• Title/Summary/Keyword: Wind Pressure Test

Search Result 316, Processing Time 0.026 seconds

An Experimental Study on the Effects of the Boundary Layer and Heat Transfer by Vortex Interactions ( I ) - On the common flow down - (와동간의 상호작용이 경계층 및 열전달에 미치는 영향에 관한 연구 ( I ) - Common flow down에 관하여 -)

  • Hong, Cheul-Hyun;Yang, Jang-Sik;Lee, Ki-Baik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.288-297
    • /
    • 2000
  • This paper describes the results of an experimental investigation of the flow characteristics and the heat transfer rate on a surface by interaction of a pair of vortices. The test facility consists of a boundary-layer wind tunnel with a vortex introduced into the flow by half-delta wings(vortex generators) protruding from the surface. In order to control the strength of the two longitudinal vortices, the angles of attack of the vortex generators are varied from 20 degree to 45 degree, but spacings between the vortex generators are fixed to 4 cm. The 3-dimensional mean velocity downstream of the vortex generators is measured by a five-hole pressure probe, and the hue-capturing method using the thermochromatic liquid crystals has been used to provide the local distribution of the heat transfer coefficient. By using the method mentioned above, the following conclusions are obtained from the present experiment. The boundary layer is thinned in the regions where the secondary flow is directed toward the wall and thickened where it is directed away from the wall. The peak augmentation of the local heat transfer coefficient occurs in the downwash region near the point of minimum boundary-layer thickness. Streamwise distributions of averaged Stanton number on the measurement planes show very similar trends for all the cases(${\beta}=20^{circ},\;30^{\circ}\;and\;45^{\circ}$).

An Experimental Study on the Effects of the Boundary Layer and Heat Transfer by Vortex Interactions ( II ) - On the common flow up - (와동간의 상호작용이 경계층 및 열전달에 미치는 영향에 관한 연구 ( II ) - Common flow up에 관하여 -)

  • Han, Dong-Joo;Yang, Jang-Sik;Lee, Ki-Baik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.298-305
    • /
    • 2000
  • The flow characteristics and the heat transfer rate on a surface by interaction of a pair of vortices were studied experimentally. The test facility consisted of a boundary-layer wind tunnel with a vortex introduced into the flow by half-delta wings protruding from the surface. In order to control the strength of the longitudinal vortices, the angles of attack of the vortex generators were varied from - 20 degree to - 45 degree, but spacings between the vortex generators were fixed to 4 cm. The 3-dimensional mean velocity measurements were made using a five-hole pressure probe. Heat transfer measurements were made using the thermochromatic liquid to provide the local distribution of the heat transfer coefficient. Unlike common flow down, common flow up vortices moved toward the centerline as they developed and interacted strongly with each other but not with the boundary layer. Spanwise profiles of Stanton number were similar for ${\beta}=-20^{\circ}\;and\;-35^{\circ}$, but not similar for ${\beta}=-45^{\circ}$. The case of ${\beta}=-20^{\circ}\;and\;-35^{\circ}$ showed the two peak Stanton number, but the case of ${\beta}=-45^{\circ}$ showed the only one peak Stanton number.

Residential Humidifying Element Made of Cellulose and PET Composite (셀룰로오스와 PET 복합체로 만들어진 가정용 가습소자)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.13-18
    • /
    • 2016
  • Humidifiers are used to control indoor humidity. Element-type humidifiers have the advantages of simple structure and low energy consumption, and Japanese products have been widely used for the humidifying elements. In this study, a new humidifying element made of cellulose and PET was developed, and the performance was compared with that of a Japanese element. The mass transfer rates and pressure drops were measured for an element installed at the entrance of a suction-type wind tunnel. The humidification efficiency of the new element was 2 to 4% greater and the pressure drop was 23 to 32% smaller compared to the Japanese element. The mass transfer effectiveness ($j_m/f$) of the new element is also 5 to 28% higher. However, the water absorption capacity was smaller than that of the Japanese element, meaning further development is needed.

Numerical Prediction of Acoustic Load Around a Hammerhead Launch Vehicle at Transonic Speed (해머헤드 발사체의 천음속 음향하중 수치해석)

  • Choi, Injeong;Lee, Soogab
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.1
    • /
    • pp.41-52
    • /
    • 2021
  • During atmospheric ascent of a launch vehicle, airborne acoustic loads act on the vehicle and its effect becomes pronounced at transonic speed. In the present study, acoustic loads acting on a hammerhead launch vehicle at a transonic speed have been analyzed using ��-ω SST based IDDES and the results including mean Cp, Cprms, and PSD are compared to available wind-tunnel test data. Mesh dependency of IDDES results has been investigated and it has been concluded that with an appropriate turbulence scale-resolving computational mesh, the characteristic flow features around a transonic hammerhead launch vehicle such as separated shear flow at fairing shoulder and its reattachment on rear body as well as large pressure fluctuation in the region of separated flow behind the boat-tail can be predicted with reasonable accuracy for engineering purposes.

