• 제목/요약/키워드: Width of peak pressure

검색결과 50건 처리시간 0.026초

Study on the frequency of self-excited pulse jet

  • Wang, Jian;Li, Jiangyun;Guan, Kai;Ma, Tianyou
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권4호
    • /
    • pp.206-212
    • /
    • 2013
  • Self-excited pulse jet is a specific nozzle with a closed chamber which can change a continuous jet into a pulse one. Energy of the pulse jet can be output not only unevenly but also with multifrequency. With the peak pressure of pulse jet, the hitting power would be 2~2.5 times higher than that of continuous jet. In order to reveal the correlation between the self-excited pulse frequency and nozzle diameter ratio, nozzle spacing and operating pressure, the model of 3D unsteady cavitation model has been used. We found that with the same nozzle structure parameters and the different operating pressure, the self-excited frequency and the width of peak crest are different, but the wave profiles are similar. With FFT, we also found that the less bandwidth of amplitude in low frequency range will lead to the wider wave crest of outlet velocity in its time domain, and the larger force of the strike will be gained. By studying the St of self-excite nozzle, not only the frequency of a certain nozzle can be predicted, but also a nozzle structure with a certain frequency can be designed.

FIV 시험루프의 유동기인 진동 신호분석 (Flow-Induced Vibration Signal Analysis of the FIV Test Loop)

  • 이강희;강흥석;윤경호;송기남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.601-606
    • /
    • 2004
  • Vibration spectrums of the test loop according to flow conditions were analyzed in order to identify the sources of vibration at peak frequencies. While a flow condition of the sweep test was changed by varying pump rotational speed from 450 rpm to 1500 rpm by the step 150 rpm, midspan acceleration of the test section in width-direction and dynamic pressure perturbation in the test section were measured. Other sources of vibration due to the flow structure interactions, such as acoustic resonance, blade pulsing frequency and bellows wrinkles, were investigated. Pressure perturbation in the section and acoustic resonance due to branch pipe give major effects to the vibration of the test section in high frequency range of 1.5 kHz to 2.8 kHz.

  • PDF

부분 예혼합 화염에서 연소실 압력이 연료별($CH_4$, $C_2H_4$, $C_3H_8$) 연소특성과 반응영역에 미치는 영향 (Influence of Changing Combustor Pressure on Combustion Characteristics and Reaction Zone in the Partially Premixed Flame with $CH_4$, $C_2H_4$ and $C_3H_8$)

  • 손제하;김종률;최경민;김덕줄
    • 한국연소학회지
    • /
    • 제16권3호
    • /
    • pp.33-40
    • /
    • 2011
  • Combustion experiments were conducted at three different fuels ($CH_4$, $C_2H_4$ and $C_3H_8$) to investigate the effects of combustor pressure (30 ~ -30 kPa) on combustion charateristics and reaction zone structure. Regardless of the fuels, emission index of CO (EICO) increased with decreasing combustor pressure, and EICO of $C_2H_4$ was mostly affected by changing combustor pressure at subatmospheric pressure. In order to observe reaction zone, $OH^*$, $CH^*$ and ${C_2}^*$ chemiluminescence intensity were measured. The sequence of the chemiluminescence intensity peak position was affected by chemical characteristics of fuels rather than changing combustor pressure. The emission zone thickness of $C_2H_4$ and $C_3H_8$, defined by the full width at half maximum (FWHM) of $CH^*$ intensity profile, were increased with decreasing combustor pressure. however, the thickness of $C_2H_4$ exhibited the opposite tendency due to the characteristics of the fuel as the bond structure.

뇌경새(腦梗塞) 환자(患者)와 건강인(健康人)의 맥상(脈象)과 사상체질(四象體質)에 관(關)한 연구(硏究) (Comparative Study on the Pulse Wave Variables and Sasang Constitution in Cerebral Infarction Patients and Healthy Subjects)

