhance the field applicability of this method in terms of productivity, time, and cost. The field applicability of the proposed 'Gangform integrated PVC window frame pre-installation method' was also verified through a survey.

A Study on Daylight Control Method for Securing Visual Comfort and Reducing Lighting Loads on Interior Lighting Environment (실내조명환경의 시각적 쾌적성 확보 및 조명부하 저감을 위한 채광제어방법에 관한 연구)

  • Han, Sang-Pil
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.100-105
    • /
    • 2012
  • In previous study, to investigate the impression of the compound lighting based on the AC-Model at the full-size room, the impressions of various compound lighting were completed as compared with that of the uniform lightings through the comparison method (a paired comparison) by Semantic Differential scaling. Also, we examined the effect of the supplementary lighting type increasing the lights at the side of the window and the blind-control lighting type, and they were compared with the existing compound lighting type. In results, pared comparison of the compound lighting and the uniform lighting, indicates that the impression of the compound lighting is generally similar to that of the uniform lighting when there are same ratios of the light from the window. Based on these results, we suggest that the AC-Model might be applied to various conditions. And we also introduce the method for daylighting that it is possible to reduce discomfort glare and to improve visual impressions as the supplementary type and blind-control type on the compound lighting. And it was found that electric power consumption of the compound lighting room was lower than that of the uniform lighting room when as same lighting ratio of the compound lighting and the uniform lighting from the window was provided or there was the lighting distribution simulated to same light ratio from the window. Since the method of the ACModel was described in the experimental condition, additional studies should be performed to determine if this model could be applied to different window configurations, lighting layout and types of a room.