• Title/Summary/Keyword: Window Glazing

Search Result 72, Processing Time 0.023 seconds

Daylighting Performance of Refurbished Window System based on Site Plans in Recently-Planned Apartment Houses (공동주택의 배치유형에 따른 창호 시스템의 채광특성)

  • Kim, Gon;Roh, Ji-Woong
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.37-44
    • /
    • 2008
  • Though they have advantages in terms of aesthetic in modern architecture, however, rectangular-shaped towers causes being short of natural light due to deep interior space. There are compromised attempts to take advantages of each building shape selectively. As a result, we now witness the advent of Y-shaped, T-shaped, V-shaped and ㅈ-shaped buildings on the market. The mutative type of apartment houses usually faces southwest or southeast, which has lot of daylighting availability but anyhow, the proportion of the apartment houses which have a full south aspect. The need to verify the potential of daylighting in new building-block shapes exists. At the same time, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. Recently, the refurbished version of conventional windows has been developed for the purposed of minimizing energy loss occurred around windows. This research initialized a series of research to deal with almost all on window wall for apartment houses. First of all, huge amount of already-designed examples of apartment houses have been analyzed in terms of floor plan, elevation, orientation and glazing materials.

Comparative Performance Evaluation of Advanced Daylighting Glazing Systems by Scale Model Measurements (축소모형을 이용한 가변 유리투과체의 채광유형별 성능평가 비교)

  • Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • The conventional way to acquire sufficient amount of daylight in interiors is to provide large openings with clear glass. The use of clear glass on the whole facade, however, might cause a sort of visual problem because of the harness of direct sun and brighter sky surface than expected. They should be filtered in opticalway or bounced in the architectural. One of the common solutions for the problem might be the use of photometric glasses with various transmittances for the glass walls. This paper deals with performance data related to the impact of various transmittal glazing materials for window systems in terms of daylighting. A series of scale model measurements was carried out with the fundamental configuration of a commonly used all-glass facades. Additionally some experimental performance index was issued for the better expression of the need of natural lighting.

A Study on the Evaluation of Thermal Transmittance Performance of Aluminum Alloy Window Frame of Educational Facility considering 2 Dimensional Steady-state Heat Transfer (2차원 정상상태 전열해석을 통한 교육시설의 알루미늄 창호 열관류율 평가에 관한 연구)

  • Park, Tong-So
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5284-5289
    • /
    • 2011
  • This study focused to evaluate thermal transmittance(U-value) performance of sliding type of aluminum alloy window frame(AAWF) with double glazing(DG) and glazing spacer and that without thermal breaker in winter and summer season by two dimensional steady state heat transfer analysis. The AAWE was installed to an existing educational facilities in Seosan area which is the southern region of the Korean Peninsula. Analysis of 2D steady-state heat transfer was performed through the use of BISCO as calculation and simulation program. U-value and temperature factors were calculated. The results are as followed. First, the isotherm simulation shows that AAWF with double glazing have serious differences from recently proposed window thermal performance standards such as Insulation Performance of Windows and Doors of Building Energy Saving Design Standards and the results of calculation of thermal transmittance performance of AAWF and DG are U=9.631 W/$m^2K$, U=2.382 W/$m^2K$ respectively during winter and summer season. Second, the results of analysis of heat transfer analysis, calculated by simulation, shows that 225% of heat is lost comparing with thermal performance standards U=4.0 W/$m^2K$ of general double glazing among those standards on AAWF without thermal breaker.

A Study of the evaluation of Building Energy Rating depending on region according to the Insulation Performance of the Super window (슈퍼윈도우 열성능에 따른 지역별 건물에너지 효율등급에 관한 연구)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.211-215
    • /
    • 2009
  • As entering in the time of high oil price, seriousness of an energy is on the rise and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy is expected to be possible to reduce energy demand more than other section. To reduce the building energy consumption, this study analyzes function and thermal performance of Super window by heat experimental apparatus. Super window is a 2-track low-e glazing window for high insulation efficiency. By applying the results of this experiment to building energy efficiency rating tool, this study compares energy efficiency rates depending on a region.-Jeju, South, Central. And it shows how much does Super window reduce Building energy consumption.

  • PDF

Structural glass panels: An integrated system

  • Bidini, G.;Barelli, L.;Buratti, C.;Castori, G.;Belloni, E.;Merli, F.;Speranzini, E.
    • Smart Structures and Systems
    • /
    • v.30 no.3
    • /
    • pp.327-332
    • /
    • 2022
  • In building envelope, transparent components play an important role. The structural glazing systems are the weak element of the casing in terms of mechanical resistance, thermal and acoustic insulation. In the present work, new structural glass panels with granular aerogel in interspace were investigated from different points of view. In particular, the mechanical characterization was carried out in order to assess the resistance to bending of the single glazing pane. To this end, a special instrument system was built to define an alternative configuration of the coaxial double ring test, able to predict the fracture strength of glass large samples (400 × 400 mm) without overpressure. The thermal and lighting performance of an innovative double-glazing façade with granular aerogel was evaluated. An experimental campaign at pilot scale was developed: it is composed of two boxes of about 1.60 × 2 m2 and 2 m high together with an external weather station. The rooms, identical in terms of size, construction materials, and orientation, are equipped with a two-wing window in the south wall surface: the first one has a standard glazing solution (double glazing with air in interspace), the second room is equipped with the innovative double-glazing system with aerogel. The indoor mean air temperature and the surface temperature of the glass panes were monitored together with the illuminance data for the lighting characterization. Finally, a brief energy characterization of the performance of the material was carried out by means of dynamic simulation models when the proposed solution is applied to real case studies.

