• Title/Summary/Keyword: Winding Pattern

Search Result 72, Processing Time 0.026 seconds

Auto-Detection of Stator Winding Fault of Small Induction Motor using LabVIEW (LabVIEW를 이용한 소형 유도전동기의 권선고장 자동진단)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Woo, Hyeok-Jae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.202-206
    • /
    • 2006
  • In this paper, an auto detection method of stator winding fault of small induction motor is suggested. The Park's vector pattern which is obtained from 3-phase current signal by d-q transforming, is very good to detect winding fault. Comparing the Park's vector pattern of testing motor with its of healthy motor, the Park's vector pattern of fault motor is became an ellipse and the asymmetry is increased by the winding fault series. So for detecting the dis-symmetry, id-filtered function, Min-value, and Max-value are suggested for auto detecting. Using LabVIEW programing, 3-phase healthy motor and several kind of winding fault motors are tested and the test results are shown that the suggested method can gives us a possibility of an auto detecting winding fault.

Study on Distortion Ratio Calculation of Park's Vector Pattern for Diagnosis of Stator Winding Fault of Induction Motor (유도전동기의 고정자 권선고장 진단을 위한 팍스벡터 패턴의 왜곡률 연산에 대한 연구)

  • Yang, Chul-Oh;Park, Kyu-Nam;Song, Myung-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.643-649
    • /
    • 2012
  • The diagnosis technique of stator winding faults based on Motor Current Signature Analysis(MCSA) was suggested. Park's vector pattern, the circle that is drawn by d-q transformed currents($i_d$, $i_q$), is widely used for stator winding faults detection. The current Distortion Ratio(DR), defined by the ratio of max axis and min axis of ellipse of Park's vector's pattern, was more simple and powerful method than the Park's vector pattern. In this study, a calculation method of distortion ratio of Park's vector pattern was suggested for auto diagnosis of stator winding short fault and usefulness of suggested calculation method of distortion ratio was verified through simulation using LabVIEW program.

A Study on Feature Extraction of Fault Signal for Stator Winding using Epoxy/Mica Coupler (에폭시/마이카 커플러를 이용한 고정자권선 결함신호 특징추출에 관한연구)

  • Park, Jae-Jun;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.225-226
    • /
    • 2005
  • In this Study, we have acquired 5-simulation Fault types Signals of high voltage Motor stator winding using epoxy/mica coupler. In order to know stator winding fault type using fault signals, we have performed feature extraction to apply wavelet transform technique. we have obtained skewness and kurtosis as statistical parameters of fault signal pattern from non deterioration state winding. We have know that 5 fault signals types have done an exponential function pattern shape but individually fault a class widely was different each other a signal waveform of pattern.

  • PDF

Characteristics of GRP tube using Composite Hollow Bushing by Filament Winding (Filament Winding에 의한 Composite Hollow Bushing용 GRP tube의 특성)

  • Cho, Han-Goo;Kang, Hyung-Kyung;Yoo, Dea-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.378-379
    • /
    • 2008
  • Recently, composite hollow bushings have been increasingly employed mainly from the various characteristics. Composite bushings are superior to porcelain bushings in several respects, including lighter weight, better anti-pollution and anti-explosion properties, and easer manufacturing. Filament wound GRP tubes which have various winding angle were manufactured by using a filament winding machine. This paper will show some design issues and winding condition for composite bushing. And, results show that the winding condition of composite GRP tubes can be used to improved their bending strength and pressure, For bending and pressure tested, tubes with the hybrid winding pattern show higher strength than those of unit winding pattern. Also, the influence of absorption was evaluated through such as measurement of the dye penetration test and water diffusion test, also aspects of surface state using scanning electron microscopy.

  • PDF

Stator Winding Fault Diagnosis in Small Three-Phase Induction Motors by Park's Vector Approach (Park's Vector 기법을 이용한 소형 3상 유도 전동기의 권선 고장 진단)

  • 박규남;한민관;우혁재;송명현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.6
    • /
    • pp.1291-1296
    • /
    • 2003
  • This paper deals with efficient diagnostic for stator winding fault of 3-phase induction motor using a current Park's vector approach. This method firstly transforms 3-phase stator current to vertical axis current and horizontal axis current of Park's Vector, and then obtains the each Park's Vector Pattern and detects stator winding fault by comparing to Park's Vector Pattern of healthy and fault. Experimental results, obtained by using induction motor having inter-turn fault of 2, 10, 20 turn, demonstrate the effectiveness of the proposed technique, for detecting the presence of stator winding fault under 25%, 50%, and 100% of full load condition.

