• Title/Summary/Keyword: Wide spectral range

Search Result 139, Processing Time 0.026 seconds

Research on the Technology of Alternative Continuous Wide Spectral Spatial Heterodyne Spectrometer

  • Zhang, Wenli;Tian, Fengchun;Zhao, Zhenzhen;Song, An;Zhang, Li
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.295-307
    • /
    • 2017
  • An innovative system for the alternative continuous wide spectral spatial heterodyne spectrometer (ACWS-SHS) is proposed. The relationship between the ACWS-SHS and the wide spectral spatial heterodyne spectrometer (WS-SHS) at the resolution limit, the spectral range, the grating diffraction efficiency and the interference fringes contrast ratio has been analyzed theoretically. Through the comparison of the theoretical analysis and simulation results, it is found that the two systems for the WS-SHS and the ACWS-SHS have the same resolution limit and spectral range, which are ${\delta}{\sigma}$ and ${\sigma}_{01}$, while in the ACWS-SHS system the critical diffraction efficiency of echelle grating is 68.39% and the critical contrast ratio of interference fringes is 0.4135, which is much better than the performance of the WS-SHS system. Therefore, the ACWS-SHS reduces the high requirements for the precision of equipment and expands the application field of SHS effectively.

Development of Empirical Formulas for Approximate Spectral Moment Based on Rain-Flow Counting Stress-Range Distribution

  • Jun, Seockhee;Park, Jun-Bum
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.257-265
    • /
    • 2021
  • Many studies have been performed to predict a reliable and accurate stress-range distribution and fatigue damage regarding the Gaussian wide-band stress response due to multi-peak waves and multiple dynamic loads. So far, most of the approximation models provide slightly inaccurate results in comparison with the rain-flow counting method as an exact solution. A step-by-step study was carried out to develop new approximate spectral moments that are close to the rain-flow counting moment, which can be used for the development of a fatigue damage model. Using the special parameters and bandwidth parameters, four kinds of parameter-based combinations were constructed and estimated using the R-squared values from regression analysis. Based on the results, four candidate empirical formulas were determined and compared with the rain-flow counting moment, probability density function, and root mean square (RMS) value for relative distance. The new approximate spectral moments were finally decided through comparison studies of eight response spectra. The new spectral moments presented in this study could play an important role in improving the accuracy of fatigue damage model development. The present study shows that the new approximate moment is a very important variable for the enhancement of Gaussian wide-band fatigue damage assessment.

Spectral Characteristics of 50 GHz FSR Etalon for Wide-band DWDM Application

  • Kim, Jong-Deog;Moon, Jong-Tae
    • Journal of the Optical Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.104-107
    • /
    • 2004
  • The periodic transmission spectrum of a solid etalon for wide-band capability is analyzed both theoretically and experimentally. In the transmission spectrum with an incident area of a photodetector, the peak wavelength and transmittance are deeply dependent on the incident angle and the divergence angle of the input laser beam. A thermal adjustment for a solid etalon is an optional way to control the transmission spectrum instead of the inefficient fine-angle alignment. In the result, we present the deviations of free spectral range (FSR) by the change in angle and temperature over wide wavelength range.

Development of a Fatigue Damage Model of Wideband Process using an Artificial Neural Network (인공 신경망을 이용한 광대역 과정의 피로 손상 모델 개발)

