• Title/Summary/Keyword: Wind & Fire

Search Result 360, Processing Time 0.026 seconds

Literature Review on syndrome differentiation and herbal medicine of Migraine - focusing on chinese journals - (편두통 변증과 처방에 관한 문헌적 고찰 - 중국 논문 중심으로 -)

  • Sun, Seung-Ho;Ko, Ho-yoen
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.11 no.1
    • /
    • pp.61-69
    • /
    • 2010
  • Objective : To investigate the syndrome differentiation's types and herbal medicine of migraine through Chinese journals review Methods : Journal search was performed using the searching engine of China Academic Journal(CAJ) in China National Knowledge Infrastructure(CNKI) from January 2000 to November 2010. Searching key words were "migraine", "chinese traditional medicine" and "syndrome differentiation". We included all kinds type of journals that explained or referred definite syndrome differentiations. The methods of treatment and Herbal medications by syndrome differentiation in contents of finally selected journals were extracted and summarized. Results : Eighteen chinese journals were selected finally. Fifteen kinds of syndrome differentiations about migraine were investigated, which included blood stasis due to qi stagnation (氣滯血瘀) quoted 15 times, middle obstruction of phlegm-dampness (痰濕中阻) 11 times, liver yang transforming into wind (肝陽化風) 10 times, deficiency of qi and blood (氣血虧虛) 6 times, wind-cold invading 風寒侵襲 淸陽鬱遏 4 times, cold invading reverting yin (寒犯厥阴) 4 times, liver-kidney deficiency (肝腎虧虛) 3 times, liver qi depression and qi stagnation (肝鬱氣滯) 2 times, liver depression transforming into fires (肝鬱化火) 2 times, wind-fire of liver-gallbladder (肝膽風火) 3 times, intense stomach fire and heat (胃火熱盛) 2 times, insufficiency of blood deficiency (血虛不榮) 2 times, insufficiency of qi deficiency (氣虛不充) 2 times, insufficiency of kidney qi and sea of marrow deficiency (腎氣不足, 髓海空虛) 2 times, and qi depression due to wind invading (風邪侵襲, 氣鬱不宣) 2 times. Conclusion : We suggests the first choice of oriental treatment for migraine can be considered among syndrome differentiation's types of blood stasis due to qi stagnation, middle obstruction of phlegm-dampness, liver yang transforming into wind, deficiency of qi and blood, and cold invading reverting yin. further systematic study will be needed.

  • PDF

An Experimental Study on the Effect of Longitudinal Ventilation on the Variation of Burning Rate in Tunnel Fires (터널 화재시 종류식 환기가 연소율 변화에 미치는 영향에 관한 실험적 연구)

  • Yang Seung Shin;Kim Sung Chan;Ryou Hong Sun
    • Tunnel and Underground Space
    • /
    • v.15 no.1 s.54
    • /
    • pp.55-60
    • /
    • 2005
  • In this study, the 1/20 reduced-scale experiments using Froude scaling were conducted to investigate the effect of longitudinal ventilation on the variation of burning rate in tunnel fires. The methanol square pool fires with heat release rate ranging from 3.57 kW to 10.95 kW were used. The burning rate of fuel was obtained by measured mass using load cell and temperature distribution were measured by K-type theomocouples in order to investigate smoke movement. The wind tunnel was connected with one side of the tested tunnel, and logitudinal ventilation velocity in the tested tunnel was controlled by power of the wind tunnel. In methanol fire case, the increase in ventilation velocity decreased the turning rate due to the direct cooling of fire plume. For the same dimensionless velocity(V), homing rate decreased as the size of pool fire increased.

A Study on causes and remedies of hearing disturbance in chinese medical journals (難聽의 原因, 症狀, 治法에 對한 硏究;中醫雜誌를 中心으로)

