• 제목/요약/키워드: Wide measurement range

검색결과 485건 처리시간 0.023초

위상 검출 방식 레이저 스캐너의 APD bias 전압 특성을 이용한 검출신호세기 제어 방법 (Measured Intensity Control Method of a Phase-shift Measurement Based Laser Scanner by using APD Bias Voltage Characteristic)

  • 장준환;윤희선;황성의;박기환
    • 한국정밀공학회지
    • /
    • 제29권10호
    • /
    • pp.1096-1100
    • /
    • 2012
  • In the phase-shift measurement method, the distance light travels can be obtained based on the phase difference between the reference signal and the measured signal. When the object having various colors is measured, the intensity of the measured signal much varies even at the same distance, and it causes different phase delay due to wide dynamic range input to a signal processing circuit. In this work, an measured intensity control method is proposed to solve this phase delay problem.

Pulsed Doppler 초음파속도측정의 정확도 판정 : 유동 phantom 연구 (Accuracy of Pulsed Doppler Ultrasound Velocity Measurements : In Vitro Flow Phantom Study)

  • 김영호;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.153-156
    • /
    • 1994
  • An in vitro steady flow experiment was performed in order to test the accuracy of velocity measurement obtained through a pulsed Doppler echocardiography. A flow phantom was designed for the use in a wide velocity range at a given flow rate. The results showed that the pulsed Doppler velocity measurement obtained in this flow phantom is accurate at low flow rates. However, ultrasound velocity measurement should be performed under a careful considerations of PRF and Doppler gain settings, especially at higher flow rates.

  • PDF

Spectral interferometer를 이용한 색분산 측정방법 (Chromatic dispersion measurement method with spectral interferometer)

  • 이지용;이승락;김덕영
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 하계학술발표회 논문집
    • /
    • pp.307-308
    • /
    • 2007
  • We present a novel chromatic dispersion measurement method using a spectral domain interferometer for single mode optical fiber over a wide spectral range (200 nm). This technique is based on the Mach-Zehnder interferometer using a white light source and spectrometer. A phase was directly retrieved from a measured spectral interferogram to obtain relative group velocity, chromatic dispersion and dispersion slope. The measured results with the proposed method were compared with those obtained using a conventional measurement method. Those results have good agreement with each other. Our proposed method can simply, accurately, and quickly (< 500 ms) measure chromatic information for a short length of optical fiber as well as optical device.

  • PDF

공기압실린더의 누설유량 계측에 관한 연구 (A Study on the Measurement Method of Leakage for Pneumatic Cylinder)

  • 장지성;지상원
    • 동력기계공학회지
    • /
    • 제11권4호
    • /
    • pp.98-102
    • /
    • 2007
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measured from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing the steel wool into it. Therefore, a wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

전달율 측정에 의한 점탄성재료의 복소탄성계수 추출시의 민감도 분석 (Sensitivity Analysis in the Estimation of Complex Elastic Modulus of Viscoelastic Materials by Transmissibility Measurements)

  • 안태길;허진욱;김광준
    • 소음진동
    • /
    • 제2권2호
    • /
    • pp.99-106
    • /
    • 1992
  • The complex Young's modulus of a viscoelastic material can be obtained as a function of frequency from the measurements of relative motion between the two ends of a bar-type specimen. Non-resonance method is usually used to obtain the complex Young's modulus over wide range of frequency including resonance points, while in resonance method information at resonance frequencies only is used. However, the complex Young's modulus obtained by the non-resonance method is often unreliable in the anti-resonance frequency regions because of the measurement noise problems. In this study, the effects of the random measurement errors on estimating the complex Young's modulus are studied in the aspect of sensitivity, and how to obtain the reliable frequency region for a given measurement error level is shown. The usable frequency regions in determining the complex Young's modulus are represented by a non-dimensional parameter formed with the wave length and specimen length.

