• 제목/요약/키워드: Wind Tunnel Experiment

검색결과 252건 처리시간 0.032초

대류방식을 이용한 열유속센서의 검정에 관한 연구 (A Study on Calibration of Heat Flux Sensor by using Convective Heat Transfer)

  • 양훈철;송철화;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1358-1363
    • /
    • 2004
  • The objective of this work is to propose calibration facility in which a thin film type heat flux sensor can be calibrated under convective flow condition by using a small wind tunnel with the constant temperature plate condition. A small wind tunnel has been built to produce a boundary layer shear flow above a constant temperature copper plate. 12-independent copper blocks, thin film heaters, insulators and temperature controllers were used to keep the temperature of flat plate constant at a specified temperature. Three commercial thin film-type heat flux sensors were tested. Convective calibrations of these gages were performed over the available heat flux range of $1.4{\sim}2.5kW/m^2$. The uncertainty in the heat flux measurements in the convective-type heat flux calibration facility was ${\pm}2.07%$. Non-dimensional sensitivity is proposed to compare the sensitivity calibrated by manufacturer and that of experiment conducted in this study.

  • PDF

풍동시험에서 사용하는 시험지지부의 동특성 해석용 툴에 관한 연구 (A Study on the Tool for Dynamic Analysis of the Test Support system using Wind Tunnel Testing)

  • 박태민;이기석;홍준희
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.370-376
    • /
    • 2005
  • This paper is described the program algorithm which can easily estimate dynamics of test support system by using mathematica tool based on the finite element method. We can determine the geometry, dimensions of the test support system, through tool stated in this paper for a certain test conditions. As a result of computer simulation and manufactured test support system's experiment in oder to verify suggested program, the dynamics of the test support system was well correspondent each other.

  • PDF

Characteristics, mathematical modeling and conditional simulation of cross-wind layer forces on square section high-rise buildings

  • Ailin, Zhang;Shi, Zhang;Xiaoda, Xu;Yi, Hui;Giuseppe, Piccardo
    • Wind and Structures
    • /
    • 제35권6호
    • /
    • pp.369-383
    • /
    • 2022
  • Wind tunnel experiment was carried out to study the cross-wind layer forces on a square cross-section building model using a synchronous multi-pressure sensing system. The stationarity of measured wind loadings are firstly examined, revealing the non-stationary feature of cross-wind forces. By converting the measured non-stationary wind forces into an energetically equivalent stationary process, the characteristics of local wind forces are studied, such as power spectrum density and spanwise coherence function. Mathematical models to describe properties of cross-wind forces at different layers are thus established. Then, a conditional simulation method, which is able to ex-tend pressure measurements starting from experimentally measured points, is proposed for the cross-wind loading. The method can reproduce the non-stationary cross-wind force by simulating a stationary process and the corresponding time varying amplitudes independently; in this way the non-stationary wind forces can finally be obtained by combining the two parts together. The feasibility and reliability of the proposed method is highlighted by an ex-ample of across wind loading simulation, based on the experimental results analyzed in the first part of the paper.

축소 모형실험을 통한 광센서 선형 화재 감지 시스템의 특성에 관한 연구 (A Study on the Characteristics of an Optical Sensor Linear Fire Detection System with Miniature Model Fire Experiment)

  • 김동은;김시국;이영신;이춘하;임우섭
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.19-26
    • /
    • 2016
  • 본 논문은 국내 주요 시설 및 국가 기반 시설로 변화되고 있는 터널 및 지하 공동구의 조기화재탐지설비시스템 설치에 이용되고 있는 광센서 선형 화재 감지 시스템에 대한 특성 분석을 목적으로 연구를 수행하였다. 연구 방법으로는 저온 환경인 $-20^{\circ}C$에서 5일간 5가지의 열감지기 중에서 작동 여부를 확인한 결과 광센서 선형 감지기만 작동하는 것을 알 수 있었다. 또한 터널과 같은 풍속이 발생되는 곳을 가정하여 축소 모형 터널을 제작하여 0 m/s와 1 m/s를 변수로 하여 광센서 선형 감지기의 작동 특성을 분석하였다. 그 결과로서 광센서 선형 감지 시스템의 온도 변화에 있어서는 풍속이 없을 때인 0 m/s 때의 값이 높게 나타나는 것을 알 수 있었다.

