• Title/Summary/Keyword: WindSIM

Search Result 379, Processing Time 0.024 seconds

The Economic Value Analysis of the Potential Wind Farm Site Using the Black-Scholes Model (블랙 숄즈 모델을 이용한 잠재적 풍력발전 위치의 경제적 가치분석)

  • Jaehun Sim
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.45 no.4
    • /
    • pp.21-30
    • /
    • 2022
  • To mitigate the environmental impacts of the energy sector, the government of South Korea has made a continuous effort to facilitate the development and commercialization of renewable energy. As a result, the efficiency of renewable energy plants is not a consideration in the potential site selection process. To contribute to the overall sustainability of this increasingly important sector, this study utilizes the Black-Scholes model to evaluate the economic value of potential sites for off-site wind farms, while analyzing the environmental mitigation of these potential sites in terms of carbon emission reduction. In order to incorporate the importance of flexibility and uncertainty factors in the evaluation process, this study has developed a site evaluation model focused on system dynamics and real option approaches that compares the expected revenue and expected cost during the life cycle of off-site wind farm sites. Using sensitivity analysis, this study further investigates two uncertainty factors (namely, investment cost and wind energy production) on the economic value and carbon emission reduction of potential wind farm locations.

A Study on a Wind Turbine Data Logger System based on WiFi for Meteorological Resource Measurement (기상자원 측정을 위한 와이파이 기반의 풍력용 데이터로거 시스템에 관한 연구)

  • Jung, Se-Hoon;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.55-64
    • /
    • 2015
  • Wind turbine market is showed height growth rate of about 30% for year, and is increasingly growing. Total rate of domestic wind turbine installation is showing share of 0.2% of the global market that is 380MW. However, wind turbine installed in domestic are foreign product more than 90%. Similarly, Datalogger of pretest system for ocean wind turbine plant installation has been leaked huge cost to abroad by mostly abroad company product. In this paper, we proposed pretest weather resource measurement system for efficiency and investment cost cutting of wind turbine construction work. Preset weather resource measurement system is ocean weather resource measurement datalogger based on wireless communication(wifi) that have consist of hardware and software(wind rose) that is able to monitoring as datalogger of wireless bridge and battery state, wind direction, wind speed, temperature, humidity, radiation around weather tower and is able to analysis of measured data.

Wind Fragility for Urban Street Tree in Korea (강풍 발생 시 국내 가로수의 취약성 분석)

  • Sim, Viriyavudh;Jung, WooYoung
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.298-304
    • /
    • 2019
  • In this paper, the analytical method to derive wind fragility for urban street tree in Korea was shown. Monte Carlo Simulation method was used to determine the probability of failure for urban street tree. This probability result was used to determine wind fragility parameters for four types of tree based on the study of street tree species in urban area in Daegu, Korea. Wind fragility for street tree was presented in terms of median capacity and standard deviation of the natural logarithm of the capacity. Results showed that the dominant factor affecting the probability of failure of tree under wind load was their diameter. Moreover, amongst the four types of tree chosen, the tree with height 7m and diameter 35cm had the lowest probability of failure under wind loading, whereas the tree with height 8m and diameter 30cm could resist the least wind loading. The median failure wind speed for urban street tree with height 7m were 43.8m/s and 50.6m/s for diameter 30cm and 35cm, respectively. Also, for tree with height 8m, their median failure wind speeds were 38.7m/s and 45.4m/s for tree with diameter 30cm and 35cm, respectively.

Local Wind Field Simulation over Coastal Areas Using Windprofiler Data (윈드프로파일러 자료를 이용한 연안 지역 국지 바람장 모의)

  • Kim, Min-Seong;Kim, Kwang-Ho;Kim, Park-Sa;Kang, Dong-Hwan;Kwon, Byung Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.2
    • /
    • pp.195-204
    • /
    • 2016
  • In this paper, the applicability and usefulness of windprofiler input data were investigated to generate three dimensional wind field. A logical diagnostic model CALMET with windprofiler data at ten sites and with weather forecasting model WRF output was evaluated by statistically comparing with the radiosonde data at eight sites. The horizontal wind speed from CALMET simulated with hourly windprofiler data is in good agreement with radiosonde observations within 1.5 m/s of the root mean square error, especially local circulation of wind such as sea breeze over the coastal region. The root mean square error of wind direction ranged $50^{\circ}{\sim}70^{\circ}$ is due to the wind direction error from the windprofiler polluted by ground clutters. Since the exact wind can be produced quickly and accurately in most of the altitude with windprofiler data on CALMET, we expect the method presented in this study to be useful for the monitoring of safe environment as well as weather in the coastal zone.