A Model-Fitting Approach of External Force on Electric Pole Using Generalized Additive Model (일반화 가법 모형을 이용한 전주 외력 모델링)

  • Park, Chul Young;Shin, Chang Sun;Park, Myung Hye;Lee, Seung Bae;Park, Jang Woo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.11
    • /
    • pp.445-452
    • /
    • 2017
  • Electric pole is a supporting beam used for power transmission/distribution which accelerometer are used for measuring a external force. The meteorological condition has various effects on the external forces of electric pole. One of them is the elasticity change of the aerial wire. It is very important to perform modelling. The acceleration sensor is converted into a pitch and a roll angle. The meteorological condition has a high correlation between variables, and selecting significant explanatory variables for modeling may result in the problem of over-fitting. We constructed high deviance explained model considering multicollinearity using the Generalized Additive Model which is one of the machine learning methods. As a result of the Variation Inflation Factor Test, we selected and fitted the significant variable as temperature, precipitation, wind speed, wind direction, air pressure, dewpoint, hours of daylight and cloud cover. It was noted that the Hours of daylight, cloud cover and air pressure has high explained value in explonatory variable. The average coefficient of determination (R-Squared) of the Generalized Additive Model was 0.69. The constructed model can help to predict the influence on the external forces of electric pole, and contribute to the purpose of securing safety on utility pole.

Mountain Meteorology Data for Forest Disaster Prevention and Forest Management (산림재해 방지와 산림관리를 위한 산악기상정보)

  • Keunchang, Jang;Sunghyun, Min;Inhye, Kim;Junghwa, Chun;Myoungsoo, Won
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.4
    • /
    • pp.346-352
    • /
    • 2022
  • Mountain meteorology in South Korea that is covered mountains with complex terrain is important for understanding and managing the forest disaster and forest ecosystems. In particular, recent changes in dryness and/or rainfall intensity due to climate change may cause an increase in the possibility of forest disasters. Therefore, accurate monitoring of mountain meteorology is needed for efficient forest management. Korea Forest Service (KFS) is establishing the Automatic Mountain Meteorology Observation Stations (AMOS) in the mountain regions since 2012. 464 AMOSs are observing various meteorological variables such as air temperature, relative humidity, wind speed and direction, precipitation, soil temperature, and air pressure for every minute, which is conducted the quality control (QC) to retain data reliability. QC process includes the physical limit test, step test, internal consistency test, persistence test, climate range test, and median filter test. All of AMOS observations are open to use, which can be found from the Korean Mountain Meteorology Information System (KoMIS, http://mtweather.nifos.go.kr/) of the National Institute of Forest Science and the Public Data Portal (https://public.go.kr/). AMOS observations with guaranteed quality can be used in various forest fields including the public safety, forest recreation, forest leisure activities, etc., and can contribute to the advancement of forest science and technology. In this paper, a series of processes are introduced to collect and use the AMOS dataset in the mountain region in South Korea.

Cyclic behavior of RT-cement treated marine clay subjected to low and high loading frequencies

  • Al-Bared, Mohammed A.M.;Harahap, Indra S.H.;Marto, Aminaton;Mohamad, Hisham;Abad, Seyed Vahid Alavi Nezhad Khalil;Mustaffa, Zahiraniza
    • Geomechanics and Engineering
    • /
    • v.21 no.5
    • /
    • pp.433-445
    • /
    • 2020
  • The weakening and softening behavior of soft clay subjected to cyclic loading due to the build-up of excess pore water pressure is well-known. During the design stage of the foundation of highways and coastal high-rise buildings, it is important to study the mechanical behavior of marine soils under cyclic loading as they undergo greater settlement during cyclic loading than under static loading. Therefore, this research evaluates the cyclic stress-strain and shear strength of untreated and treated marine clay under the effects of wind, earthquake, and traffic loadings. A series of laboratory stress-controlled cyclic triaxial tests have been conducted on both untreated and treated marine clay using different effective confining pressures and a frequency of 0.5 and 1.0 Hz. In addition, treated samples were cured for 28 and 90 days and tested under a frequency of 2.0 Hz. The results revealed significant differences in the performance of treated marine clay samples than that of untreated samples under cyclic loading. The treated marine clay samples were able to stand up to 2000 loading cycles before failure, while untreated marine clay samples could not stand few loading cycles. The untreated marine clay displayed a higher permanent axial strain rate under cyclic loading than the treated clay due to the existence of new cementing compounds after the treatment with recycled tiles and low amount (2%) of cement. The effect of the effective confining pressure was found to be significant on untreated marine clay while its effect was not crucial for the treated samples cured for 90 days. Treated samples cured for 90 days performed better under cyclic loading than the ones cured for 28 days and this is due to the higher amount of cementitious compounds formed with time. The highest deformation was found at 0.5 Hz, which cannot be considered as a critical frequency since smaller frequencies were not used. Therefore, it is recommended to consider testing the treated marine clay using smaller frequencies than 0.5 Hz.

