• Title/Summary/Keyword: Wind Power Generation

Search Result 918, Processing Time 0.023 seconds

Acoustic Characteristics of Underwater Noise from Uldolmok Tidal Current Pilot Power Plant (울돌목 시험조류발전소의 수중소음 특성 연구)

  • Ko, Myungkwon;Choi, Jee Woong;Yi, Jin-Hak;Jeong, Weonmu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.8
    • /
    • pp.523-531
    • /
    • 2012
  • Recently, as a result of increasing concern about eco-friendly power, the demand for the power stations using environmentally friendly powers such as photovoltaic energy, wind force, tidal power, and tidal current has been increasing worldwide. Among these power stations tidal current power plant requires strong current generated by the topographic characteristics of the ocean floor. Uldolmok waterway producing very strong current is an ideal location for a tidal current power generation. However the occurrence of anthropogenic underwater noise generated by the tidal current power station may affect the marine environment. Therefore, it is necessary to evaluate the noise radiated from the station and predict the range influenced by the radiated noise. In this paper, the measurements of radiated noise spectrum level by the tidal current power station are presented, and the source level per unit area is estimated. Finally, the propagation properties of the radiated noise in the Uldolmok waterway is evaluated from the model simulation using the parabolic equation method, RAM.

Modified Empirical Formula of Dynamic Amplification Factor for Wind Turbine Installation Vessel (해상풍력발전기 설치선박의 수정 동적증폭계수 추정식)

  • Ma, Kuk-Yeol;Park, Joo-Shin;Lee, Dong-Hun;Seo, Jung-Kwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.846-855
    • /
    • 2021
  • Eco-friendly and renewable energy sources are actively being researched in recent times, and of shore wind power generation requires advanced design technologies in terms of increasing the capacities of wind turbines and enlarging wind turbine installation vessels (WTIVs). The WTIV ensures that the hull is situated at a height that is not affected by waves. The most important part of the WTIV is the leg structure, which must respond dynamically according to the wave, current, and wind loads. In particular, the wave load is composed of irregular waves, and it is important to know the exact dynamic response. The dynamic response analysis uses a single degree of freedom (SDOF) method, which is a simplified approach, but it is limited owing to the consideration of random waves. Therefore, in industrial practice, the time-domain analysis of random waves is based on the multi degree of freedom (MDOF) method. Although the MDOF method provides high-precision results, its data convergence is sensitive and difficult to apply owing to design complexity. Therefore, a dynamic amplification factor (DAF) estimation formula is developed in this study to express the dynamic response characteristics of random waves through time-domain analysis based on different variables. It is confirmed that the calculation time can be shortened and accuracy enhanced compared to existing MDOF methods. The developed formula will be used in the initial design of WTIVs and similar structures.

Investigating the Power-Performance Prediction on an H- and Helical-type Tidal Current Turbine Using CFD Method (CFD에 의한 H 및 Helical 타입 조류발전용 터빈의 출력성능예측에 관한 연구)

  • Kim, Bum Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.8
    • /
    • pp.653-660
    • /
    • 2015
  • In this study, we conduct power performance and load analyses of two different types of vertical-axis tidal-current turbines using the computational fluid dynamics (CFD) method. To analyze the power output and loads, we perform transient CFD simulations considering the cavitation model using ANSYS CFX. The averaged power output of an H-type rotor was 7.47 kW and 67.6 kW in normal and extreme operating conditions, respectively, which did not satisfy the initial design conditions. However, in the case of the helical-type rotor, the power output under normal and extreme conditions were close to the expected values. The cavitation, which may cause instantaneous power fluctuation, occurred repeatedly at the suction side of the rotors. In order to guarantee a more stable power supply and to prevent fatigue failure, we require a design that minimizes cavitation.

