• Title/Summary/Keyword: Wind load condition

Search Result 186, Processing Time 0.024 seconds

A Study of Non-Working Days Estimation in the High-rise Construction with Wind Load Data by Radiosonde

  • Kim, Se-Hoon;Kim, Yea-Sang;Shin, Hyuk;Kim, Hye-Jin
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.188-191
    • /
    • 2015
  • This study is based on the data of velocity actually measured at varied the heights in the last 3 years. As mentioned in the World Meteorological Monitoring Plan(World Weather Watch: WWW), using the meteorological data by radiosonde can calculate the probability of velocity greater than 10m/s which is the standard beginning point of non-working condition by wind. The height is divided into sections, with 100m for each section starting from the ocean surface up to 700m high. The data measured at each section could be used for estimating and predicting the probability of non-working days for the construction nearby. For example, the data of Osan region is expected to be applicable for the project located in Seoul which has similar geographical conditions. As comparing the velocity varied with height, non-working days calculated basing on the measured data shows a variation of from -0.3 to +64 days. However, this study use Weibull distribution which considered more reliable, the result is expected to be more useful, as the data was all actually measured in the real conditions.

  • PDF

Development of Probabilistic Wind Load Models (국내 풍하중의 확률적 모형 개발)

  • 김상효;배규웅;박홍석
    • Computational Structural Engineering
    • /
    • v.3 no.2
    • /
    • pp.109-115
    • /
    • 1990
  • The probabilistic characteristics of wind loads have been analyzed using statistical data on wind speeds, pressure coefficient, exposure coefficient, and gust factor. The wind speed data collected at 25 nationwide weather stations have been modified to be consistent in measuring height, exposure condition as well as averaging time. Having performed Monte Carlo simulation for various heights and site conditions, the statistical models of wind loads were determined, in which Type-I extreme value distribution has been applied. The models also incorporate a reduction factor of 0.85 to account for the reduced probability that the maximum wind speed will occur in a direction most unfavorable to the response of structure.

  • PDF

Development of the Bus Duct Installation System for Wind Tower (풍력타워용 부스덕트 포설시스템 개발)

  • Rhee, Huinam;Lee, Joon Keun;Kim, Bong-Seok;Park, Seong-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.219-226
    • /
    • 2014
  • A bus duct system for wind tower is introduced. A marine cable has been widely used in wind tower or various offshore structures. However, as the electric load capacity is increases, large number of cable lines must be used to cover the huge amount of electric capacities. Therefore, the installation of the cable lines becomes very difficult due to the heavy weight and volume of the cables. On the other hand, by using a single bus duct system line, the power capacity amount of 16 cables can be delivered with significantly compacted form. However, unlike flexible cables, the bus duct is relatively stiff which could generate the resonance phenomenon in the operating condition of the wind tower. In this study, the vibration characteristics of the bus duct are investigated and its long-term reliability during the life time of the wind tower is verified.

Correlation Analysis of Wind and Solar Power Generation Pattern for Modeling of Renewable Energy (신재생에너지 모델링을 위한 풍력 및 태양광 발전 출력 패턴 상관관계 분석)

  • Kim, Min-Jeong;Park, Young-Sik;Park, Jong-Bae;Roh, Jae-Hyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1823-1831
    • /
    • 2011
  • When the RPS(Renewable Portfolio Standards) becomes effective in 2012, the use of renewable energy will be dramatically increased. However, there are no production simulations and demand supply programs that reflect the characteristics of the renewable energy. This paper analyzes correlations of the domestic wind power and solar power generation pattern in different areas and those of these sources' output and load pattern. Based on the regional correlation analysis, an appropriate method that uses a average output of the renewable energy or another modeling that takes account of uncertainty could be selected. Because it's output is dependent on weather condition, we can not control the generation of renewable energy, that is the reason why the correlation between the load and output pattern of sources can be helpful to determine whether the renewable energy is modeled as a generator or load modifier. Through this analysis, a basis will be provided in order to properly model the renewable energy source.

WIND PRESSURE TRANSIENTS ON PLATFORM SCREEN DOOR OF SIDE PLATFORMS IN A SUBWAY STAT10N CAUSED BY PASSING TRAINS (상대식 승강장에서 열차 운행에 의한 지하철 승강장 스크린 도어 풍압해석)

  • Lee, Myung-Sung;Lee, Sang-Hyuk;Hur, Nahm-Keon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.64-67
    • /
    • 2007
  • In the present study, the wind pressure transients on platform screen door in side platforms caused by passing trains have been investigated numerically. The transient compressible 3-D full Navier-Stokes solution is obtained with actual operational condition of subway train and the moving mesh technique is adopted considering the train movement. To achieve more accurate analysis, the entrance and exit tunnel of platform are included in a computational domain and detailed shape of train is also modeled Numerical analyses were conducted on five operational condition which are different velocity variation of subway train, existence of stationary train and passing each other trains. The results show that pressure load on platform screen door is maximized when the two trains are passing each other. It is also seen from the computational results that the maximum pressure variation was found to be satisfactory to various foreign standards.