  • PDF

다기능 DO 센서용 계측시스템 개발 (Development of the Measurement System for the Multi-Functional DO Sensor)

  • 이동희;김태진;최복길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.86-88
    • /
    • 1996
  • A method is presented for the development of the PC-based measurement system on the 6 cathodes-single anode type multi-functional oxygen electrodes for detecting various components of the solution by measuring the dissolved oxygen(DO) concentration. The system is consisted with the 6 channel sensor signal modyfing circuits for the sensor and the PC interface circuits using the single chip microprocessor 80c196kc. Typical polarograms for the DO probes under test using this sensor circuits are presented. This system covers wide range of measuring time from 300sec to over 16 hour in one measurement step by programming the 9 monitor disply mode.

  • PDF

두 종모드 레이저 빛 사이의 맥놀이 신호를 이용한 간섭계에 의한 유효 광학 두께 측정 (Measurement of the effective optical thickness of optical media using intermode beat interferometer scheme)

  • 윤신영;조규만;이용산
    • 한국광학회지
    • /
    • 제8권1호
    • /
    • pp.26-30
    • /
    • 1997
  • 서로 수직으로 편광되고 두개의 종모우드로 발진하는 주파수가 안정화된 He-Ne 레이저를 이용하여 넓은 측정 범위를 갖는 헤테로다인 간섭계를 구성하였다. 두 모우드 사이의 맥놀이 주파수인 684MHz에 대한 라디오 주파수 간섭을 이용하여 약 .+-.1.74.mu.m의 분해능으로 광학매질의 광학두께를 측정할 수 있는 장치를 구성하였다. 이와 같은 측정장치를 이용하여 Nd:YAG 레이저의 수동형 Q-스위칭에 포화흡수체로 사용되고 있는 유기염료 박막의 두께와 국부적인 광학두께의 변화에 대한 map을 구할 수 있었다.

  • PDF

공압실린더의 누설유량 계측방법에 관한 연구 (A Study on the Measurement Method of Leakage Flow-rate for Pneumatic Cylinder)

  • 장지성;지상원;정지현;강보식
    • 유공압시스템학회논문집
    • /
    • 제3권1호
    • /
    • pp.15-19
    • /
    • 2006
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measure from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

RTD와 4-20[mA] 아날로그 계측용 다기능 모듈의 개발 (The Development of Multi-Function Measurement Module for RTD and 4-20[mA] Analog Input)

  • 박종찬;김병진
    • 전기학회논문지P
    • /
    • 제53권2호
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper, multi-functional measurement module for RTD and 4-20mA Analog input is presented. As you know, In many industry field, RTD has been used for measuring a temperature. Although It have good properties such as wide measurement range, accuracy, the hardware or software compensation methods were applied to better linearity in many applications. According to this paper, a simply approximation method and various measuring technique are proposed to compensate large lead's resistance influence in RTD temperature measurements. As the experiment and simulation results, it is proved that the proposed method has good performance of measuring temperature. Additionally, with the CAN based communication, remote monitoring and parameter setting functions are realized.

케이블센서를 이용한 2차원 위치측정 시스템 (A Two-Dimensional Position Sensor Using Cable Extension Transducers)

  • 홍대희
    • 한국정밀공학회지
    • /
    • 제16권9호
    • /
    • pp.159-165
    • /
    • 1999
  • Based on the cable-extension transducers, a new technique for two dimensional position measurement is developed in this paper. This new technique includes the use of two such transducers and the planar position is determined through triangulation. This paper also presents uncertainty analysis results for establishing sensor design specifications. An actual prototyped sensor system is built and its accuracy is verified through h\both experiments with coordinate measurement machines and its application to the real-time control of a high load wheeled mobile robot. This new type of position sensor can be easily used in a wide variety of automation applications in industry for two dimensional position measurements with high accuracy over a relatively large range, and it is both cast effective and robust against hostile environments.

  • PDF