• Title/Summary/Keyword: Winding temperature

Search Result 259, Processing Time 0.023 seconds

Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application (배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발)

  • Park, Dong-Keun;Seok, Bok-Yeol;Ko, Tae-Kuk;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.

Design of 1 MVA Single Phase HTS Transformer with Pancake Windings Cooled by Natural Convection of Sub-cooled Liquid Nitrogen

  • Kim, Woo-Seok;Kim, Sung-Hoon;Hahn, Song-yop;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Lee, Don-Kun;Park, Yeon-Suk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.34-37
    • /
    • 2003
  • A 1 MVA single-phase high temperature superconducting (HTS) transformer with BSCCO-2223 wire was designed in this paper. The rated voltages of each sides of the transformer are 22.9 kV and 6.6 kV respectively. Double pancake HTS windings arranged reciprocally will be used for the transformer windings, because of the advantages of insulation and distribution of surge voltage in case of a large power and high voltage transformer. Single HTS wire was used for the primary windings and four parallel wires were used for the secondary windings of the transformer with transposition. A core of the transformer was designed as a shell type core separated with the windings by a cryostat made of GFRP with a room temperature bore. The operating temperature of the HTS windings will be about 65K with sub-cooled liquid nitrogen. A cryogenic cooling system using a GM-cryocooler for this HTS transformer by natural convection of liquid nitrogen was designed. This type of cooling system can be a good option for compactness, efficiency, and reliability of the HTS transformer.

Capacitive Sensor for in situ Measurement of Deterioration of Car Engine Oil (자동차 엔진오일 열화상태 in situ 측정용 전기용량 센서)

  • Lee, R.D.;Kim, H.J.;Semenov, Yu. P.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.266-272
    • /
    • 2001
  • A coil-type capacitive sensor on which the deterioration of the car engine oil can be in situ measured, has been developed. The sensor was designed to get over 10 pF at the limited space on the drain hole of the oil pan. The design factors for stable capacitance measurement such as coil diameter and winding condition, materials and configuration of the coil former, and shielding method, etc., were known by both computer simulation and experimental investigations. The dielectric properties measured by several sensors for an used sample oil were consisted within 0.25%. The sensor installed on the car having severe vibration, temperature and humidity fluctuation, even electromagnetic noise, has shown very distinguishable results.

  • PDF

Measurement Method of Residual Stresses in Thick Composite Cylinders (두꺼운 복합재 원통의 잔류응력 측정방법)

  • Kim, Jong-Woon;Park, Dong-Chang;Lee, Dai-Gil
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.245-248
    • /
    • 2005
  • During manufacturing thick composite cylinders, large thermal residual stresses are developed and induce catastrophic interlaminar failures. Since the residual stresses are dependent on many process parameters, such as temperature distribution during cure, cure shrinkage, winding tension, and migration of fibers, calculation of the residual stresses is very difficult. Therefore a radial-cut method have been used to measure the residual stresses in the composite cylinders. But the conventional radial-cut method needs to know numerous material properties which are not only troublesome to obtain but also vary with change of fiber arrangement during consolidation. In this paper, a new radial-cut method with cut-cylinder-bending test was proposed and the measured residual stresses were compared with calculated thermal residual stresses. It was found that the new radial-cut method which does not need to know any of material properties gave better estimation of residual stresses regardless of radial variation of material properties. Additionally, interlaminar tensile strength could be obtained by the cut-cylinder-bending test.

  • PDF

Application of Acoustic Emission Technique for On-Line Monitoring of Quench in Racetrack Superconducting Coil at Cryogenic Environment (음향방출기법을 이용한 극저온 환경하에서 초전도 계자코일의 퀀칭탐지 적용에 관한 연구)

  • Lee, Min-Rae;Gwon, Yeong-Gil;Lee, Jun-Hyeon;Son, Myeong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.858-865
    • /
    • 2000
  • It is well recently recognized that quench is one of the serious problems for the integrity of superconducting magnets, which is mainly attribute to the rapid temperature rising in the magnet due to some extrinsic factors such as conductor motion, crack initiation etc. In order to apply acoustic emission(AE)echnique effectively to monitor and diagnose superconducting magnets, it is essential to identify the sources of acoustic emission. In this paper, an acoustic emission technique has been used to monitor and diagnose quenching phenomenon in racetrack shaped superconducting magnets at cryogenic environment of 4.2K. For these purposes special attention was paid to detect AE signals associated with the quench of superconducting magnets. The characteristics of AE parameters have been analyzed by correlating with quench number, winding tension of superconducting coil and charge rate by transport current. In addition, the source location of quench in superconducting magnet was also discussed on the basis of correlation between magnet voltage and AE energy.

Development and rotating test of the high temperature superconducting motor with on-board cryocooler (탑재형 냉동기를 이용한 고온 초전도 모터 개발 및 회전 실험)

  • Ki, Tae-Kyung;Kim, Young-Kwon;Kim, Hee-Sun;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.12-16
    • /
    • 2011
  • In this paper, the prototype of the HTS motor with an on-board cryocooler, is fabricated and tested. The overall system is composed of the stator with conventional copper winding, the rotor with superconductor, and the rotating cryocooler designed from the on-board concept. The rotor is fabricated as the race-track coil with 2G, YBCO tape and contacts with the on-board cryocooler while being rotated together. An inline-type pulse tube refrigerator is used as the on-board cryocooler. The cryocooler is fabricated from optimal process to satisfy the structure and thermal stability of the on-board system. Each component is integrated according to carefully defined sequence. Specially, a combining method of torque tubes is an important part for sustaining stability of the rotor and the cryocooler. In the rotating test, the HTS motor is successfully operated with 240 rpm of rotating speed when 75 A current is supplied to the superconducting rotor. In this paper, potential problems of the HTS motor system using the on-board cryocooler are proposed and solved, and realistic possibility of this concept is also confirmed.

