• 제목/요약/키워드: Winding coil

검색결과 269건 처리시간 0.025초

Current Limiting Characteristics of Flux-lock Type SFCL according to Inductance Variation

  • Choi Hyo-Sang;Park Hyoung-Min;Cho Yong-Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권2호
    • /
    • pp.87-89
    • /
    • 2006
  • We investigated the current limiting characteristics of flux-lock type superconducting fault current limiter(SFCL) according to inductance variation of coil 2. The flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil through an iron core, and the secondary coil is connected to the superconducting element in series. The operation of the flux-lock type SFCL can be divided into the subtractive and the additive polarity winding operations according to the winding directions between the coil 1 and coil 2. The current limiting characteristics in two winding directions were dependent of on the ratio of the number of turns of coil I and coil 2. The fault current increased when the number of turns of coil 2 increased in the subtractive polarity winding. On the contrary, the fault current decreased under the same conditions in case of the additive polarity winding.

자속구속형 전류제한기의 초기 사고전류 제한시점 변화 (Variance of Initial Fault Current Limiting Instant in Flux-lock Type SFCL)

  • 박충렬;임성훈;박형민;최효상;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권3호
    • /
    • pp.269-275
    • /
    • 2005
  • A flux lock-type SFCL consists of two coils which are wound in parallel each other through an iron core, and a HTSC thin film connects in series with coil 2. The operation of the flux-lock type SFCL can be divided into the subtractive polarity winding and the additive polarity winding operations according to the winding directions between coil 1, coil 2. When a fault occurs, the fault current in the HTS thin film exceeds the critical current so that resistance is generated in the HTS film, and thereby the fault current is limited by an instant rise in the impedance of the flux-lock type SFCL. We investigated he variances of initial fault current limiting instant according to the ratio of inductance of coil 1 and coil 2 in the flux-lock type SFCL. It was confirmed from experiments that the initial fault current limiting instant in the subtractive polarity and additive polarity windings were faster as the ratio of coil 2' inductance for coil 1's inductance increased. The 1st peak of fault current in case of the subtractive polarity winding was higher as the ratio of coil 2's inductance for coil 1's inductance increased. On the other hand, in case of the additive polarity winding, the 1st peak of fault current was lower.

Effect of Winding Coil Diameter on AC Insulation Breakdown Voltage of Polyamideimide/Nanosilica Wire

  • Park, Jae-Jun;Woo, Myung-Ha;Lee, Jae-Young;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권4호
    • /
    • pp.231-234
    • /
    • 2016
  • The AC insulation breakdown voltage was investigated for seven types of winding coils made of polyamideimide (PAI), flexural PAI (nanosilica 5 wt%) and anti-corona PAI (nanosilica 15 wt%) wires with various winding coil diameters of φ5, φ15 and φ25 mm. The winding coil was made of enameled wire with an enamel thickness of 30~50 μm, and the rectangular copper wire had a thickness of 0.77~ to 0.83 mm and width of 1.17~ to 1.23 mm, respectively. The insulation breakdown voltages of the original PAI coils with diameters of φ5, φ15 and φ25 mm were 7.30, 6.58, and 5.95 kV, respectively, and those values decreased as the winding coil diameter increased, regardless of the wire types.

개선된 자속구속형의 2차 측 권선 방향과 1차 권선수와 2차 권선수의 변화에 따른 사고전류제한 특성 (Current Limiting Characteristics of Improved Flux-Lock Type SFCL According to Winding Direction of Coil 2 and Variable Number of Coil 1 and Coil 2)

  • 김용진;두호익;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제23권9호
    • /
    • pp.714-717
    • /
    • 2010
  • The improved flux-lock type superconducting fault current limiter (SFCL) is composed of a series transformer and superconducting unit of the yttrium-barium-copper-oxide (YBCO) coated conductor. In this paper, we investigated current limiting characteristics through winding direction of coil 2 and variable number of coil 1 and coil 2 in improved flux-lock type SFCL. The better fault current characteristics and the burden of YBCO coated conductor can be confirmed from the experimental result in the higher turn ratio of coil 1 and coil 2 in the additive conditions. In case of subtractive condition, we can confirm a similar result in the same case of experimental conditions. but the burden of YBCO coated conductor has been increased from an increase in winding numbers of coil 2.

자속 구속형 전류제한기의 사고각에 따른 초기 사고전류 제한 시점 변화분석 (Variations of Initial Fault Current Limiting Instant According to Fault Angles in the Flux-lock Type SFCL)

  • 박충렬;임성훈;박형민;최효상;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.61-64
    • /
    • 2004
  • In this paper, we investigated the variations of initial fault current limiting instant according to fault angles in the flux-lock type SFCL. The flux-lock type SFCL consists of the coil 1 and the coil 2 that are wound in parallel each other through an iron core. The operation of the flux-lock type SFCL can be divided into the subtractive polarity winding and the additive polarity winding operations according to the winding directions between the coil 1 and coil 2. The subtractive polarity winding operation could be analyzed with three modes. On the other hand, the additive polarity winding operation could be analyzed with five modes. The variations of initial fault current limiting instant in two winding directions were dependent on the fault angles. It was confirmed from experiment that the fault current limiting instant was getting faster and the magnitude of fault current at the initial fault time was getting higher for higher fault angle.

