• Title/Summary/Keyword: Winding temperature

Search Result 259, Processing Time 0.024 seconds

Analysis on the Operation Characteristics of Induction Motor Operated by Unbalanced Voltage (불평형 전압 운전시 유도전동기의 동작 특성 해석)

  • 김종겸;박영진;정종호;이은웅
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.6
    • /
    • pp.372-379
    • /
    • 2004
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Rotating machines operating on an unbalanced voltage will draw a highly unbalanced current. As a result, the three-phase currents may differ considerably, thus resulting in an increased temperature rise in the machine. This paper presents a scheme on steady states of a three-phase induction motor under unbalanced voltages. The three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting the magnitude and phase angle of each phase. The voltage unbalanced factor(VUF) of the three-phase source voltages can then be varied to examine the different values of VUF on machine's operation characteristics.

Development of the Controller for TFM with Contol-Rod (제어봉 구동장치용 횡자속형 전동기의 제어기 개발)

  • Kim J.M.;Jeong Y.H;Kang D.H.;Im T.Y.;Kim D.H.;Lee S.G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.284-287
    • /
    • 2001
  • In the System-integrated modular advanced reactor(SMART), the motor for Control element drive mechanism(CEDM) requires high density power and simple drive mechanism to reduce volume because of restriction by install-space and must satisfy the reactor operating circumstances with high pressure and temperature. To Maximize the characteristics of the TFM, we chose the asymmetric bridge converter as the driving system for TFM. Because two switching devices are connected in series with the stator winding of each phases in the asymmetric bridge converter all the phases are not affected by another phase but controlled independently. Also, this converter has many advantages that the various control methods can be adopted, it is easy to control, and that in case that the switching devices of a phase are damaged, the affects can be minimized.

  • PDF

Test and Characteristic Analysis of an HTS Power Transformer (고온초전도변압기의 특성해석 및 시험)

  • Lee, H.J.;Cha, G.S.;Lee, J.K.;Choi, K.D.;Ryu, K.W.;Hahn, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.321-323
    • /
    • 2000
  • This paper describes the construction and test results of a 10kVA single phase HTS transformer. Double pancake windings with BSCCO-2223 HTS tape and GFRP cryostat with room temperature bore are used in the transformer. Two double pancake windings are connected in series to provide 184 turns and two double pancake windings are connected in parallel to conduct the secondary current of 45.4A. Coefficients of the constructed transformer are obtained using the fundamental tests of the transformer. According to the test results, larger leakage reactance than expected is observed due to the bulky core which surrounded the cryostat.

  • PDF

Solution to Some Key Problems of Self-exciting Electronic Ballast

  • Mao, Peng;Zhang, Weiping;Zhang, Mao
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Self-exciting electronic ballast, of small size, and low cost, and high power, with no stroboscopic effect, no noise, is widely used in the general lighting market. This paper describes the cause of high switching loss of self-exciting electronic ballast, based on its operational principle; then, to reduce the switch temperature and increase the reliability of the product, the drive circuit has been improved, to achieve soft-switching. The theory analysis, simulation and experimental result prove the feasibility and compatibility of this new method in practice. Finally, the design procedure and winding method of the self-exciting current transformer are introduced.

A Study on Thermal, Mechanical and Electrical Properties as Silane Treated Epoxy/MICA Composites (실란처리된 Epoxy/MICA 콤포지트의 열적, 기계적 전기적 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.213-218
    • /
    • 2013
  • In this study, epoxy/mica composite was prepared by mixing with mechanical stirrer together with homogenizer, and the effect of amino-type silane coupling agent was also studied. To reduce the viscosity without any decrement of other properties, 1,4-Butanediol diglycidyl ether (1,4-BDGE) as an aliphatic epoxy reactive diluent was introduced to the epoxy/mica composite in order to use as vanish for high voltage motor and generator stator winding. It was confirmed by scanning electron microscopy (SEM) observation that interfacial characteristics between organic epoxy and inorganic mica was modified by coupling agent treatment so that glass transition temperature increased, and tensile strength and electrical breakdown strength increased. The properties were estimated by Weibull statistical analysis and the ac electrical breakdown strength was 20.2% modified by treating silane coupling agent.