  • Kim, Hosoung;Ahn, In-Gyu;Kim, Yooil
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.1
    • /
    • pp.88-95
    • /
    • 2015
  • For the frequency-domain spectral fatigue analysis, the probability density function of stress range needs to be estimated based on the stress spectrum only, which is a frequency domain representation of the response. The probability distribution of the stress range of the narrow-band spectrum is known to follow the Rayleigh distribution, however the PDF of wide-band spectrum is difficult to define with clarity due to the complicated fluctuation pattern of spectrum. In this paper, efforts have been made to figure out the links between the probability density function of stress range to the structural response of wide-band Gaussian random process. An artificial neural network scheme, known as one of the most powerful system identification methods, was used to identify the multivariate functional relationship between the idealized wide-band spectrums and resulting probability density functions. To achieve this, the spectrums were idealized as a superposition of two triangles with arbitrary location, height and width, targeting to comprise wide-band spectrum, and the probability density functions were represented by the linear combination of equally spaced Gaussian basis functions. To train the network under supervision, varieties of different wide-band spectrums were assumed and the converged probability density function of the stress range was derived using the rainflow counting method and all these data sets were fed into the three layer perceptron model. This nonlinear least square problem was solved using Levenberg-Marquardt algorithm with regularization term included. It was proven that the network trained using the given data set could reproduce the probability density function of arbitrary wide-band spectrum of two triangles with great success.

Improvement of a Pound-Drever-Hall Technique to Measure Precisely the Free Spectral Range of a Fabry-Perot Etalon

  • Seo, Dong-Sun;Park, Chongdae;Leaird, Daniel E.;Weiner, Andrew M.
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.357-362
    • /
    • 2015
  • We examine the principle of a modified Pound-Drever-Hall (PDH) technique to measure the free spectral range of a Fabry-Perot etalon (FPE). The FPE's periodic transmission of phase-modulated light allows us to adopt a sampling theorem to develop a new relationship for the PDH error signal. This leads us to find the key parameters governing the measurement accuracy: the phase modulation index ${\beta}$ and the FPE finesse. Without any additional complexity for background noise reduction, we achieve a measurement accuracy of 0.5 ppm. The improvement is mainly attributed to the wide-band phase modulation approaching ${\beta}=10$, and partly to the use of both reflected and transmitted light from the FPE and good FPE finesse.

Perspectives on THz Time Domain Spectroscopy

  • Cheville, R.Alan
    • Journal of the Optical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.34-52
    • /
    • 2004
  • Over the past decade the experimental technique of THz time domain spectroscopy (㎔- TDS) has proved to be a versatile method for investigating a wide range of phenomena in the ㎔ or far infrared spectral region from 100 ㎓ to 5 ㎔. This paper reviews some recent results of the Ultrafast ㎔ Research Group at Oklahoma State University using ㎔-TDS as a characterization tool. The experimental technique is described along with recent results on ㎔ beam propagation and how ㎔ beam profiles arise from propagation of pulse fronts along caustics. To illustrate how spatio-temporal electric field measurements can determine material properties over a wide spectral range, propagation of ㎔ pulses through systems exhibiting frustrated total internal reflection (FTIR) are reviewed. Finally two potential metrology applications of ㎔-TDS are discussed, thin film characterization and non-destructive evaluation of ceramics. Although ㎔-TDS has been confined to the research laboratory, the focus on application may stimulate the adoption of ㎔- TDS for industrial or metrology applications.

Extension of the Dynamic Range in the CMOS Active Pixel Sensor Using a Stacked Photodiode and Feedback Structure

  • Jo, Sung-Hyun;Lee, Hee Ho;Bae, Myunghan;Lee, Minho;Kim, Ju-Yeong;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.256-261
    • /
    • 2013
  • This paper presents an extension of the dynamic range in a complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) using a stacked photodiode and feedback structure. The proposed APS is composed of two additional MOSFETs and stacked P+/N-well/P-sub photodiodes as compared with a conventional APS. Using the proposed technique, the sensor can improve the spectral response and dynamic range. The spectral response is improved using an additional stacked P+/N-well photodiode, and the dynamic range is increased using the feedback structure. Although the size of the pixel is slightly larger than that of a conventional three-transistor APS, control of the dynamic range is much easier than that of the conventional methods using the feedback structure. The simulation and measurement results for the proposed APS demonstrate a wide dynamic range feature. The maximum dynamic range of the proposed sensor is greater than 103 dB. The designed circuit is fabricated by the $0.35-{\mu}m$ 2-poly 4-metal standard CMOS process, and its characteristics are evaluated.

