• 제목/요약/키워드: Winding Resistance

검색결과 161건 처리시간 0.03초

Yarned CNT Fiber 저항체의 전기적 특성 (Electrical Properties of Yarned Carbon Nanotube Fiber Resistors)

  • 임영택;이선우
    • 한국전기전자재료학회논문지
    • /
    • 제30권1호
    • /
    • pp.59-62
    • /
    • 2017
  • CNT (carbon nanotube) resistors with low resistance and negative TCR (temperature coefficient of resistance) were fabricated with yarned CNT (carbon nanotube) fibers. The CNT fibers were prepared by yarning CNTs grown on the silicone substrate by CVD (chemical vapor deposition) method. The CNT resistors were fabricated by winding CNT fibers on the surface of ceramic rod. Both metal terminals were connected with the CNT fiber wound on the ceramic rod. We measured electrical resistance and thermal stability with the number of CNT fibers wound. The CNT resistor system shows linearly decreased resistance with the number of CNTs wound on the ceramic rod and saturated at 20 strands. The CNT resistor system has negative TCR between $-1,000{\sim}-2,000ppm/^{\circ}C$ and stable frequency properties under 100 kHz.

양측 여자형 다분할 LDM의 특성해석 (Characteristics Analysis of Double Side Excitation Type Multi-separated LDM)

  • 윤신용;백수현;김용
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.64-72
    • /
    • 2002
  • 산업의 발달에 따라 선형 직류 모터의 용용이 확대되고 있다. 본 연구에서는 가동차석형 양측식 다분할 여자 LDM의 해석을 연구대상으로 하였다. 본 LDM의 구조에서 가동자는 큰 추력을 얻도록 영구지석 6개를 사용하였으며, 고정자는 철심의 포화를 억제 하도록 다 분할형 권선을 성층하였다. 또한 양측 여자 권선은 지그재그형으로 성 층하여 추력의 리플을 억제하고, 정추력을 발생할 수 있도록 설계하였다. 여기에 다 분할시 영구자석대 권선 폭의 비가 중요하므로 본 연구에서는 똑비를 1 : 1, 1 : 0.84 및 1 : 0.5의 3개 부분으로 나누어 해석하였다. 해석 방법은 복잡한 수치해석의 유한요소법 보다는 퍼미언스 및 자기저항 법을 이용하여 파라며터를 계산하였다. 제작된 실험장 치를 통하여 추력을 측정한 결과는 전 변위에 대해서 정추력이 발생함을 알 수 있었다.

13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석 (Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings)

  • 장정호;이동근;이흥호
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

파라미터 보상기를 가지는 비대칭 SRM의 센서리스 속도제어 (A Sensorless Speed Control of 2-Phase Asymmetric SRM with Parameter Compensator)

  • 임근민;안진우;이동희
    • 전력전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.238-245
    • /
    • 2012
  • This paper presents a sensorless speed control of a 2-phase switch reluctance motor(SRM). The proposed sensorless control scheme is based on the slide mode observer with parameter compensator to improve the estimation performance. In the stand still position, the initial rotor position is determined by pulse current responses of each phase windings and the current difference. In order to determine an accurate initial rotor position, the two initial rotor positions are estimated by the difference of the pulse currents. From the stand still to the operating region, a simple open loop control which determines the commutation sequence by the pulse current of the unexcited phase winding is used. When the motor speed is reached to the sensorless control region, the estimated rotor position and speed by the slide mode observer are used to control the SRM. The flux calculator used in the slide mode observer is designed by phase voltage and the voltage drops in the phase resistance of the winding. The accuracy of the flux calculator is dependent on the phase resistance. For the continuous update of the phase resistance, current gradient at the inductance break point is used in this paper. The error of the estimated rotor position at the current gradient position is used to update the phase resistance to improve the sensorless scheme. The proposed sensorless speed control scheme is verified with a practical compressor used in home appliances. And the results show the effectiveness of the proposed control scheme.

3상 22.9/3.3kV 유입변압기의 소손패턴 해석 및 발화원인 판정에 관한 연구 (Study on the Damage Pattern Analysis of a 3 Phase 22.9/3.3kV Oil Immersed Transformer and Judgment of the Cause of Its Ignition)

  • 최충석
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1274-1279
    • /
    • 2011
  • The purpose of this paper is to present the manufacturing defect and damage pattern of a 3 phase 22.9/3.3kV oil immersed transformer, as well as to present an objective basis for the prevention of a similar accident and to secure data for the settlement of PL related disputes. It was found that in order to prevent the occurrence of accidents to transformers, insulating oil analysis, thermal image measurement, and corona discharge diagnosis, etc., were performed by establishing relevant regulation. The result of analysis performed on the external appearance of a transformer to which an accident occurred, the internal insulation resistance and protection system, etc., showed that most of the analysis items were judged to be acceptable. However, it was found that the insulation characteristics between the primary winding and the enclosure, those between the ground and the secondary winding, and those between the primary and secondary windings were inappropriate due to an insulating oil leak caused by damage to the pressure relief valve. From the analysis of the acidity values measured over the past 5 years, it is thought that an increase in carbon dioxide (CO2) caused an increase in the temperature inside the transformer and the increase in the ethylene gas increased the possibility of ignition. Even though 17 years have passed since the transformer was installed, it was found that the system's design, manufacture, maintenance and management have been performed well and the insulating paper was in good condition, and that there was no trace of public access or vandalism. However, in the case of transformers to which accidents have occurred, a melted area between the upper and the intermediate bobbins of the W-phase secondary winding as well as between its intermediate and lower bobbins. It can be seen that a V-pattern was formed at the carbonized area of the transformer and that the depth of the carbonization is deeper at the upper side than the lower side. In addition, it was found that physical bending and deformation occurred inside the secondary winding due to non-uniform pressure while performing transformer winding work. Therefore, since it is obvious that the accident occurred due to a manufacturing defect (winding work defect), it is thought that the manufacturer of the transformer is responsible for the accident and that it is lawful for the manufacture to investigate and prove the concrete cause of the accident according to the Product Liability Law (PLL).

