• 제목/요약/키워드: Wind heating

검색결과 163건 처리시간 0.03초

풍력발전기 Air Guide 위치별 온도상승 해석 (Analysis of Temperature Rise on the Air-Guide's Position of Wind Power Generator)

  • 한창우;김현재;권기영;이학성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.282-285
    • /
    • 2008
  • In this paper, the numerical analysis of the model without air-guide was carried out in wind power generator. From numerical results, the temperature rise was not satisfied for the class F insulation and the non-uniformity of temperature distribution was a wide difference in heating elements. To improve these problems, the air-guide was installed in front of the coil head of non-drive end(NDE). The short distance between coil head and air-guide was more effective than long distance in cooling performance. Compared to that of the preliminary design, it was found that the cooling performance of the modification design was improved about 12%.

  • PDF

Factors Affecting Performance of a Proto type Windheat Generation System

  • Kim Y.J.;Yun J.H.;Ryou Y.S.;Kang G.C.;Paek Y.;Kang Y.K.
    • Agricultural and Biosystems Engineering
    • /
    • 제6권1호
    • /
    • pp.22-26
    • /
    • 2005
  • A wind-heat generation system was developed and the system consisted of an electric motor, a heat generation drum, a heat exchanger, two circulation pumps and a water storage tank. The heat generation drum is an essential element determining performance of the system. Frictional heat was generated by rotation of a rotor in the drum filled with a working fluid, and the heat stored in the fluid was used to increase water temperature through the heat exchanger. Effects of some factors such as rotor shape, kind and amount of working fluid, rotor rpm and water flow rate in the heat exchanger, affecting the system performance were investigated. Amounts of heat generated were varied, ranging from 126,000 to 32,760 kJ/hr, depending on combination of the factors. Statistical analysis using GLM procedure revealed that the most influential factor to decide the system performance was amount of the fluid in the drum. Experiments showed that the faster the speed of the rotor, the greater heat was obtained. The greatest efficiency of the heat generation system, electric power consumption rate vs gained heat amount of water, was about 70%. Though the heat amount was not enough for plant bed heating of a 0.1-ha greenhouse, the system would be promising if some supplementary heat source such as air- water heat pump is added.

  • PDF

Contributions of Heating and Forcing to the High-Latitude Lower Thermosphere: Dependence on the Interplanetary Magnetic Field

  • Kwak, Young-Sil;Richmond, Arthur;Ahn, Byung-Ho;Cho, Kyung-Suk
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권3호
    • /
    • pp.205-212
    • /
    • 2010
  • To better understand the physical processes that maintain the high-latitude lower thermospheric dynamics, we have identified relative contributions of the momentum forcing and the heating to the high-latitude lower thermospheric winds depending on the interplanetary magnetic field (IMF) and altitude. For this study, we performed a term analysis of the potential vorticity equation for the high-latitude neutral wind field in the lower thermosphere during the southern summertime for different IMF conditions, with the aid of the National Center for Atmospheric Research Thermosphere-Ionosphere Electrodynamics General Circulation Model (NCAR-TIEGCM). Difference potential vorticity forcing and heating terms, obtained by subtracting values with zero IMF from those with non-zero IMF, are influenced by the IMF conditions. The difference forcing is more significant for strong IMF $B_y$ condition than for strong IMF $B_z$ condition. For negative or positive $B_y$ conditions, the difference forcings in the polar cap are larger by a factor of about 2 than those in the auroral region. The difference heating is the most significant for negative IMF $B_z$ condition, and the difference heatings in the auroral region are larger by a factor of about 1.5 than those in the polar cap region. The magnitudes of the difference forcing and heating decrease rapidly with descending altitudes. It is confirmed that the contribution of the forcing to the high-latitude lower thermospheric dynamics is stronger than the contribution of the heating to it. Especially, it is obvious that the contribution of the forcing to the dynamics is much larger in the polar cap region than in the auroral region and at higher altitude than at lower altitude. It is evident that when $B_z$ is negative condition the contribution of the forcing is the lowest and the contribution of the heating is the highest among the different IMF conditions.

임해지역의 개발이 기상장에 미치는 영향예측 (Numerical Simulation of Effect on Atmospheric Flow Field by Development of Coastal Area)

  • 이상득;문태룡
    • 한국환경과학회지
    • /
    • 제15권10호
    • /
    • pp.919-928
    • /
    • 2006
  • The present study applied an atmospheric flow field model in Gwangyang-Bay which can predict local sea/land breezes formed in a complex terrain lot the development of a model that can predict short term concentration of air pollution. Estimated values from the conduct of the atmospheric flow field were used to evaluate and compare with observation data of the meteorological stations in Yeosu and the Yeosu airport, and the effect of micrometeorology of surround region by the coastal area reclamation was predicted by using the estimated values, Simulation results, a nighttime is appeared plainly land breezes of the Gwangyang-bay direction according to a mountain wind that formed in the Mt. of Baekwooun, Mt. of Youngchui. Land winds is formed clockwise circulation in the north, clockwise reverse direction in the south with Gangyang-bay as the center. Compared with model and observation value, Temperature is tend to appeared some highly simulation value in the night, observation value in the daytime in two sites all, but it is veil accorded generally, the pattern of one period can know very the similarity. And also, wind speed and wind direction is some appeared the error of observation value and calculation results in crossing time of the land wind and sea land, it can see that reproducibility is generally good, is very appeared the change land wind in the nighttime, the change of sea wind in the daytime. And also, according to change of the utilization coefficient of soil before and after development with Gwangyang-Bay area as the center. Temperature after development was high $0.55\sim0.67^{\circ}C$ in the 14 hoots, also was tend to appear lowly $0.10\sim0.22^{\circ}C$ in the 02 hours, the change of u, v component is comparatively tend to reduced sea wind and land wind, it is affected ascending air current and frictional power of the earth surface according to inequality heating of the generation of earth surface.