  • Kim, Seong-Bae;Kim, Jong-Han;Lim, Gyu-Sang
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.7 no.1
    • /
    • pp.35-51
    • /
    • 1994
  • This is the study on causes and remedies of hearing disturbance in chinese medical journals(1991-1993). The results were as follows. 1. The causes of sudden deafness(突發性耳聾) were usually fire in the liver(肝火).phlegmatic fire(痰火), deficiency of the vital function and essence of the kidney(腎虛), blood stasis or sludge due to stagnation of vital energy stagnation(氣滯血瘀). Remove endogenous heat or fire method(淸瀉火熱法). circulation of phlegm and dampness(運化痰濕). using tonics to cure disease due to deficiency of vital essence of both the liver and the kidney(滋補肝腎) were used for each treatment. 2.The causes of menieres disease were usually mental disturbance due to phlegmatit fire(痰化上搖). dampness-phlegm long standing(痰濕內停), water-dampness retention(水濕停滯), Method of remove heat and circulation phlegm(淸熱化痰法), method of remove water and dampness(利水渗濕法), invigorate function of the spleen and circulation of dampness method(健脾化濕法) were used for each treatment. 3. The causes of toxico-deafness(中毒性 耳聾) were usually heart, liver and kidney functional weakness(心肝腎虛), vital essence and blood weakness(氣血虛弱). Remove obstruction in the flow and circulation phlegm(通窮化痰), reinforce vital energy and tonify blood (補氣活血), using tonics to cure disease due to deficiency of vital essence of both the liver and the kidney(滋補肝腎) were used for each treatment. 4. The causes of deafness (耳聾), tinitus(耳鳴) were usually mental disturbance due to wind and heat(風熱上搖). flaming up of excessive heat of the liver(肝火上亢). exhaustion seat of reproductive essence in kidney(腎精虧虛). Remove endogenous heat and disperse wind(淸熱疏風). remove the fire of liver(淸肝瀉火), through nourish kidney check exuberance of yang(滋腎潛陽), nourish kidney yang(補腎陽). replenish vital energy and improve essential substance(益精血), blood activate for treatment of blood stasis(活血化瘀) were used for each treatment. 5. The effects of mainly used drugs were classified into method of water and dampness remove medicine(利水渗濕藥), nourishing liver and kidney medicine(補肝腎藥), improve blood and vital energy activate medicine(活血行氣藥), through nourish yan medicine check exuberance of yang(滋陰潛陽藥).

  • PDF

Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System (특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구)

  • Lee, Su-Kyung;Hong, Dae-Hwa
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.85-90
    • /
    • 2011
  • This study of the vestibule of pressurizing smoke control system installed in domestic high-rise buildings for evacuation in case of fire, when the door is open to forming characteristics of the air flow was analyzed using fire dynamics simulator and analyzed of variance. Vestibule which is compartment of the design condition, air flow in the exhaust damper was formed severe turbulence confirming preceding research. The door position is in the range of formed vortex, unsteady flow of air occurs at the point that the door could be confirmed. According to the NFSC 501A, door to symmetrically separate the average of 10 points or more as measured from the average of wind speed to do is based. Under these conditions, it is difficult to measure the characteristics of the upper air flow of upper points. so measuring points are subdivided by more than 64 points method presented in TAB because severe deviation of wind speed.

A Study on the Correlation between Forest Fire Occurrence and Asian Dust during the Spring Season from 2000 to 2008 (2000~2008년 봄철 황사와 산불발생의 관계 분석)

  • Won, Myoung-Soo;Yoon, Suk-Hee;Lee, Woo-Kyun
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.3
    • /
    • pp.148-156
    • /
    • 2011
  • The purpose of this study is to analyze the patterns of forest fire possibly related with Asian dust event and carry out a correlation analysis between forest fire occurrence and existence or not of the Asian dust event during dry seasons i.e. February to May in 2000 to 2008. To study the correlation of forest fire and Asian dust, we surveyed information of Asian dust observations, forest fire statistics, fire danger rating index, weather data such as temperature, relative humidity and wind speed of the day occurring the forest fire. As a consequence of analysis, the regional frequency of Asian dust was the highest in Gyeonggi and Chungbuk divisions. Frequencies of forest fire occurrence by the Asian dust events were the highest in the day before three days of the Asian dust event. The highest frequent regions of forest fire occurrence were district of boundary line between Gyeonggi and Western of Gangwon, Chungbuk and Gyeonbuk inland. The correlation between forest fire and fire danger rating index showed the high correlation with the day before three days and after three days of the Asian dust event. These correlation coefficients were 0.50038 and 0.53978 to 1% significance level. The result of analysis between the frequency of forest fire occurrence and wind speed had a highly negative relationship at all the Asian dust days, the day before and after three days. The correlation coefficients had been -0.58623 to -0.61245 to 1% significance level. Relative humidity showed a little of negative relationship with forest fire occurrence in -0.2568(p ${\leq}$ 0.01) for the Asian dust day and -0.35309(p ${\leq}$ 0.01) for next three days. Moreover, at the day before three days of Asian dust events, it was -0.23701 to 1% significance level. However, the mean temperature did not correlate with frequency of forest fire occurrence by Asian dust events at all.