  • PDF

Realtime Monitoring system of Residential Photovoltaic system (태양광-풍력 복합발전시스템의 출력제어 특성에 관한 연구)

  • Lee J.I.;Suh J.S.;Yoon P.H.;Cha I.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.933-937
    • /
    • 2003
  • The development of the solar and the wind power energy are necessary since the future alternative energies that have no pollution and no limitation are restricted. Currently power generation system of MW scale has been developed, but it still has a few faults with the weather condition. In order to solve these existing problems, combined generation system of photovoltaic(400w) and wind power generation system(400w) was suggested. It combines wind power and solar energy to have the supporting effect from each other However, since even combined generation system cannot always generate stable output with ever-changing weather condition, power compensation device that uses elastic energy of spiral spring to combined generation system was also added for the present study. In an experiment, when output of system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator

  • PDF

A Study on the Discontinuous Energy Ceneration System for Power Compensation (불연속 에너지 발생장치의 에너지 보상 시스템에 대한 연구)

  • Lee, Jeong-Il;Lim, Jung-Yeol;Kang, Byung-Bog;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.133-138
    • /
    • 2002
  • The developments of the solar and the wind power energy are necessary since the future alternative energies that have no pollution and no limitation are restricted. Currently power generation system of MW scale has been developed, but it still has a few faults with the weather condition. In order to solve these existing problems, combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, since even combined generation system cannot always generate stable output with ever-changing weather condition, power compensation device that uses elastic energy of spiral spring to combined generation system was also added for the present study. In an experiment, when output of system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.

  • PDF

Structural Analysis and Proof Test of Composite Rotor Blades for Wind Turbine (풍력발전기용 복합재 블레이드의 구조해석 및 인증시험)

  • Park, Sun-Ho;Han, Kyung-Seop
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.299-302
    • /
    • 2008
  • GFRP based composite rotor blades were developed for 750kW & 2MW wind turbines. The blade sectional geometry was designed to have a general shell-spar and shear web structure. For verifying the structural safety under all relevant extreme loads specified in the GL guidelines, the structural analysis of the rotor blades was performed using commercial FEM codes. The static load carrying capacity, blade tip deflections and natural frequencies were evaluated to satisfy the strength and stability requirements. Full-scale proof tests of rotor blades were carried out with optical fiber sensors for real-time condition monitoring. Finally, the prototype of each rotor blade passed all proof tests for GL certification.

  • PDF

Development of combined generation systems that power storage apparatus is applied (동력저장장치가 적용된 복합발전시스템의 개발)

  • Lee, Jeong-Il;Seo, Jang-Soo;Kang, Byung-Bog;Cha, In-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.4
    • /
    • pp.169-174
    • /
    • 2002
  • The developments of the solar and the wind power energy are neccessary since the future alternative energies that have no pollution and no limitation are restricted. Currently power generation system of existing problems, combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, weather condition, power compensation device that uses elastic energy of spiral spring to combined generation system was also added for the present study. In an experiment, when output of system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.

A study on the action mechanism of internal pressures in straight-cone steel cooling tower under two-way coupling between wind and rain

  • Ke, S.T.;Du, L.Y.;Ge, Y.J.;Yang, Q.;Wang, H.;Tamura, Y.
    • Wind and Structures
    • /
    • v.27 no.1
    • /
    • pp.11-27
    • /
    • 2018
  • The straight-cone steel cooling tower is a novel type of structure, which has a distinct aerodynamic distribution on the internal surface of the tower cylinder compared with conventional hyperbolic concrete cooling towers. Especially in the extreme weather conditions of strong wind and heavy rain, heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind, but existing studies mainly focus on the impact effect brought by wind-driven rain to structure surface. In addition, for the indirect air cooled cooling tower, different additional ventilation rate of shutters produces a considerable interference to air movement inside the tower and also to the action mechanism of loads. To solve the problem, a straight-cone steel cooling towerstanding 189 m high and currently being constructed is taken as the research object in this study. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed with continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind sped and rainfall intensity on flow field mechanism, the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower cylinder is analyzed. On this basis, the internal pressures of the cooling tower under the most unfavorable working condition are compared between four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the 3D effect of equivalent internal pressure coefficient is the most significant when considering two-way coupling between wind and rain. Additional load imposed by raindrops on the internal surface of the tower accounts for an extremely small proportion of total wind load, the maximum being only 0.245%. This occurs under the combination of 20 m/s wind velocity and 200 mm/h rainfall intensity. Ventilation rate of shutters not only changes the air movement inside the tower, but also affects the accumulated amount and distribution of raindrops on the internal surface.