• Title/Summary/Keyword: Wind Power Energy

Search Result 1,564, Processing Time 0.035 seconds

Reassessment of Economic Feasibility for a Wind Farm on Jeju Island Considering Variable Jeju SMP (변동 제주 SMP를 적용한 제주도 육상풍력단지의 경제성 재평가)

  • Kim, Hyo-Jeong;Ko, Kyung-Nam;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.41-50
    • /
    • 2013
  • Economic feasibility study using weighted average variable Jeju System Marginal Price, SMP, was conducted for Gasiri wind farm of Jeju Island. To predict the variable Jeju SMP, generator share ratio for SMP was calculated from the real time wind power production and the power demand data for years. Also, sensitivity analysis on Net Present Value, NPV, and Benefit/Cost Ratio, B/C ratio, were performed to clarify which factors are more important in assessing economic feasibility. The result shows that the Gasiri wind farm has a minimum of 110 billion won and a maximum of 132 billion won difference between fixed and variable SMP. Also, Capacity Factor, C.F., had the highest sensitivity for NPV, followed by SMP. Accordingly, when economic analysis for a potential wind farm site is carried out, the variable SMP as well as C.F. should be considered for more accurate assessment of the wind farm.

Study of Power System Impact Assessment Standard for Large-scale Wind Farms (풍력발전 계통연계 평가기준 연구)

  • Choy, Young-Do;Jeon, Young-Soo;Park, Young-Shin;Jeon, Dong-Hoon;Yoon, Ki-Kab;Park, Sang-Ho;Shin, Jung-Hoon;Lee, Jae-Gul
    • New & Renewable Energy
    • /
    • v.6 no.1
    • /
    • pp.12-19
    • /
    • 2010
  • In Korea, experiences in wind farm operation are limited and the foundation for setting standards in electrical system connection is still weak in comparison to the operation experience in connection of wind power to the electrical system of other countries around the world. Therefore, standards that are being applied in various countries for connection and optimal operation in wind farms need to be examined, and in addition, procedures for the assessment of the effects on the system are needed for setting connection standards and optimal operation plans in accordance with Korean electrical system characteristics. In this study, procedures for the assessment of effects of wind power connection to the electrical system are presented.

Characteristics for Sound Power of Wind Turbine Gearbox by Load Variation (부하변동에 따른 풍력발전기용 증속기의 음향파워 특성)

  • Lee, Jae-Jeong;Lee, Seung-Yong;Seo, Young-Wook;Lee, Jin-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.311-315
    • /
    • 2012
  • In these days, promising renewable energy, wind turbine is clean energy but has an environmental pollutant which is noise. Noise assessment is one of the major performance evaluations for wind turbine and nowadays, developing and research for measurement and method of the assessment considering environmental pollutants is being important. Object in this study is that figuring out sound power characteristic of the gearbox for wind turbine through measuring sound intensity. In back-to-back test, we can figure out the noise characteristic of the gearbox for wind turbine through comparing and measuring sound pressure level, sound power level in operating at the each load condition respectively.

  • PDF

Nonlinear Structure-Soil Interaction Analysis for the Suction Bucket Foundation of Offshore Wind-Turbine (해상풍력 석션버켓 기초 구조-지반 상호작용 비선형 구조해석 및 실험결과 비교)

  • Jin, Jeongin;Kim, Donghyun;Jung, Minuk
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.469-475
    • /
    • 2016
  • As we are facing the shortage of oil energy, studies on renewable energy, wind energy research has been naturally getting attention. Among wind energies, ocean wind energy is relatively abundant compared to land wind energy and therefore, is getting much attention in terms of its efficiency. However, the problem is the cost. Generally, the cost ratio of the supporting structure is over 25% of the total installation cost of a offshore wind turbine system. Thus, it is very important to reduce the total installation cost of the offshore wind turbine and develop accurate analysis methodology for various offshore wind turbine foundations. In this study, nonlinear structure-soil interaction analyses have been proposed and conducted for the typical suction bucket model of an offshore wind turbine foundation, and the results were compared with experimental test data for numerical validations.

A Study of the Analysis System of Remote Control a Voltage Fluctuation of a Based Wind Turbine (풍력기반 하이브레드 풍력발전기의 원격 정전압 변동률 분석 장치에 관한 연구)

  • Jang, Mi-Hye;Sun, Mean-Young;Lee, Jong-Jo;Lim, Jae-Kyoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.456-459
    • /
    • 2009
  • we studied a data acquisition and control system of a wind turbine for measuring and controlling a voltage fluctuations of a wind turbine system. The wind turbine system is installed out control area. So, it is so important for supervising to wind turbine of a maintenance, wind speed, optical resources wind turbine output, wind speed, wind direction, over voltage of a generator. This system can be supplied a data of over voltage, under voltage, voltage fluctuations of a wind turbine for controlling an EMS : Energy Management System or a SCADA : Supervision Control and Data Acquisition at a constitute of a wind farm. The of voltage fluctuation system of a wind turbine is improving an electric power supply power quality of a distribution line and unspecified individuals of used wind turbine.