Design and Performance Evaluation of Hybrid Window Walls With Variable Transmittal Materials (투과시스템의 광학특성을 고려한 복합적 외벽채광부의 성능평가에 관한 연구)

  • Do, Jin-Seok;Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.11-18
    • /
    • 2004
  • Growing use of entire glass facades with metal frames are popularly witnessed in modern building practices and design competition as well. In spite of architectural aesthetics and view to outdoors, environmental issues still exist in that kind of buildings. One of the solutions for the problems might be the use of functional glasses such as a heat-resistant glass or various tinted glasses for the glass walls. This paper aims to provide performance data related to the impact of various transmittal materials of window systems on the light distribution. A series of computer simulation deals with the basic geometrical and optical design elements of a commonly used all-glass facades. Additionally an experimental configuration of the vertical window is proposed for better result of daylighting. A window system equipped with an inner-light shelf can improve the uniformity of natural light in a space by reducing the level of illumination near the window and redirecting light deeply into the space.

Study on Estimate of Thermal Resistance of PVC Frame Window Due to Material Composition (PVC 창호의 구성에 따른 단열성능 예측에 관한 연구)

  • Sung, Uk-Joo;Lee, Jin-Sung;Cho, Soo;Jang, Cheol-Yong;Paek, Sang-Hun;Song, Kyoo-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1075-1080
    • /
    • 2006
  • Purpose of this study is proposal of estimating method about window thermal performance that based on KS F 2278 'Test method of thermal resistance for windows and doors' due to material composition of PVC frame window. First step of this study is research of present state about material composition of PVC frame window. Second is selection of main effective elements about window thermal resistance. For example, composition of Glazing, Frame area ratio of total window area, frame width, opening type, area of heat transfer and so on. Third is multiple regression analysis about thermal performance of PVC frame window due to main effective elements. It produces equations of multiple regression analysis due to opening type. Case of sliding window is $Y=0.149+0.034X_g+0.248X_{far}$, 4track sliding is $Y=0.584+0.175X_g+1.355X_{far}-0.008X_{fw}$, Tilt & Turn window is $Y=-0.161+0.076X_g+0.576X_{far}+0.0008X_{fw}$.

  • PDF

An Effective Algorithm for Transmitted Solar Radiation Calculation through Window Glazing on a Clear Day

  • Oh, John Kie-Whan
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.35-45
    • /
    • 2014
  • The main objective of this study is to provide an effective algorithm of the transmitted solar radiation calculation through window glazing on a clear day. This algorithm would be used in developing a computer program for fenestration system analysis and shading device design. Various simulation methods have been evaluated to figure out the most accurate and effective procedure in estimation of transmitted solar radiation on a tilted surface on a clear day. Characteristics of simulated results of each step have been scrutinized by comparing them with measured results of the site as well as results from other simulation programs. Generally, the Duffie & Beckman's solar calculation method introducing the HDKR anisotropic model provided the most reliable simulation results. The DOE-2 program usually provided over-estimated simulation results. The estimation of extraterrestrial solar radiation and beam normal radiation were conducted pretty accurately. However, the solar radiation either on horizontal surface or on tilted surface involves complicated factors in estimation. Even though the estimation results were close to the real measured data during summer when solar intensity is getting higher, the estimation provided more error when solar intensities were getting weaker. The convex polygon clipping algorithm with homogeneous coordinates was fastest model in calculation of sunlight to shaded area ratio. It could not be applied because of its shape limitation.

Study on Estimate of Window Condensation performance Due to Temperature Depreciation Ratio (표면 온도 저하율에 따른 창호부 결로성능 예측에 관한 연구)

  • Sung, Uk-Joo;Cho, Soo;Jang, Cheul-Yong;Lee, Jin-Seong;Peak, Sang-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1255-1260
    • /
    • 2006
  • This present study analyzed temperature depreciation ratio of window inside surface by KS F 2295 'Procedure for determining fenestration product condensation resistance values'. it estimated window indoor surface condensation due to variable environmental condition. Performance of condensation resistance by using temperature depreciation ratio until applied Low-e and Ar glazing improved about 45% from 24 mm clear. Temperature depreciation ratio by KS F 2295 considers analytic index of window condensation due to variable boundary condition.

  • PDF