Hydrogen Production by Gasification Technologies (가스화기술을 이용한 수소제조 기술)

  • 윤용승
    • Journal of Energy Engineering
    • /
    • v.13 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Gasification is the essential technology that can meet the interim hydrogen demand of large quantity before entering the hydrogen economy. Although the hydrogen production that is based upon the pure renewable energy like wind and solar power will eventually prevail, the interim mass production of hydrogen for the next ten to twenty years will come from the technologies that can demonstrate the economic feasibility in production cost with a high potential in minimizing CO$_2$ generation and in improving plant efficiency. Particularly, feedstock such as natural gas, coal, petroleum residual oil, wastes, and biomass appears to be utilized in Korea as hydrogen source, at least during the short and medium period of time, owing to the advantage in production cost. Because one of the main reasons behind the recent hydrogen issue is the reduction requirement of CO$_2$ that would be controlled according to the climate change protocol, hydrogen production technologies must be developed to yield the minimal CO$_2$ generation.

Analysis of the behavior of gray rockfish (Sebastes schlegelii Hilgendorf) on the construction of wind power generators in the sea area around Byeonsan Peninsula, Korea (변산반도 주변해역에서 풍력발전기 건설공사에 대한 조피볼락(Sebastes schlegelii Hilgendorf )의 행동분석)

  • HEO, Gyeom;HWANG, Doo-Jin;MIN, Eun-Bi;OH, Sung-Yong;PARK, Jin Woo;SHIN, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.55 no.2
    • /
    • pp.129-137
    • /
    • 2019
  • This study was conducted to investigate the effects of underwater noise caused by pile driving during marine construction on fish. In this study, the three gray rockfish were released about 1 km away from the construction site of wind power generation on July 18, 2018 and traced using two acoustic telemetry techniques. The behavior of the fish was analyzed by calculating the moving distance, swimming speed and direction of the gray rockfish. In the results of the acoustic tracking using the ship, the rockfish moved about 2.11 km for about two hours at a speed of $0.28{\pm}0.14m/s$ (0.94 TL/s). The bottom depth of the trajectory of the rockfish was $1.0{\pm}0.6m$ on average. There was a significant directionality in swimming direction of the gray rockfish, and there was no significant correlation between the swimming direction and tidal current direction. Moving distance during 5 minutes (5MD) during pile driving and finishing operations between rock surface and bedrock were 0.94-0.96 times (76.0-77.0 m) and 1.81-2.73 times (146.0-219.5 m), respectively, compared with no pile driving. This study is expected to be used as a basic data of fish behavior research on underwater noise.

A study on the development of distribution simulator and simulation results for use in distribution automation system of IEC 61850 protocol (IEC 61850 프로토콜의 배전자동화시스템에 사용을 위한 배전시뮬레이터 개발과 시뮬레이션 결과에 관한 연구)

  • Kim, Jae-Hong;Oh, Jae-Gon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.95-102
    • /
    • 2022
  • It is a study for the evaluation of the stability of the distribution automation system for the expansion of renewable energy. Through the Renewable Energy 3020 Implementation Plan, the government plans to expand new renewable energy and convert it to participatory energy that improves the quality of life of the people by 2030. The government has set a target of 20% of domestic supply energy for renewable energy generation by 2030. It is planning to establish more than 95 percent of its new facilities with clean energy such as solar power and wind power. By expanding the supply of renewable energy, new energy businesses and distributed power industry were fostered, and short-distance, low-voltage, and small-scale power generation were rapidly expanded rather than large-scale power development in the past. Due to this demand, the importance of power distribution facility operation has emerged and the need for distribution automation system is increasing. This paper discusses the development of a power distribution simulator for the performance and function evaluation of power distribution automation systems and presents the results of an interlocking test with the power distribution automation system. In order to introduce an advanced system into the power distribution system, it is necessary to take advantage of the transmission and distribution system. The DNP3.0 protocol is used in the distribution system and the IEC61850 protocol is used in the transmission and distribution system. It was concluded that the functions and performance of operations were satisfied when these two protocols are mixed and used in the distribution automation system.