Development of Online Monitoring System for Induction Motors (유도전동기 온라인 감시진단 시스템 개발)

  • Kim, Ki-Bum;Youn, Young-Woo;Hwang, Don-Ha;Sun, Jong-Ho;Jung, Tea-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.23-30
    • /
    • 2014
  • This paper presents an on-line diagnosis system for identifying health and faulted conditions in squirrel-cage induction motors using stator current, temperature, and partial discharge signals. The proposed diagnosis system can diagnose induction motor faults such as broken rotor bars, air-gap eccentricities, stator winding insulations, and bearing faults. Experimental results obtained from induction motors show that the proposed system is capable of detecting induction motor faults.

Fault Prediction & Reliability Estimation of the Traction Motor by the Complex Accelerating Degradation and Condition Diagnosis (견인전동기의 복합가속열화 상태진단에 의한 고장예측 및 신뢰성 평가)

  • 왕종배;김명룡
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.763-766
    • /
    • 2000
  • In this paper, stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the 200 Class insulation system of traction motors. The complex accelerative degradation was performed by periods during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of 20∼160$^{\circ}C$. Relationship among condition diagnosis test was analyzed to find an dominative degradation factor and an insulation state at end-life point.

  • PDF

Effect of Epoxy Cracking on Initial Quench Behavior about High Field Superconducting Magnet

  • Lee, B.S.;Kim, D.L.;Choi, Y.S.;Yang, H.S.;Yoo, J.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.4
    • /
    • pp.26-29
    • /
    • 2006
  • The study to be presented related on initial behavior of quench concerned with many considerations, such as epoxy impregnated coil, critical current density related on strain and temperature, winding effect and behavior of internal superconducting wire. Especially, the deformation behavior of coils under magnetic field and thermal contractions at cryogenic temperatures to be dealt with the analytical method related on Fracture Mechanics. From the results, we know that the strain by self weight contribute to epoxy cracking at the edge of deformed coils and the deformation behavior relate on epoxy cracking must be dealt with biaxial loading problem. Then, the epoxy crack on $r\theta-plane$ under biaxial loading have been propagated with inclined crack angle and joined superconducting wire. Also, we can explain transfer of epoxy crack propagation energy from epoxy resin to superconducting wire.

Experimental study on the correlation between measurement length and winding or twist pitch for magnetization loss occurring in CORC and TSTC

  • Ji-Kwang Lee;Jinwoo Han;Kyeongdal Choi;Woo-Seok Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.40-44
    • /
    • 2023
  • For high-temperature superconducting power applications that need large current capacity, a large current conductor manufactured using multiple superconducting tape is required. Conductors being studied for large currents capacity such as CORC, TSTC, and RACC have advantages and disadvantages, and in order to use these conductors in coil form and apply them to AC power devices, research on magnetization loss occurring in superconductors due to external magnetic fields is essential. To accurately measure magnetization loss in a conductor that is twisted by stacking straight conductors like TSTC, the correlation between the measuring system and the shape of the sample must be clearly known to accurately measure the loss. In this paper, we will confirm the difference in magnetization loss measurement values according to the correlation between the length of the pickup coil and the twist pitch of the sample in CORC and TSTC shapes, and review considerations for accurate magnetization loss measurement from the results.

Determination of formaldehyde residue and histopathological observation in formalin and neutral-formalin treated Korean rockfish(Sebastes schlegeli) (포르말린과 중성포르말린 약욕한 어류의 Formaldehyde 잔존량 측정과 병리학적 관찰)

  • Cho, Jae-Kwon;Yang, Han-Choon
    • Journal of fish pathology
    • /
    • v.9 no.2
    • /
    • pp.157-168
    • /
    • 1996
  • In this study, Residue of formaldehyde and histopathological changes in formalin and neutralformalin in treated fish(Sebastes schlegeli) were observed at two different temperatures(15 and $25^{\circ}C$). Immediately after in treatment, residue of formaldehyde in formalin treated fish was show little bit higher than in neutral-formalin treated fish at $15^{\circ}C$. But, there is no difference at water temperature $25^{\circ}C$. The elimination of formaldehyde was markedly temperature-dependent. The approximated withdrawal time were 72hr and 24hr at water temperature 15 and $25^{\circ}C$. Formalin was more toxic than the neutral-formalin at the same condition. Intensity of tissues damage was increased with increasing concentration of chemical and temperature. Formalin and neutral-formalin treatments caused edema and seperation of epithelium, winding of secondary gill lamella, necrosis in the gill ; congestion and pycnosis, vacuolation in the liver ; hydropic and granulated degeneration, necrosis of epithelial cells in the proximal renal tubule ; increasing mucus cells, cracking, necrosis of epidermis and dermis in the skin tissue.

  • PDF