Development of Spectral Irradiance Measurement System (분광복사조도 측정 장치 개발)

  • Seo, Jung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.48-53
    • /
    • 2004
  • Spectral irradiance measurement system was developed to measure the spectral irradiance of optical sources in the wavelength range from 250[nm] to 1600[nm]. Our system is composed of source system, fore-optics, monochromator system, optical detector system, and automatic control system. Optical detector system with PMT, Si, InGaAs, and IR enhanced InGaAs detectors is used to measure the wide spectrum of optical sources in ultraviolet visible, and infrared wavelength regions. Spectral irradiance of the 1[kW] quartz-halogen tungsten lamp was measured and compared in the wavelength range from 250[nm] to 1600[nm]. The differences between our results and those reported by NIST are below 3[%], 3.5[%], and 5[%] in the wavelength range of 450∼700[nm], 700∼1600[nm], 250∼400[nm], respectively.

Developments of the Wide Wavelength Range Polarimeter of the Domeless Solar Telescope at the Hida Observatory

  • Anan, Tetsu;Ichimoto, Kiyoshi;Oi, Akihito;Ueno, Satoru;Kimura, Goichi;Nakatani, Yoshikazu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.86.1-86.1
    • /
    • 2011
  • We are developing a new universal spectropolarimeter on the Domeless Solar Telescope (DST) at the Hida Observatory to realize precise spectropolarimetric observations in a wide range of wavelength in visible and near infrared. The system aims to open a new window of plasma diagnostics by using Zeeman effect, Hanle effect, Stark effect, impact polarization, and atomic polarization for measuring the external magnetic field, electric field, or an anisotropy in the excitation of the atoms. The polarimeter is a successor of formerly developed polarimeter on DST, which make possible to observe a polarization in a photospheric spectral line with polarimetric accuracy of 10-2 (Kiyohara et al. 2004). The new system consists of a 60cm aperture vacuum telescope, a high dispersion vacuum spectrograph, polarization modulator / analyzer composed of a rotating waveplate whose retardation is constant for a wide range of wavelength and Wallaston prism, and a fast and large format CCD camera or IR camera. Spectral images in both orthogonal polarizations are taken simultaneously with a frame rate of ~20Hz while the waveplate rotates continuously in a rate of 1rev./sec. Thus It takes 5 ~ 60 sec to observe polarization with accuracy of 10-3 in a wide wavelength range (400 - 1100nm). We also examined a polarimetric model of the telescope with accuracy of 10-3 to calibrate instrumental polarization on some wavelengths. In this talk, I will focus on the performance of the instrument.

  • PDF

Study on Applicability of Frequency Domain-Based Fatigue Analysis for Wide Band Gaussian Process I : Rayleigh PDF (광대역 정규 프로세스에 대한 주파수 영역 기반 피로해석법의 적용성에 관한 연구 I : 레일리 PDF)

  • Choung, Joon-Mo;Kim, Kyung-Su;Nam, Ji-Myung;Koo, Jeong-Bon;Kim, Min-Soo;Shim, Yong-Lae;Urm, Hang-Sub
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.4
    • /
    • pp.350-358
    • /
    • 2012
  • This paper deals with accuracy of accumulated fatigue damage estimation using stochastic fatigue analysis method based on Rayleigh PDF. From full scale measurement data on an 8100TEU container vessel, zero-order spectral moments for wave- and vibration-induced energy spectral densities are determined on the probability level of 99%. 80 simulation cases in total are prepared according to the variation of ratio of zero-order spectral moments and center frequency of vibration ESD. By using inverse Fourier transformation and rainflow cycle counting for the combined ESD of wave and vibration, exact fatigue damages are derived. Fatigue damages in frequency domain based on Rayleigh PDF show large conservativeness compared to exact fatigue damages in times domain. The main cause of the excessive conservativeness is analyzed by two aspects: ratio of zero crossing and peak frequencies and ratio of initial zero order spectral moments and zero order spectral moments from rainflow stress range distributions. Finally, a guideline of applicability of Rayleigh PDF is proposed for wide band processes.