보온커튼을 설치한 플라스틱 온실의 틈새환기전열량 실측조사 (Experimental Study on the Infiltration Loss in Plastic Greenhouses Equipped with Thermal Curtains)

  • 남상운;신현호
    • 생물환경조절학회지
    • /
    • 제24권2호
    • /
    • pp.100-105
    • /
    • 2015
  • 온실의 난방부하 중 틈새환기전열부하 산정방법은 설계 기준마다 제각각이고, 온실의 규모에 따라 각각의 방법에는 큰 차이가 있으므로 보다 정확히 국내에 적용할 수 있는 방법을 정립할 필요가 있다. 본 연구에서는 원예시설의 환경설계 중 난방부하 산정방법 정립에 필요한 기초자료를 제공할 목적으로 다양한 종류의 보온커튼을 설치한 단동 및 연동 플라스틱 온실에서 추적가스법을 이용하여 틈새환기율을 실측하였으며, 온실의 틈새환기 전열부하 산정방법을 검토하였다. 연동온실의 틈새환기율은 $0.042{\sim}0.245h^{-1}$의 범위로 측정되었으며 단동온실의 틈새환기율은 $0.056{\sim}0.336h^{-1}$의 범위로 측정되어 단동온실이 약간 큰 것으로 나타났다. 온실의 틈새환기율은 단동, 연동 구분없이 보온커튼의 층수에 따라 크게 감소하는 것으로 나타났다. 또한 틈새환기율은 온실의 실내외 기온차가 커질수록 증가하는 경향을 보였으나, 실험기간 동안의 낮은 풍속 범위에서 외부 풍속에 따른 틈새환기율의 변화는 일정한 경향을 찾을 수 없었다. 온실의 난방설계를 위한 틈새환기율은 적정 실내외 기온차에서의 값을 제시할 필요가 있고, 최대난방부하 산정의 기준이 되는 낮은 풍속 범위에서 풍속에 따른 틈새환기율의 변화는 고려하지 않아도 되는 것으로 고찰되었다. 다만 강풍지역에서는 열관류율을 포함하여 최대난방부하를 약간 증가시키는 보정계수의 적용이 필요할 것으로 판단되었다. 온실의 틈새환기전열부하 산정방법을 검토한 결과 틈새환기전열계수와 온실의 피복면적을 이용하는 방법은 문제가 있는 것으로 나타났으며, 틈새환기율과 온실의 체적을 이용하는 방법이 합리적인 것으로 판단되었다.

새만금 간척지 첨단온실 에너지 설계를 위한 풍환경 및 온실 피복재의 영향 분석 (Analysis on Insulation of Wind Environment and Greenhouse Cover Materials Insulation for Advanced Greenhouse Energy Design in Saemangeum Reclaimed Land)

  • 서효재;서일환;노득하;이학성
    • 생물환경조절학회지
    • /
    • 제32권1호
    • /
    • pp.57-63
    • /
    • 2023
  • 본 연구에서는 새만금과 같은 간척지를 활용하여 대규모 첨단온실단지를 조성하는 경우 간척지의 환경적 특수성 중 높은 풍속에 따른 유리 단열재의 에너지 효율을 평가하였다. 현장에서 주로 사용되는 온실 단열재 중 4가지에 대한 평가 결과, 최대 37.4%의 에너지 차이를 보여, 온실 피복재의 선정이 중요함을 제시하였다. 이를 바탕으로 일반적인 내륙에서의 온실을 설계하는 것과 달리, 간척지에서는 내재해성 온실규격을 따라 시설을 설계하여야 하며, 에너지 소비량은 높아진 풍속과 재질을 고려하여 산정되어야 한다. 본 연구의 결과는 에너지 효율성을 온실 피복재의 종류와 풍속에 따라서 제시하고 있으며, 이는 대규모 첨단온실 조성 시 에너지 소비량을 예측하고, 이를 바탕으로 신재생에너지원을 포함하는 에너지 설계에 활용될 수 있다

타원관 열교환기를 적용한 팬코일 유닛의 운전 조건이 무차원 성능계수에 미치는 영향 (Effect of Operating Conditions of a Fan-Coil Unit with an Oval Tube Type Heat Exchanger on Non-Dimensional Performance Coefficient)

  • 윤재동;이영훈;성재용
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2019
  • In this study, the effect of operating conditions of fan-coil unit with an oval tube type heat exchanger on its non-dimensional performance coefficient has been investigated. Pressure drops and heat transfer rates were measured under heating condition for various water flow rates, inlet temperatures and wind speeds. As a non-dimensional performance coefficient, Colburn j-factor was evaluated. The results show that the most sensitive parameter on heat flux is the inlet temperature, which affects the heat flux 4.7 and 7.2 times more than the wind speed and water flow rate, respectively. On the other hand, the Colburn j-factor as a non-dimensionalized index decreases with the wind speed, and has an maximum when the wind speed is about 1 m/s. the Colburn j-factor increases slowly with the water flow rate and inlet temperature but at a certain range of inlet temperature, the opposite phenomenon is found.