Development of Ocean Data Buoy and Real-Time Monitoring Technology (종합관측부이 개발 및 실시간 관측기술)

  • 심재설;이동영;박우선;박광순
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.11 no.1
    • /
    • pp.56-67
    • /
    • 1999
  • It is desired to use a domestically manufactured ocean data buoy for the long-term operational ocean monitoring. The ocean data buoy manufacturing technology was introduced through the research cooperation with the Qingkong University of Taiwan. The introduced ocean data buoy system was further expanded and improved for more efficient application for the marine environmental monitoring in Korea. The size of the ocean data buoy is 2.5 m in diameter, which is smaller compared to the NOAA's 3.0 m discus buoy to allow easy land transportation and ocean deployment as well. From the dynamic response test of the buoy carried out numerically, it was shown that the measurement of waves with period greater than 4 seconds is acceptable. The measurement and control system of the data buoy were improved to increase the number of measuring parameters, to reduce power consumption and to enhance better data analysis and management. Each component of the improved data buoy system was described in detail in this paper. Water quality sensors of water temperature, salinity, DO, pH and turbidity were added to the system in addition to the marine meteorological sensors of wind speed and direction, air temperature, humidity, air pressure and wave. Inmarsat satellite communication system is used for the real-time data telemetry from the buoy deployed offshore. A field performance test of the improved and domestically manufactured buoy was carried out for a month at the open sea off Pohang together with DatawelI's Wave-rider buoy to compare the wave data. The results of the test were satisfactory.

  • PDF

The Design and Structural Analysis of the APV Module Structure Using Topology Optimization (위상 최적설계를 이용한 APV Module Structure의 설계 및 구조해석)

  • Kang, Sang-Hoon;Kim, Jun-Su;Park, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.22-30
    • /
    • 2017
  • This paper presents the research results of a light weight through topology optimization and structural safety evaluation through structural analysis of a pressure system structure installed in an off-shore plant. Conducting a structure design according to the wind load and the dynamic load at sea in addition to a self-load and structure stability evaluation are very important for structures installed in off-shore plants. In this study, the wind and dynamic load conditions according to the DNV classification rule was applied to the analysis. The topology optimization method was applied to the structure to obtain a lightweight shape. Phase optimization analysis confirmed the stress concentration portion. Topology optimization analysis takes the shape by removing unnecessary elements in the design that have been designed to form a rib shape. Based on the analysis results about the light weight optimal shape, a safety evaluation through structural analysis and suitability of the shape was conducted. This study suggests a design and safety evaluation of an off-shore plant structure that is difficult for structural safety evaluations using an actual test.

Effects of Underexpanded Plume in Transonic Region on Longitudinal Stability (천음속 영역에서 과소 팽창 화염이 종안정성에 미치는 영향에 관한 연구)

  • Jung, Suk-Young;Yoon, Sung-Joon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.8
    • /
    • pp.118-128
    • /
    • 2004
  • Exhaust plume effects on longitudinal aerodynamics of missile were investigated by wind tunnel tests using a solid plume simulator and CFD analyses with both the solid plume and air jet plumes. Approximate plume boundary prediction technique was used to produce the outer shape of the solid plumer and chamber conditions and nozzle shapes of the air jet plumes were determined through plume modeling technique to compensate the difference in thermodynamic properties between air and real plume. From comparisons among turbulence models in case of external flow interaction with the air jet plume, Spalart-Allmaras model turned out to give accurate result and to be less grid-dependent. Effects induced by the plume were evaluated through the computations with Spalart-Allmaras turbulence model and the air jet plume to account for various ratios of chamber and ambient pressure and Reynolds number under the flight test condition.