Browse > Article
http://dx.doi.org/10.7836/kses.2012.32.6.100

A Study on Daylight Control Method for Securing Visual Comfort and Reducing Lighting Loads on Interior Lighting Environment  

Han, Sang-Pil (Dept. of Fire Protection and Safety, Sangji Youngseo College)
Publication Information
Journal of the Korean Solar Energy Society / v.32, no.6, 2012 , pp. 100-105 More about this Journal
Abstract
In previous study, to investigate the impression of the compound lighting based on the AC-Model at the full-size room, the impressions of various compound lighting were completed as compared with that of the uniform lightings through the comparison method (a paired comparison) by Semantic Differential scaling. Also, we examined the effect of the supplementary lighting type increasing the lights at the side of the window and the blind-control lighting type, and they were compared with the existing compound lighting type. In results, pared comparison of the compound lighting and the uniform lighting, indicates that the impression of the compound lighting is generally similar to that of the uniform lighting when there are same ratios of the light from the window. Based on these results, we suggest that the AC-Model might be applied to various conditions. And we also introduce the method for daylighting that it is possible to reduce discomfort glare and to improve visual impressions as the supplementary type and blind-control type on the compound lighting. And it was found that electric power consumption of the compound lighting room was lower than that of the uniform lighting room when as same lighting ratio of the compound lighting and the uniform lighting from the window was provided or there was the lighting distribution simulated to same light ratio from the window. Since the method of the ACModel was described in the experimental condition, additional studies should be performed to determine if this model could be applied to different window configurations, lighting layout and types of a room.
Keywords
Visual comfort; Visual comparison method; Compound lighting; Uniform lighting;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Han.S.P., A Study on Lighting Control Method for Harmonization of Daylighting and Artificial Lighting, Journal of Architectural Institute of Korea.,Vol.26, No.8, 2010   과학기술학회마을
2 Han.S.P.,The Effect of Compound Ratio for Daylighting and Artificial Lighting in Visual Impression, Journal of Architectural Institute of Korea., Vol.26, No.12, 2010.   과학기술학회마을
3 Han.S.P., Jeon.Y.H., Han.S.C., A Study on Visual Comfort for Compound lighting Control Method of Applied Daylighting, Journalof the Korea Solar Energy Society, Vol.32, No.3, 2012   과학기술학회마을   DOI
4 Toshie Iwata., AkiHtao., Masanori Shukuya., kenichi Kimura., Visual Comfort in the Daylit luminous environment, Lightingsres.Technol. 26(2),1994
5 Sato.M., Inui.M., Nakamura.Y., Takeuchi.Y., Visual environment of a controlroom, Lighting Res.Technol. Vol.21, No.3, 1989