  • PDF

Computational Flow Analysis on Applicability of Vehicle-Induced Wind to Highway to Wind Power Generation (차량 유도풍 풍력발전 활용 가능성의 전산유동해석)

  • Kim, Hyun-Goo;Woo, Sang-Woo;Jang, Moon-Seok;Shin, Hyung-Ki
    • New & Renewable Energy
    • /
    • v.4 no.4
    • /
    • pp.30-36
    • /
    • 2008
  • The possibility of whether the induced wind from a vehicle traveling on highway can be used in wind power generation has been verified through computational flow analysis. The bus which is presumed to accompany relatively strong and wide range of induced wind compared to passenger vehicles because of its wide frontal area has been set as the subject of research. In order to ensure the reliability of research, the flow analysis surrounding the bus on a flat road where median strip is not installed has been compared with a preceding research while the validity of grid system and interpretation method used in this research have been assured by a qualitative method. In case of the median strip type wind power generator system, because it has been verified that a strong streamwise wind speed (5 m/s) is derived from the contraction effect of flow passage between the bus and the median strip while maintaining a relatively consistent upwind wind speed (1.4 m/s) in vertical direction in the wake area after the bus passes by although the change of wind speed is intense, it was decided as having some possibility of wind power generation. In case of the traffic sign panel type wind power generator system installed at the upper top of highway, because the wind speed of 2 m/s level has been derived for a limited time only at a section equal to the length of the bus and a faint induced wind speed less than 0.5 m/s was shown at other regions, it was decided as having almost no possibility of wind power generation.

  • PDF

Numerical study on the characteristics of TKE in coastal area for offshore wind power (해상풍력발전을 위한 연안지역의 난류에너지 특성 수치연구)

  • Yoo, Jung-Woo;Lee, Soon-Hwan;Lee, Hwa-Woon
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1551-1562
    • /
    • 2014
  • To clarify the characteristics of TKE (Turbulence Kinetic Energy) variation for offshore wind power development, several numerical experiments using WRF were carried out in three different coastal area of the Korean Peninsula. Buoyancy, mechanical and shear production term of the TKE budget are fundamental elements in the production or dissipation of turbulence. Turbulent kinetic energy of the south coast region was higher than in other sea areas due to the higher sea surface temperature and strong wind speed. In south coast region, strong wind passing through the Korea Strait is caused by channelling effect of the terrain of the Geoje Island. Although wind speed is weak in east coast, because of large difference in wind speed between the upper and lower layer, the development of mechanical turbulence tend to be predominant. Since lower sea surface temperature and smaller wind shear were detected in west coastal region, the possibility of turbulence production not so great in comparison with other regions. The understanding of the characteristics of turbulence in three different coastal region can be reduced the uncertainty of offshore wind construction.

A Methodology for Reliability and Economic Analysis of Wind Energy Embedded Electric Power System (풍력을 포함하는 전력 시스템의 신뢰성과 경제성 해석 방법)

  • Jain, Amit;Min, Joon-Ki;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1316-1318
    • /
    • 2002
  • A methodology for reliability and economic analysis of wind embedded electric power system is presented in this paper. This is done by evaluating the reliability index, loss of load expectation (LOLE), for the power system with and without integration of wind system in the overall electric power system. Economic analysis of the wind energy embedded electric system is done in terms of conventional fuel saving assessment due to the use of wind power generation units.

  • PDF

A Study on Stable Operating for Buan S/S Byunsan D/L (2728 02) Power Distribution Area Connected with Wind Power Generator (부안 S/S 변산 D/L(2728 02) 공급구역을 대상으로 한 풍력발전시스템 계통연계 시 보호협조 방안)

  • Jang, Mi-Hye;Shin, Baek-Sik;Song, Weon-Jin;Kim, Yeong-Min;Kim, Dong-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.508-509
    • /
    • 2008
  • A creation of large and small scale wind farm was considered to proper already, as according to real Jeonbuk Saemangeum project. A grow larger to be construction of the new and renewable energy thema park as well as creation possibility of large scale wind farm afterward. Therefore, in this paper was proposed a counterplan on D/L protection cooperation of Buan S/S Byunsan D/L (2728 02) power distribution line in case of connected with wind power generator.

  • PDF

Analysis on the Operation Characteristic of the Combined Electric Power Generation System by Photovoltaic and Wind Energy with Power Storage Apparatu (동력저장장치를 이용한 풍력$\cdot$태양광 복합발전시스템의 특성분석)

  • Lim Jung-Yeol;Lee Jung-Il;Jung Hak-Su;Cha In-Su
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.58-62
    • /
    • 2001
  • Photovoltaic and wind power generation have an advantage of unlimited and unpolluted amount of energy resource. In conventional wind generation systems, since the blade rotates at low speed when the velocity of wind decreases their operations are possible only under limited conditions. Therefore they are in trouble of self-generation without the help of auxiliary generation devices outside. The system driven by the wind force in this paper consists of a generator, an invertor, batteries and sets for power storage with a spring. In this paper, the operation characteristics of system were analyzed through experiments for a trial product.

  • PDF