Analysis of Local Wind in Busan Metropolitan area According to Wind Sector Division - Part I : Coarse Division of Wind Sector using Meteorological Observation Data - (바람권역 구분을 통한 부산지역 국지바람 분석 - Part I : 기상관측 자료를 이용한 바람권역 대분류 -)

  • Lee, Hwa-Woon;Jung, Woo-Sik;Leem, Heon-Ho;Lee, Kwi-Ok;Choi, Hyun-Jung;Ji, Hyo-Eun;Lee, Hyun-Ju;Sung, Kyoung-Hee;Do, Woo-Gon
    • Journal of Environmental Science International
    • /
    • v.15 no.9
    • /
    • pp.835-846
    • /
    • 2006
  • In this study, climate analysis and wind sector division were conducted for a propriety assessment to determine the location of air quality monitoring sites in the Busan metropolitan area. The results based on the meteorological data$(2000{\sim}2004)$ indicated hat air temperature is strongly correlated between 9 atmospheric monitoring sites, while wind speed and direction are not. This is because wind is strongly affected by the surrounding terrain and the obstacles such as building and tree. in the next stage, we performed cluster analysis to divide wind sector over the Busan metropolitan area. The cluster analysis showed that the Busan metropolitan area is divided into 6 wind sectors. However 1 downtown and 2 suburbs an area covering significantly broad region in Busan are not divided into independent sectors, because of the absence of atmospheric monitoring site. As such, the Busan metropolitan area is finally divided into 9 sectors.

The Relationship of Froude Number and Developed Cloud Band Locations Near Yeongdong Region Under the Siberian High Pressure System (시베리아 고기압 영향으로 영동지역 부근에서 발달한 구름대의 위치와 Froude 수와의 관계)

  • Kim, Yu-Jin;Kim, Man-Ki;Lee, Jae Gyoo
    • Atmosphere
    • /
    • v.29 no.3
    • /
    • pp.325-342
    • /
    • 2019
  • Precipitation and no-precipitation events under the influence of the Siberian high pressure system in Yeondong region, were analysed and classified as four types [obvious precipitation event (OP) type, obvious no-precipitation event (ON) type, ambiguous precipitation event (AP) type and ambiguous no-precipitation event (AN) type], according to the easiness in determining whether to have precipitation or not in Yeongdong region, to help in improving the forecast skill. Concerning the synoptic pressure pattern, for OP type, the ridge of Siberian high extends from Lake Baikal toward Northeast China, and there is a northerly wind upstream of the northern mountain complex (located near the Korean-Chinese border). On the other hand, for ON type, the ridge of Siberian high extends southeastward from Lake Baikal, and there is a westerly wind upstream of the northern mountain complex. The pressure pattern of AP type was similar to the OP type and that of AN type was also similar to ON type. Thus it was difficult to differentiate AP type and OP type and AN type and ON type based on the synoptic pressure pattern only. The four types were determined by U (wind speed normal to the Taebaek mountains) and Froude number (FN). That is, for OP type, average FN and U at Yeongdong coast are ~2.0 and ${\sim}6m\;s^{-1}$, and those at Yeongseo region are 0.0 and $0.1m\;s^{-1}$, respectively. On the contrary, for ON type, average FN and U at Yeongdong coast are 0.0 and $0.2m\;s^{-1}$, and those at Yeongseo region are ~1.0 and ${\sim}4m\;s^{-1}$, respectively. For AP type, average FN and U at Yeongdong coast are ~1.0 and ${\sim}4m\;s^{-1}$, and those at Yeongseo region are 0.0 and $0.2m\;s^{-1}$, whereas for AN type, average FN and U at Yeongdong coast are 0.1 and $0.6m\;s^{-1}$ and those at Yeongseo region are ~1.0 and ${\sim}3m\;s^{-1}$, respectively. Based on the result, a schematic diagram for each type was suggested.

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.

A Study on the Sensitivity Analysis of Line Source Air Quality Models (移動汚染源에 대한 大氣擴散模型의 感應度 分析에 관한 硏究 (HIWAY2, PAL, CALINE3 模型을 對象으로))

  • 김선태;김병태;김정욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.1-10
    • /
    • 1989
  • The sensitivity analysis is a method to quantify to what extent the output of a model changes with the values of input parameters. This will lead to increase model accuracy through measurement validation. Three line source air quality models, HIWAY 2, PAL, and CALINE 3 were selected for this study. The input parameters analysed included wind speed, wind direction, stability, emission rate, mixing height, receptor distance, initial dispersion coefficient, surface roughness, and averaging time. It turned out that PAL model generally showed higher concentration than other two models, and that between CALINE 3 and HIWAY 2, CALINE 3 showed higher concentration than HIWAY 2 model near the line sources, but beyond a certain downwind distances HIWAY 2 model showed higher concentration. The modesl were very sensitive to wind speed especially in the range of 0 $\sim$ 1 m/s and to wind direction near the parallel wind to streets. In case of emission rate, the output concentration was directly proportional to these input parameters. And the sensitivity of the input parameters such as stability, mixing height, initial dispersion coefficient, surface roughness, and averaging time were not very significant.

  • PDF

A Wind Turbine Simulator for Doubly-Fed Induction-type Generator with Automatic Operation Mode Change during Wind Speed Variation (가변 풍속시 운전모드 절환을 고려한 이중여자 유도형 풍력발전기의 시뮬레이터)

  • Song, Seung-Ho;Sim, Dong-Joon;Jeong, Byoung-Chang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.349-360
    • /
    • 2006
  • Controller for doubly-fed induction-type wind generation system should be designed with mechanical power on blade. The controller in this paper consists of upper level controller and lower level controller. The upper level controller determines operating modes according to mechanical input power and calculates proper reference values. There are 4 operating modes - minimum speed control, variable torque control, torque limit control and idle mode. The lower level controller performs current regulated PWM control of rotor-side converter and grid-side inverter. A wind turbine simulator is implemented using doubly-fed induction-type generator and DSP based back-to-back converter to verify the performance of designed controller experimentally.