  • PDF

모터 고정자 코일 권선기의 동특성 개선 연구 (A Study on the Improvement of Dynamic Characteristics of the Motor Stator Coil Winding Machine)

  • 김동성;김광영;함상용;손영수
    • 대한기계학회논문집A
    • /
    • 제27권9호
    • /
    • pp.1589-1596
    • /
    • 2003
  • In this paper, we performed the improvement study for the dynamic characteristics enhancement of the motor stator coil vertical winding machine. The dynamic characteristics improvement was done by means of the optimized design and the weight reduction of the flyer configuration, modified design of the servo control system for the flyer and the former actuation, and the development of jump timing digital circuit for the reduction of former jumping error. As the results, the maximum winding speed pattern of the developed machine was attained up to 3000rpm and also reduced the jumping error. In conclusion, domestic design technology for manufacturing the motor coil vertical winding machine was established through this study.

전동기 소손에 대한 화재 원인 분석에 관한 연구 (A Study on the Fire Cause Analysis of Motor Damage)

  • 이춘하;옥경재;권병덕
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.59-64
    • /
    • 2007
  • 본 논문은 전동기에 발생하는 화재에 대한 연구로서, 일반가전제품에 사용되고 있는 단상유도전동기에 과부하 및 외부화염을 가하여 그 변형 및 파손상태를 비교 분석하였다. 실험은 전동기의 구속을 통한 과부하 시험과 외부에서 화염을 가하는 실험으로 진행하였으며, 외부화염 시험의 경우 전압을 인가한 경우와 인가하지 않은 경우로 구분하였다. 실험결과 구속을 통한 과부하 시험의 경우 권선부분에서 층간 단락흔을 관찰할 수 있었고, 권선부분의 조직에서는 과부하에 의해 변형된 전선의 특징인 나무줄기 형상의 수지상 조직이 나타났다. 전압을 인가한 상태에서 외부화염을 가한 경우 고정자 권선부분의 코일이 원형을 유지하고 있는 것을 확인할 수 있었고, 권선주변의 색이 붉게 변색된 것을 볼 수 있었다. 전압을 인가하지 않고 외부화염을 가한 경우 고정자 권선부분의 코일이 원형에서 많이 변형된 것을 관찰할 수 있었고, 권선 주변의 색은 전압을 인가한 경우와 마찬가지로 붉게 변색된 것을 확인할 수 있었다.

0.7 MJ $\mu$SMES코일 제작을 위한 소형 초전도코일의 특성 (Characteristics of a Small SC Coil for fabrication of the 0.7 MJ $\mu$SMES Coil)

  • 류경우;김해종;성기철;류강식
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권1호
    • /
    • pp.13-18
    • /
    • 1999
  • To fabricate a 0.7 FJ, 100 kVA $\mu$SMES device for improving power quality in sensitive electric loads, we developed a design code for a $\mu$SMES device and designed the 0.7 MJ $\mu$SMES device by using it. In this study special emphasis was placed in influence of winding tensions on quench currents of superconducting coils because dry superconducting coils are usually quenched by local disturbances due to strand motions. We first investigated the quench currents of a few kA class superconducting cables for various winding tensions experimentally. To prove the validity of the code and develop all techniques related to fabrication and test of the 0.7 MJ $\mu$SMES device, a smaller size superconducting coil was wound with high winding tension of about 15 kgf/$mm^2$ based on the test results of superconducting cables and tested. It isshown form the test results that designed parameters for the smaller size superconducting coil are in good agreements with measured ones and the quench current of the coil with high winding tension reaches nearly to the critical current of the superconducting cable without any training effects.

  • PDF

유한요소해석을 이용한 다상의 초전도 코일에 대한 기계적 열적 등가 물성 (Equivalent Mechanical and Thermal Properties of Multiphase Superconducting Coil Using Finite Element Analysis)

  • 사정우;허남일;최창호;오영국;조승연;도철진;권면;이경수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.975-980
    • /
    • 2001
  • Like composite material. the coil winding pack of the KSTAR (Korea Superconducting Tokamak Advanced Research) consist of multiphase element such as metallic jacket material for protecting superconducting cable, vacuum pressurized imprepregnated (VPI) insulation, and corner roving filler. For jacket material, four CS (Central Solenoid) Coils, $5^{th}$ PF (Poloidal Field) Coil, and TF (Toroidal Field Coil) use Incoloy 908 and $6-7^{th}$ PF coil, Cold worked 316LN. In order to analyze the global behavior of large coil support structure with coil winding pack, it is required to replace the winding pack to monolithic matter with the equivalent mechanical properties, i.e. Young's moduli, shear moduli due to constraint of total nodes number and element numbers. In this study, Equivalent Young's moduli, shear moduli, Poisson's ratio, and thermal expansion coefficient were calculated for all coil winding pack using Finite Element Method.

  • PDF

삼상 분리형 자속커플링 전류제한기의 2차 권선의 턴 수 및 결선 방향에 따른 전류제한 특성 (Current Limiting Characteristics of Separated Three-phase Flux-coupling Type SFCL according to Winding Number of Coil 2 and Winding Direction)

  • 김용진;두호익;두승규;김민주;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제22권8호
    • /
    • pp.694-697
    • /
    • 2009
  • The separated three-phase flux-coupling type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In this paper, we investigated the current limiting characteristics through winding number of coil 2 and winding direction in the flux-coupling type SFCL. Through the analysis, it was shown that additive polarity condition and lower winding number of coil 2 have advantaged from the point of view of fault current limiting and burned of YBCO coated conductor.