TPO 시트재와 유도가열공법을 적용한 고내풍성 지붕마감 공법 (The Roofing System of High wind-Resistant Performance using Thermoplastic polyolefin and Electromagnetic Induction Technology)

  • 최희복;신윤석;최진철;이보형;강경인
    • 한국건축시공학회지
    • /
    • 제9권1호
    • /
    • pp.103-109
    • /
    • 2009
  • Strong winds according to global warming cause the increase of the frequency and the repair cost of damaged roofs. In the United States, Factory Mutual Insurance Company(FMIC) promotes the roofing design that resists heavy wind-load, as the means of strict criteria. This fact reveals that more durable roofing system will be also required in Korea. Therefore, this study aims at developing such a system with high wind-resistance performance using Thermoplastic polyolefin(TPO) and Electromagnetic induction technology(EIT) than the previous systems. The system presented in this study consists of 4 main devices as follow; 1) a disc to fix sheets for TPO & EIT method, which can conduct structural design according to site condition, such as region, building height, and wind load. 2) a nail to have about 30% stronger lifting-up capacity than that of the previous nail. 3) a disc to fix sheets, which has triangle protuberance not to damage sheets in the repeatable wind load, and 4) a electromagnetic induction device to combine a disc and a sheet by heating uniformly and quickly adhesive agent on the disc. The results of mock-up test illustrate that the system provides wind-resistant performance to achieve satisfactorily the structural design criteria of FMIC. In addition, the system is faster, chipper, and easier than the existing system, and is expected that this roofing system can be applied to the rehabilitations of an existing as well as a new building.

기상계측시스템을 위한 풍향.풍속모듈 및 DSP 센서 인터페이스시스템 설계 (The Design of a Wind Speed & Direction Module and a DSP Sensor Interface System for the Meteorological System)

  • 송도호;주재훈;옥기태;김상갑;최중경
    • 한국정보통신학회논문지
    • /
    • 제11권8호
    • /
    • pp.1478-1485
    • /
    • 2007
  • 본 논문에서는 풍향 풍속 계측모듈 및 DSP 센서인터페이스 회로 보드를 포함하는 기상계측 시스템을 제안한다. 이 DSP 시스템은 풍향풍속모듈, 대기압센서, 대기 온도 센서의 정보를 받아들이고, 빠르게 처리하여 PC 모니터링 시스템에 전달한다. 특히 풍향 풍속 모듈과 DSP 하드웨어는 직접 설계하여 적용한다. 풍향 풍속 모듈은 바람에 관한 벡터적 정보를 얻기 위해 4개의 박막형 RTD(Resistive Temperature Detectors) 저항센서를 히팅 코일에 의해 일정하게 가열된 원기둥 모양의 지지 표면에 벡터적으로 배치하는 구조를 채택한다. 이 구조를 채택한 계측 모듈은 진동, 습기, 부식 등에 강인하면서 정확한 계측을 가능케 한다. 센서 신호처리 회로는 TI사의 고속 DSP인 TMS320F2812 사용한다. 적용된 풍향 풍속 모듈을 통해 얻어진 데이터와 DSP 인터페이스 회로보드의 빠른 데이터 처리를 통해 저렴한 기상계측시스템을 구성 할 수 있었다.

하계 득량만의 연직성층해양의 시간적 변동 특성 (Temporal Variations of Stratification-Destratification in the Deukryang Bay, Korea)

  • 이병걸;조규대
    • 한국환경과학회지
    • /
    • 제4권2호
    • /
    • pp.139-150
    • /
    • 1995
  • 한국남해 연안에 위치한 득량만에 있어서 하계의 태양복사, 바람, 조류에 의한 해양의 연적성층 및 연적혼합현상의 시간적 변동특성을 밝히기 위한 연구를 수행하였따. 이를 위하여 27개 정점에서 관측된 수온, 염분, 밀도값을 분석하였고. Simpson과 Hunter(1974)가 제안한 위치에너지 개념을 도입한 에너지 방정식을 이용하여 태양복사, 바람, 조류에너지를 각각 계산하였다. 그 결과 하계 득량만 해양의 연직 성층 및 혼합현상은 태양복사에너지가 일정하다고 할때 바람보다는 조류에 의해 크게 좌우됨을 알 수 있었고, 조류에너지에 의한 수괴의 연직합에너지이여율 $epsilon$의 값은 약 0.010 ~ 0.014사이를 나타내고 있었다.

  • PDF