A New Three Winding Coupled Inductor-Assisted High Frequency Boost Chopper Type DC-DC Power Converter with a High Voltage Conversion Ratio

  • Ahmed Tarek;Nagai Shinichiro;Hiraki Eiji;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.99-103
    • /
    • 2005
  • In this paper, a novel circuit topology of a three-winding coupling inductor-assisting a high-frequency PWM boost chopper type DC-DC power converter with a high boost voltage conversion ratio and low switch voltage stress is proposed for the new energy interfaced DC power conditioner in solar photovoltaic and fuel cell generation systems. The operating principle in a steady state is described by using its equivalent circuits under the practical condition of energy processing of a lossless capacitive snubber. The newly-proposed power MOSFET boost chopper type DC-DC power converter with the three-winding coupled inductor type transformer and a single lossless capacitor snubber is built and tested for an output power of 500W. Utilizing the lower voltage and internal resistance power MOSFET switch in the proposed PWM boost chopper type DC-DC power converter can reduce the conduction losses of the active power switch compared to the conventional model. Therefore, the total actual power conversion efficiency under a condition of the nominal rated output power is estimated to be 81.1 %, which is 3.7% higher than the conventional PWM boost chopper DC power conversion circuit topology.

이음매 없는 일체형 라이너를 갖는 복합재 압력용기의 피로수명 향상에 대한 연구 (A Study on Improving Fatigue Life for Composite Cylinder with Seamless Integrated Liner)

  • 김효준
    • 한국가스학회지
    • /
    • 제17권6호
    • /
    • pp.46-51
    • /
    • 2013
  • 복합재 압력용기는 높은 비강성과 비강도 그리고 내피로성으로 수소연료전지자동차와 천연가스자동차에 사용된다. 이음매가 없는 일체형 라이너를 갖는 복합재 압력용기는 고강도 탄소섬유와 에폭시 레진으로 라이너 전체를 감싼다. 본 연구에서는 구조적으로 취약한 너클 부위와 압축잔류응력을 고려하여 필라멘트 와인딩 패턴과 자긴압력 설계 기법을 제시하였다. 복합재 압력용기 시제품에 대한 압력반복시험을 통해 제안된 방법을 검증한다.

등가회로법에 의한 커패시터 구동 단상 유도전동기의 특성해석 (Characteristic Analysis of Capacitor Run Single-Phase Induction Motor by Equivalent Circuit Method)

  • 좌종근;김호민;김도진
    • 전기학회논문지P
    • /
    • 제60권4호
    • /
    • pp.220-226
    • /
    • 2011
  • This paper proposes a straightforward method of analyzing the operation characteristics for the capacitor run single-phase induction motor from the traditional equivalent circuit based on the revolving field theory. The proposed method consists of five procedures as follows: mechanical loss segregation, iron loss segregation and calculation of the equivalent circuit parameters, recalculation of parameters of the main winding side, calculation of the auxiliary winding magnetizing reactance and effective turn ratio, and analyzing the operation characteristics for this motor. When the characteristics are analyzed, the segregated mechanical and iron losses are considered as a loss resistance across input terminals of the equivalent circuit for the analysis. The validity of the proposed method is verified from the comparison between the computed results and the experimental ones for the operation characteristics.

등가 자기회로를 이용한 집중권 전동기의 치폭 요크폭 최적설계 (Optimal Design of Tooth and Yoke Width Using Equivalent Magnetic Circuit in Concentrated Winding Motor)

  • 김도진;권순오;홍정표;남혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.869_870
    • /
    • 2009
  • This paper presents optimal design of tooth and yoke width for increasing torque density when designing concentrated winding Interior Permanent Magnet Synchronous Motor(IPMSM) which is used currently. In case of IPM, characteristic of motor chages according to saturation, thus design consib dering saturation should be done. This paper proposed method to decide tooth and yoke width using magnetic equivalent circuit with calculated magnetic resistance. This method provide less effort and time than FEM using optimal design when deciding tooth and yoke width. Proposed method and FEM are compared and verified.

  • PDF

무전극 형광램프용 페라이트에 따른 전기적 및 광학적 특성 (Electrical and Optical Characteristics by Ferrite for Electrodeless Fluorescent Lamp)

  • 백광현;양종경;이종찬;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.200-206
    • /
    • 2006
  • An electric power efficiency of electrodeless fluorescent lamp depens on a big relative property of gas, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. in lamp. We used magnetic substance that opens self-examination material of electrodeless fluorescent lamp antenna. We used Mn-Zn type as the Ferrite. We have examined resistance, impedance and Q-factor's frequency characteristic by ferrite. Coil turns were changed from 13 to 15 turns to recognize brightness change of lamp by winding number. Optical equipment (LS-100) was used to measure brightness. We could know Q-factor's difference according to material is important part of antenna design. When an electrodeless fluorescent lamp was made using T company's PE22, it showed the highest brightness. As number of winding is increased the brightness increased, and starting characteristic became good.