도로터널 제트팬 모형 실험 (The Jet-fan Model Test for a Road Tunnel Ventilation)

  • 류재홍;유용호;김진
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.630-640
    • /
    • 2003
  • As tunnel ventilation has recently been playing a major role in the tunnel construction and maintenance, longitudinal ventilation systems with jet fans have been utilized a great deal because they are economical and effective. However, due to the length of tunnels and heavy traffic, it is hard to take the field measurements. In this study, therefore, the computer simulation and the model experiment of producing a wind tunnel were carried out simultaneously and the results were compared. The ultimate objective of this research was to interpret the air flow pattern inside the tunnel with a jet-fan was set up, and to offer the useful data for jet-fan installation and operation. The experiment was carried out with varying the jet-fan diameters, location of installation, the discharge velocity. Result showed that as the initial static pressure came up with the negative pressure, the tunnel air flowed into the inside of tunnel from outside due to the entrainment-effect and the backflow-phenomenon by separation-effect was observed in the lower half part of the tunnel. As the jet-fan was getting closer to the tunnel wall, the entrainment-effect caused by the interaction with the wall was increased; however, the mixing distance and irregular flow section became longer, and also the air pressure loss generated by wall friction was large.

국내 P공항의 부지 제한조건을 고려한 로컬라이저의 최적위치 선정에 관한 연구 (A Study on Determination for Location of Localizer Antenna under Area Restrictive Conditions at Domestic P-Airport)

  • 조환기;김종범;송병흠
    • 한국항공운항학회지
    • /
    • 제23권2호
    • /
    • pp.7-14
    • /
    • 2015
  • This paper deals with an optimal determination process for the built-in location of localizer under restrictive siting area conditions of a domestic P-airport. Aerodynamic forces and moments acting on the localizer structure can be used a reference to find the safe distance from jet blast and the position at which the reasonable structural loading is applied. Wind tunnel experiment is conducted to measure aerodynamic loadings. The finite element analysis for structural deformation is employed to get the information of structural failure. A new localizer's position is determined by considering aerodynamic loading, structural strength and thermal loading due to jet blast. Deflector effect was also investigated in this study. In conclusion, the location of localizer can be placed at shorter than the current position and greatly decreased if the deflector is applied at the front of localizer.

풍동실험을 통한 수평축 풍력터빈 모델의 공력성능 연구 (Aerodynamic Performance for Horizontal Axis Wind Turbine Model using Subsonic Wind Tunnel)

  • 유기완;윤성준;이창수;최성옥
    • 한국항공우주학회지
    • /
    • 제35권11호
    • /
    • pp.964-972
    • /
    • 2007
  • 공기역학적으로 최대동력계수를 얻을 수 있도록 최적화된 블레이드를 장착한 수평축 풍력터빈 모델을 아음속 풍동에 장착하여 공력특성을 실험하였다. Upwind 방식과 downwind방식의 풍력 터빈 로터의 공력 특성을 비교하였을 때, 후자가 전자에 비해 측정토크의 교란이 더 크게 나타났으며, 이는 지지대에서 발생된 후류와 블레이드의 상호간섭이 원인으로 작용한다고 여겨진다. 블레이드 설치각이 0o인 경우에 설계 속도비 6에 해당하는 위치에서 최대 동력계수를 보여주고 있어 설계 조건을 잘 만족함을 알 수 있었다. 또한 음의 피치각 변화가 같은 값의 양의 피치각 변화에 비해 더 커다란 동력 감소가 발생되는 결과를 보여주었다.