Development of Programs to Analyze Mechanical Load Data of Wind Turbine Generator Systems and Case Studies on Simulation Data (풍력발전시스템의 기계적 하중 데이터 분석 프로그램 개발과 시뮬레이션 데이터 적용 사례)

  • Bang, Je-Sung;Han, Jeong-Woo;Gil, Kyehwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.789-798
    • /
    • 2013
  • The procedures and relevant programs developed for analyzing mechanical load data of wind turbine generator systems, which are obtained through type certification tests, are verified. The following issues according to IEC 61400-13 are covered in the developed programs: data validation, time series analysis, summary load statistics, generation of fatigue load spectra, and estimation of equivalent loads. A capture matrix for normal power production is generated to determine whether the collected data sets are sufficient to carry out fatigue analysis. Fatigue load spectra are obtained through the rainflow counting method using 50 load ranges; finally, equivalent loads are calculated using different S-N curve slopes, m, according to the relevant materials. Case studies are performed using aero-elastic simulation data of the NREL 5 MW baseline wind turbine with a monopile foundation.

Convergence system of offshore wind infrastructure monitoring using the RC submarine (RC잠수함을 이용한 해상풍력하부구조 모니터링 융합시스템)

  • Bang, Gul-Won;Bang, Sang-Won;Kim, Yong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.6
    • /
    • pp.177-183
    • /
    • 2015
  • The image information acquired by a model submarine is transmitted through the repeater. The control signal of a position for submarine and its speed is also controlled by the repeater. Shooting images of underwater circumstances are transmitted to the repeater where the received signal controls a position and speed of underwater submarine. This repeater is combined by a buoy that is floating on the surface to relay the signal of image as well as control between a control unit and a submarine whereas the repeater communicates wirelessly with a control unit. Due to wire communication between the repeater and the submarine, the underwater exploration can be smoothly carried out without a risk of loss of a model submarine. Also, connecting to the repeater and control unit wirelessly makes it possible to conduct easily the underwater exploration. The convergence technology that combines a wireless communication and a control as well as a model submarine is designed.

An Optimum Power Rating Selection of a Photovoltaic-Wind Hybrid Generation System Utilizing Least Square Method (최소 자승법을 이용한 태양광.풍력 복합 발전 시스템의 최적 용량 선정)

  • Kim, Si-Kyung;Yu, Gwon-Jong;Song, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.379-381
    • /
    • 1996
  • 본 논문에서는 그리드 독립형 태양광 풍력 복합 발전 시스템에 대한 최적의 태양광 어레이 사이즈 및 풍력 발전 시스템을 결정하는 방법을 제안하였다. 연구에 사용되어진 풍력 및 태양광 일사량에 대한 데이터는 제주도 지역에서 1년간 실측되어진 데이터를 기준으로 하였으며, 이러한 실측되어진 데이터는 풍속 및 태양광의 확률 밀도 함수(Probability Density Function)를 결정하는데 사용되어 졌다. 풍속 및 태양광 일사량의 확률 밀도 함수와 태양광 어레이 및 풍력 발전기의 여러 파라미터는 복합 발전 시스템의 평균 발생 전력을 계산하는데 사용하였고, 도서지역에서 1년간 계측되어진 부하의 변동에 대하여 최적의 태양광 어레이, 풍력 발전 용량을 선정 하기 위하여 최적 자승의 법칙이 사용되었다.

  • PDF

A Study of Solar Thermal power Generation (태양열 발전시스템 보급현황 연구)

  • Cho, Hui-Chang;Kim, Kern-Joong;Hwang, In-Jun;Yang, Min-Uk;Park, Jeong-Jin;Lee, Jae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.273-275
    • /
    • 2008
  • In Korea, over 97% of local energy demand is imported from other countries. And we have to lift the energy independence level up to 5% with replacement energy(renewable energy) such as solar, wind..etc. by 2011 according to the energy agreement made in Kyoto Protocol. So, we proposed some opinions such as the better improvement of solar thermal industry the people' view, cooperation among industry/university/research institutes, remote control/maintenance and government's legislature and supporting system etc.

  • PDF