Velocity and temperature profiles of Al/water micro fluid in a circular tube with swirl

  • Chang, Tae-Hyun;Lee, Kwon Soo;Lee, Chang-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.7
    • /
    • pp.677-684
    • /
    • 2013
  • A lot study of convection heat transfer on internal flow has been extensively conducted in the past decades using of high specific surface area, increasing heat transfer coefficient, swirling flow and improving the transport properties. This study concerned with the application of a tangential slot swirl generator for improving heat transfer in a horizontal circular copper tube. The Al particles(about $100{\sim}130{\mu}m$) was employed for this experimental work. 3D PIV(particle image velocimetry) technique has employed to measure velocity profiles of Al particles with and without swirl flow. The copper tube is heated uniformly by winding of a heating coil for heat transfer work, having a resistance of 9 ohm per meter. Experiments are performed in the Reynolds number range of 6,800~12,100 with swirl and without swirl using Al particles. Experimental data for comparison of Nusselt number is presented that of with swirl and without swirl along the test tube for the Reynolds numbers. The Nusselt number is improved with increasing of Reynolds numbers or swirl intensities along the test tube. The Nusselt number with swirl flow is about 60.0% to 119.0% higher than that obtained by the Dittus-Boelter equation.

Design of a Switched Reluctance Motor Driving an Electric Compressor for HEVs (하이브리드 자동차(HEV) 용 전동식 컴프레서 구동을 위한 SRM 설계)

  • Jeong, Yong-Hoe;Jeon, Yong-Hee;Kang, Jun-Ho;Kim, Jaehyuck
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.620-625
    • /
    • 2013
  • This paper presents the design of a switched reluctance motor (SRM) for electric air conditioning compressors which are applied to hybrid electric vehicles (EVs). The motor for driving air conditioning compressor which is recently used on EV(electric vehicle) / HEV (hybrid electric vehicle) is PMSM(permanent magnet synchronous motor) or BLDCM(brushless DC motor). However disadvantage of motors that uses permanent magnets are vulnerable to high temperatures because of the demagnetization by the high temperature and the permanent magnet is expensive because of the high price of rare earth materials from China's monopoly. Therefore, in the automotive insustry is interested in the non-rare-earth motors. SRM has many advantages. it's resistant to high temperatures, price is cheaper, because there are no permanent magnets and winding in the rotor. Also it's high relability and efficiency, suitable for high-speed operation because of structure is simple. In this paper, the SRM, non-rare-earth motor, are designed, analyzed and experimented drive to replace an existing electric compressor drive motor.

An Experimental Study on the Convection Heat Transfer of Al-Mg/water Micro Fluid in a Circular Tube with Swirl

  • Chang, Tae-Hyun;Kim, Chiwon;Kil, Sang-Cheol;Lee, Chang-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.7
    • /
    • pp.869-875
    • /
    • 2012
  • In the past decades, extensive studies on convection heat transfer on internal flow have been conducted by using high specific surface area, by increasing heat transfer coefficient and swirl flow, and by improving the transport properties. In this study, we applied a tangential slot swirl generator to improve heat transfer in a horizontal circular copper tube. The Al-Mg particles (approximately $100{\mu}m$ to $130{\mu}m$) were employed for this experimental work. The copper tube was heated uniformly by winding a heating coil with a resistance of 9 ohm per meter for heat transfer. Using Al-Mg particles, experiments were performed in the Reynolds number range of 5,000 to 13,130, with and without swirl. Experimental data transfers or comparisons between Nusselt numbers with and without swirl along the test tube and Reynolds numbers are presented. The Nusselt number is improved by increasing Reynolds numbers or swirl intensities along the test tube.

An Experimental Study on the Convection heat Transfer of Al-Mg/water Micro Fluid in a Circular Tube with Swirl (선회유동장에서 Al-Mg/물 마이크로 유동의 대류 열전달에 대한 실험적 연구)

  • Chang, Tae-Hyun;Kim, Chi-Woon;Kil, Sang-Cheol;Lee, Chang-Hoan
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.3
    • /
    • pp.16-20
    • /
    • 2012
  • In the past decades, extensive studies on convection heat transfer on internal flow have been conducted by using high specific surface area, by increasing heat transfer coefficient and swirl flow, and by improving the transport properties. In this study, we applied a tangential slot swirl generator to improve heat transfer in a horizontal circular copper tube. The Al-Mg particles (approximately $100{\mu}m$ to $130{\mu}m$) were employed for this experimental work. The copper tube was heated uniformly by winding a heating coil with a resistance of 9ohm per meter for heat transfer. Using Al-Mg particles, experiments were performed in the Reynolds number range of 5,000 to 13,130, with and without swirl. Experimental data transfers or comparisons between Nusselt numbers with and without swirl along the test tube and Reynolds numbers are presented. The Nusselt number is improved by increasing Reynolds numbers or swirl intensities along the test tube.