CFD 모델을 이용한 체승 도시협곡의 흐름과 반응성 대기오염물질 확산 특성 연구 (A Study on the Characteristics of Flow and Reactive Pollutants' Dispersion in Step-up Street Canyons Using a CFD Model)

  • 김은령;박록진;이대근;김재진
    • 대기
    • /
    • 제25권3호
    • /
    • pp.473-482
    • /
    • 2015
  • In this study, street canyons with a higher downwind building (so called, step-up street canyons) are considered for understanding characteristics of flow and reactive pollutants' dispersion as a basic step to understand the characteristics in wider urban areas. This study used a CFD_NIMR_SNU coupled to a chemistry module just including simple $NO_X-O_3$ photochemical reactions. First, flow characteristics are analyzed in step-up street canyons with four aspect ratios (0.33, 0.47, 0.6, 0.73) defined as ratios of upwind building heights to downwind building height. The CFD_NIMR_SNU reproduced very well the main features (that is, vortices in the street canyons) which appeared in the wind-tunnel experiment. Wind speed within the street canyons became weak as the aspect ratio increased, because volume of flow incoming over the upwind building decreased. For each step-up street canyon, chemistry transport model was integrated up to 3600 s with the time step of 0.5 s. The distribution patterns of $NO_X$ and $O_3$ were largely dependent on the mean flow patterns, however, $NO_X$ and $O_3$ concentrations were partly affected by photochemical reactions. $O_3$ concentration near the upwind lower region of the street canyons was much lower than background concentration, because there was much reduction in $O_3$ concentration due to NO titration there. Total amount of $NO_X$ in the street canyons increased with the aspect ratio, resulting from the decrease of mean wind intensity.

Structural analysis and optimization of large cooling tower subjected to wind loads based on the iteration of pressure

  • Li, Gang;Cao, Wen-Bin
    • Structural Engineering and Mechanics
    • /
    • 제46권5호
    • /
    • pp.735-753
    • /
    • 2013
  • The wind load is always the dominant load of cooling tower due to its large size, complex geometry and thin-wall structure. At present, when computing the wind-induced response of the large-scale cooling tower, the wind pressure distribution is obtained based on code regulations, wind tunnel test or computational fluid dynamic (CFD) analysis, and then is imposed on the tower structure. However, such method fails to consider the change of the wind load with the deformation of cooling tower, which may result in error of the wind load. In this paper, the analysis of the large cooling tower based on the iterative method for wind pressure is studied, in which the advantages of CFD and finite element method (FEM) are combined in order to improve the accuracy. The comparative study of the results obtained from the code regulations and iterative method is conducted. The results show that with the increase of the mean wind speed, the difference between the methods becomes bigger. On the other hand, based on the design of experiment (DOE), an approximate model is built for the optimal design of the large-scale cooling tower by a two-level optimization strategy, which makes use of code-based design method and the proposed iterative method. The results of the numerical example demonstrate the feasibility and efficiency of the proposed method.

Wind-induced dynamic response and its load estimation for structural frames of circular flat roofs with long spans

  • Uematsu, Yasushi;Yamada, Motohiko
    • Wind and Structures
    • /
    • 제5권1호
    • /
    • pp.49-60
    • /
    • 2002
  • This paper describes a simple method for evaluating the design wind loads for the structural frames of circular flat roofs with long spans. The dynamic response of several roof models were numerically analyzed in the time domain as well as in the frequency domain by using wind pressure data obtained from a wind tunnel experiment. The instantaneous displacement and bending moment of the roof were computed, and the maximum load effects were evaluated. The results indicate that the wind-induced oscillation of the roof is generally dominated by the first mode and the gust effect factor approach can be applied to the evaluation of the maximum load effects. That is, the design wind load can be represented by the time-averaged wind pressure multiplied by the gust effect factor for the first mode. Based on the experimental results for the first modal force, an empirical formula for the gust effect factor is provided as a function of the geometric and structural parameters of the roof and the turbulence intensity of the approach flow. The equivalent design pressure coefficients, which reproduce the maximum load effects, are also discussed. A simplified model of the pressure coefficient distribution is presented.