  • 고기덕;김경요;김종열;이시우;주종천
    • 대한약침학회지
    • /
    • 제10권2호통권23호
    • /
    • pp.119-132
    • /
    • 2007
  • This study was performed to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of cerebral infarction patieno (CI), compared with those of healthy subjects, as well as 2) to determine Sasang Constitution in CI and healthy subjects. 1. Calibrated in Gwan, the amount of energy(Energy), height of main peak(H1), height of aorticvalley(H2), height of aortic peak(H3), total area of pulse wave(At), and area of main peak width(Aw) of the CI group were higher than those of the healthy group. 2. Calibrated in Cheek, Energy, H1, H2, H3, height of valve valley(H4), At, Aw, and main peak angle(MPA) of the CI group were higher than those of the healthy group. 3. Among the healthy (subjects) group, Taeumin showed the highest contact pressure(CP) and height of valve peak(H5) calibrated in Chon. The main peak width divided by whole time of pulse wave(MPW/T) calibrated in Gwan and Cheok, was highest in Soyangin and was lowest in Taeumin. The H3 divided by H1(H3/H1) and the time to valve valley minus the time to main peak and divided by T[(T4-T1)/T] calibrated in Cheek were highest in Soyangin. The time to main peak(T1) was longest in Soumin. 4. Among the CI group, At calibrated in Chon was widest in Taeumin and was narrowest in Soumin The time to aortic peak(T3) calibrated in Cheek was longest in Soumin and was shortest in Soyangin. The time to valve peak(T5) was shortest in Soyangin. 5. There were main effects of cerebral infarction in the area of systolic period(As) and area of diastolic period(Ad) calibrated in Chon, Energy calibrated in Cwan, and Energy, H1, H2, H3, (H4+H5)/Hl, and MPA calibrated in Cheek. 6. There were main effects of Sasang Constitution in (T4-T1)/T, area of systolic period(As), and Ad calibrated in Chon. 7. The interactions between the cerebral infarction and Sasang Constitution were observed in H5/H1 , T, At, As, Ad, and MPA calibrated in Chon, H4, T4, (T4-T1)/T, As, and Ad calibrated in Cwan, and 74,75, and MPW calibrated in Cheok. Therefore, we concluded that pulse analyzer was useful to determine the risk degree of cerebral infarction and Sasang Constitution.

HPHT(고온고압)에 의해 처리된 type IIa 천연 다이아몬드의 감별에 관한 연구 (A study on the identification of type IIa natural diamonds treated by the HPHT method)

  • 김영출;최현민
    • 한국결정성장학회지
    • /
    • 제14권1호
    • /
    • pp.21-26
    • /
    • 2004
  • HPHT(고온고압) 처리된 type IIa 다이아몬드의 분광분석 결과를 나타내었다. 그리고 HPHT 처리된 다이아몬드 spectrum의 특성을 이와 유사한 color와 type을 가진 처리되지 않은 다이아몬드와 비교하였다. 325nm 에서 여기된 He/Cd laser로는 HPHT 처리된 다이아몬드와 처리되지 않은 다이아몬드에 현저한 변화가 있음을 알 수 있었는데 이는 HPHT 처리된 다이아몬드의 spectrum에서 H3, H4에 관련된 peak가 제거되고 N3 system에 관련된 peak의 emission이 증가함을 보여 주었다. 또한 514nm에서 여기된 Ar-ion laser로 측정된 spectrum은 575nm와 637.1 nm에서 Nitrogen과 vacancy가 관련되어있는 N-V center가 발견 되었는데 이러한 center가 존재하고 있을 경우 637.1 nm의 FWHM의 값은 HPHT 처리된 다이아몬드와 처리되지 않은 다이아몬드를 구분할 수 있음을 보여주었다. 본 실험에서 측정된 HPHT 처리된 다이아몬드의 637.1nm $(N-V)^-$의 FWHM 값은 $19.8{\textrm}{cm}^{-1}$에서$32.1{\textrm}{cm}^{-1}$였다.

Characteristics of ZnO Thin Films Grown on p-type Si and Sapphire Substrate by Pulsed Laser Deposition

  • Lee, K. C.;Lee, Cheon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.241-245
    • /
    • 2003
  • ZnO thin films on (l00) p-type Si and sapphire substrates have been deposited by a pulsed laser deposition technique using an Nd:YAG laser with a wavelength of 266 nm. The influence of the deposition parameters such as oxygen pressure, substrate temperature and laser energy density on the properties of the grown films was studied. The experiments were performed for substrate temperatures in the range of 200∼50$0^{\circ}C$ and oxygen pressure in the range of 100∼700 sccm. All of the films grown in this experiment show strong c-axis orientation with (002) textured ZnO peak. With increasing substrate temperature, the FWHM (full width at half maximum) and surface roughness were decreased. In the case of using sapphire substrate, the intensity of PL spectra increased with increasing ambient oxygen flow rate. We investigated the structural and morphological properties of ZnO thin films using X-ray diffraction (XRD), scanning electron microscopy (SEM) and atomic force microscopy (AFM).