Development of Large Fire Judgement Model Using Logistic Regression Equation (로지스틱 회귀식을 이용한 대형산불판정 모형 개발)

  • Lee, Byungdoo;Kim, Kyongha
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.3
    • /
    • pp.415-419
    • /
    • 2013
  • To mitigate forest fire damage, it is needed to concentrate suppression resources on the fire having a high probability to become large in the initial stage. The objective of this study is to develop the large fire judgement model which can estimate large fire possibility index between the fire size and the related factors such as weather, terrain, and fuel. The results of logistic regression equation indicated that temperature, wind speed, continuous drought days, slope variance, forest area were related to the large fire possibility positively but elevation has negative relationship. This model may help decision-making about size of suppression resources, local residents evacuation and suppression priority.

Characteristic Analysis of Forest Fire Burned Area using GIS (GIS를 이용한 산불피해지역 특성분석)

  • Lee, Si-Young;Kang, Yong-Seok;An, Sang-Hyun;Oh, Jeong-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.5 no.1
    • /
    • pp.20-26
    • /
    • 2002
  • The forest fire occurrences and burned area are increasing every year since 1990 in Korea, of which 65% is covered by forest. This study attempts to analyze topographic characteristics of forest fire burned area using GIS, and we also applied the statistical analysis based on the fire characteristics such as weather, forest as fuels and topography in small and large forest fire burned areas. The result of the statistical analysis shows that the size of forest fire was related to the slope length, slope degree, wind speed, forest type, and forest continuity.

  • PDF

A Fire Prevention System of the Nacelle of Wind Turbine Generator System Based on Broadband Powerline Communication (광대역 전력선통신 기반 풍력발전기 너셀 내부 화재예방시스템)

  • Kim, Hyun-Sik;Ju, Woo-Jin;Kang, Seog Geun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1229-1234
    • /
    • 2018
  • In this paper, a fire prevention system based on a broadband powerline communication (PLC) system is implemented and a demonstration experiment is carried out to prevent from or promptly dealing with possible fires within the nacelle of a wind turbine generator system (WTGS). For this purpose, an inductive coupler having satisfactory attenuation characteristic in the frequency region for high-speed PLC is also manufactured. It is confirmed that the implemented system can monitor the environmental change inside the nacelle in real time by transmitting various information obtained by the sensors such as temperature, flame, and smoke sensor installed in the nacelle and thermal image recorded by a thermal camera to the ground control center through the PLC system. Therefore, it is, considered that the implemented system will significantly improve the reliability of the fire monitoring and prevention system of the WTGS in conjunction with the existing safety system.

Development of Ventilator without Power using Air Flow (공기흐름을 이용한 무동력 환풍장치 개발)

  • Kim, Bum-Suk;Kwon, Taek-Joo;Jeong, Ji-Hyun
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.26-31
    • /
    • 2016
  • The studies on the efficient ventilator to reduce fire and save energy have been proceeded actively. The purpose of this paper is to design a ventilator used in residential wood stove. The ventilator consists of rotation and support part, and it is operated by natural wind without power. The shape of rotation part of the ventilator is like airfoil to reinforce pressure drop. We designed direction controller for the rotation part to track the direction of wind continuously. The rotation and support part have point-contact each other to minimize a friction. We verify the properties of the proposed ventilator though simulation and experiment. The results show the proposed ventilator can exhaust safely combustion gas of the stove more than other ventilator.

Study on the Evaluation of Radiant Heat Effects of Oil Storage Tank Fires Due to Environmental Conditions (환경조건에 따른 유류저장탱크 화재의 복사열 영향 평가 연구)

  • Lee, Jeomdong;Ryu, Juyeol;Park, Seowon;Yoon, Myong-O;Lee, Changwoo
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.72-78
    • /
    • 2020
  • In this paper, the risk of damages to humans and properties due to fire explosions in gasoline storage tanks is identified, and the effects of radiant heat on adjacent tanks are evaluated to present the necessary area to secure safety. A simulation was conducted to evaluate the effect of radiant heat (Maximum emission) on adjacent tanks in an oil storage tank fire due to environmental conditions (Wind speed and temperature) in the Northern Gyeonggi Province. The result indicated that the radiant heat released in the fire of an oil storage tank was increased by approximately 1.9 times by the maximum wind speed and the difference occurred in the range of 700~800 kW by the maximum temperature. If a storage tank fire occurs, securing approximately 34.4 m of holding area is necessary. In the future, evaluating the radiant heat emitted by the fire of gasoline storage tanks will be required by applying various environmental conditions, and through this, research on specific and quantitative holding area is required.