Interpretation of Influence Winding Short Phase of Induction Motor to Distortion Ratio of Park's Vector Pattern (유도전동기의 권선 단락 상에 따른 팍스 벡터 패턴 왜곡률의 영향 해석)

  • Yang, Chul-Oh;Kim, Jong-Sun;Kim, Jun-Young;Park, Kyu-Nam;Song, Myung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2075-2076
    • /
    • 2011
  • The stator winding faults diagnosis technique based on MCSA is as follows. Firstly, collecting the 3 phase motor currents, that signal is transformed by (d-q transform, $i_d$, $i_q$). Park's vector pattern, the circle that is down by d-q transformed currents($i_d$, $i_q$). The circle is widely used for stator winding faults detection. The current distortion ratio(DR), defined by the ratio of max-axis and min-axis of ellipse of Park's vector's pattern. In this study, distortion ratio of Park's vector pattern is suggested for Auto diagnosis of stator winding short fault and usefulness of distortion ratio is verified through simulation using LabVIEW program.

  • PDF

Winding Fault Diagnosis for BLDC Motor using MCSA (MCSA를 이용한 BLDC 전동기의 고정자 권선 고장 진단)

  • Lee, Dae-Seong;Yang, Chul-Oh;Kim, Jun-Young;Kim, Dae-Hong;Moon, Yong-Seon;Park, Kyu-Nam;Song, Myung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1876-1877
    • /
    • 2011
  • In this paper, a winding fault diagnosis method base on MCSA(Motor Current Signature Analysis) for BLDC motor is proposed. This method is programmed by LabVIEW for winding fault diagnosis. For winding fault diagnosis, two types of winding fault(shorted turn at one pole, shorted turn at two pole in same phase) are put intentionally in on phase. The motor current is collected by hole sensor, and transformed by the Park's transform, and then the Park's Vector Pattern are obtained, Usually this pattern is formed an ellipse, so a proper threshold value of distortion ratio(the ratio of the shortest axis and longest axis of ellipse) is suggested for winding faults diagnosis.

  • PDF

Winding Fault Diagnosis of Induction Motor Using Neural Network

  • Song Myung-Hyun;Park Kyu-Nam;Woo Hyeok-Jae;Lee Tae-Hun;Han Min-Kwan
    • Journal of information and communication convergence engineering
    • /
    • v.3 no.2
    • /
    • pp.105-109
    • /
    • 2005
  • This paper proposed a fault diagnosis technique of induction motors winding fault based on an artificial neural network (ANN). This method used Park's vector pattern as input data of ANN. The ANN are firstly learned using this pattern, and then classify between 'healthy' and 'winding fault' (with 2, 10, and 20 shorted turn) induction motor under 0, 50, and $100\%$ load condition. Also the possibility of classification of untrained turn-fault and load condition are tested. The proposed method has been experimentally tested on a 3-phase, 1 HP squirrel-cage induction motor. The obtained results provided a high level of accuracy especially in small turn fault, and showed that it is a reliable method for industrial application

PREPREG 제작 방식에 의한 압력용기(STEB)의 시험 및 고찰

  • 이원복;손원경;유광호
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.30-30
    • /
    • 1997
  • 국내에서는 시도되지 않았던 조립식 맨드렐 및 prepreg 제작 방식을 적용하여 filament winding machine으로 압력 용기(STEB)를 제작, 음향 방출 측정 장비 및 strain gage 등을 부착한 수압 시험으로 압력용기의 구조적 건전성 예측 및 파열 압력을 측정하여 성능을 분석하였다. 동일한 winding pattern 및 조건하에 prepreg winding과 wet winding 방식을 적용하여 제작한 압력 용기의 성능을 비교하였고, prepreg winding의 설계 조건, 공정 변화를 통해 제작한 압력 용기의 파열 압력 및 형태를 분석하였다. 이러한 winding 조건들에 따라 제작된 압력용기는 최종적으로 PR(Performance ratio) 값을 산출하고, 이를 통하여 prepreg 제작 방식의 장단점, 제작에 필요한 설계 조건 및 기초 자료 등을 고찰하여 보았다.

  • PDF

Winding Design of Pole Change Motor for Harminics Reduction (고조파 저감을 위한 극변환 전동기의 권선 설계)

  • Nam, Hyuk;Hong, Jung-Pyo;Jeong, Seung-Kyu;Jung, Tae-Uk;Baek, Seung-Myun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.910-912
    • /
    • 2001
  • The winding design of a capacitor-run single-phase induction motor for changing two poles(2-/4-pole) is proposed for reducing the harmonics of Magneto Motive Force(MMF) in the airgap at 2-role. To improve motor performance, it is important to analyze exactly the harmonics and design the winding pattern for its harmonics reduction. The winding design method to reduce the harmonics is suggested in this paper and its characteristics are analyzed by using equivalent circuit considering harmonic components. The various performances of the pole change motor with the proposed winding pattern are compared with the experimental results.

  • PDF