MO 배면전극의 제조조건이 CIGS 박막의 광특성에 미치는 영향 (Optical Properties of CIGS Films as Deposition Conditions of Mo Back Contact)

  • 김석기;이정철;강기환;윤경훈;박이준;송진수;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1518-1520
    • /
    • 2001
  • Bi-layer Mo films were deposited on sodalime glass substrates using DC magnetron sputtering. As the gas pressure and power density, the resistivity varied from $1.5{\times}10^{-5}$ to $4.97{\times}10^{-4}{\Omega}{\cdot}cm$. Furthermore, stress direction yielded compressive-to-tensile transition stress curves. The microstructure of the compressive stress films which had poor adhesion consists of tightly packed columns, but of the tensile-stressed films had less dense structure. Under all gas pressure conditions, Mo films exhibited distinctly increasing optical reflection with decreasing gas pressure. The expansion of (110) peak width with the gas pressure meant the worse crystalline growth. Also, The highest efficiency was 15.2% on 0.2 $cm^2$. The fill factor, open circuit voltage and short circuit current were 63 %, 570 mV and 42.6 mA/$cm^2$ respectively.

  • PDF

PLD를 이용한 ZnO 박막의 구조에 산소 분압 및 후열처리 온도가 미치는 영향 (Effects of Oxygen Partial Pressure and Post-Annealing Temperature on Structure of ZnO Thin Film Prepared by Pulsed Laser Deposition)

  • 조대형;김지홍;구상모;문병무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.88-89
    • /
    • 2007
  • ZnO thin films were deposited on $Al_2O_3$ (alumina) substrates by pulsed laser deposition (PLD) using Nd:YAG laser with a wavelength of 355nm, at room temperature and oxygen partial pressure of 1, 10, 30, 50, 100, and 200m Torr. Furthermore, deposited ZnO thin films were post-annealed at 400, 550, $600^{\circ}C$. The effects of oxygen partial pressure and post-annealing temperature on structural properties of the deposited films have been investigated by means of X-ray diffraction (XRD), and atomic force microscope (AFM), respectively. It has been found that ZnO thin films exhibit c-axis orientation, exhibiting an increased foil width at half maximum (FWHM) value of (002) diffraction peak at 30m Torr oxygen partial pressure and higher post-annealing temperature ($700^{\circ}C$).

  • PDF

Mo 박막의 성장조건에 따른 Cu(InGa)$Se_2$ 박막 태양전지의 광변환효율 (Photovoltaic Properties of Cu(InGa)$Se_2$ Solar Cells with Sputter Conditions of Mo films)

  • 김석기;이정철;강기환;윤경훈;박이준;송진수;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.63-66
    • /
    • 2002
  • Bi-layer Mo films were deposited on sodalime glass substrates using DC magnetron sputtering. As the gas pressure and power density, the resistivity varied from $1.5{\times}10^{-5}$ to $4.97{\times}10^{-4}{\Omega}{\cdot}cm$. Furthermore, stress direction yielded compressive-to-tensile transition stress curves. The microstructure of the compressive stress films which had poor adhesion consists of tightly packed columns, but of the tensile-stressed films had less dense structure. Under all gas pressure conditions, Mo films exhibited distinctly increasing optical reflection with decreasing gas pressure. The expansion of (110) peak width with the gas pressure meant the worse crystalline growth. Also, The highest efficiency was 15.2% on 0.2 $cm^2$. The fill factor, open circuit voltage and short circuit current were 63 %, 570 m V and 42.6 $mA/cm^2$ respectively.

  • PDF

전립선암의 온열치료를 위한 초음파변환기 개발에 관한 연구 (A study for implementation of ultrasonic transducer in the prostate cancer hyperthermia)

  • 박문규;노시철;박재현;최흥호
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.377-384
    • /
    • 2009
  • The ultrasonic hyperthermia for oncology has been developed and studied. The HIFU(high intensity focused ultrasound) is the most recent method to treat the tumor by using ultrasound. In this study, an insertion-type transducer for treating a prostate cancer, which can focus the ultrasonic beam mechanically and electrically, was designed and developed. The developed transducer was composed of three arrays, and each array has 32 elements. For the purpose of the mechanical focusing, both side arrays are slanted to the center array by $15^{\circ}$. With this structure, NFL(near field length) was set up as 30 mm. The PZT-4 and two matching layers were used, and the backing layer was excepted to prevent energy losses. The acoustic field analysis and the heating test were performed to evaluate the performance of developed transducer. The shape of an acoustic field, peak pressure, and acoustic pressure distribution were compared with numerical simulation. The NFL was 32 mm, the beam width was 5 mm, focal area was $40\;mm^2$, and peak pressure was 5.5 MPa. With heating by using developed transducer, the temperature increased up to $33^{\circ}C$ at focal zone. As a result of this study, the usefulness of suggested transducer for prostate cancer hyperthermia was confirmed by the acoustic field analysis and the heating test with TMM(tissue mimicking) phantom.