• Title/Summary/Keyword: Wide Beam

Search Result 544, Processing Time 0.029 seconds

Long-baseline single-layer 2nd-order $high-T_c$ SQUID gradiometer (긴기저선을 가진 단일층 고온초전도 SQUID 2차미분기)

  • Lee Soon-Gul;Kang Chan Seok;Kim In-Seon;Kim Sang-Jae
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.6-10
    • /
    • 2005
  • We have studied feasibility of single-layer second-order $high-T_c$ SQUID gradiometers in magnetocardiography. We have measured human cardiomagnetic signals using a short-baseline (5.8 mm) single-layer second-order YBCO gradiometer in partially shielded environments. The gradiometer has an overall size of $17.6\;mm{\times}6\;mm$ and contains three parallel-connected pickup coils which are directly coupled to a step-edge junction SQUID. The gradiometer showed an unshielded gradient noise of $0.84\;pT/cm^2/Hz^{1/2}$ at 1 Hz, which corresponds to an equivalent field noise of $280\;fT/Hz^{1/2}$. The balancing factor was $10^3$. Based on the same design rules as the short-baseline devices, we have studied fabrication of 30 mm-long baseline gradiometers. The devices had an overall size of $70.2\;mm{\times}10.6\;mm$ with each pickup coil of $10\;mm{\times}10\;mm$ in outer size. As Josephson elements we made two types of submicron bridges, which are variable thickness bridge (VTB) and constant thickness bridge (CTB), from $3\;{\mu}m-wide$ and 300 nm-thick YBCO lines with a thin layer of Au on top by using a focused ion beam (FIB) patterning method. VTB was 300 nm wide, 200 nm thick, 30 nm long with Au removed and CTB 100 nm wide and 30 nm long. In temperature-dependent critical currents, $I_c(T)$, VTB showed an nonmetallic barrier-type behavior and CTB an SNS behavior. We believe that those characteristics are ascribed to naturally formed grain boundaries crossing the bridges.

  • PDF

Design of 3-component Force/Moment Sensor with Force/Moment Ratio of Wide Range (넓은 범위의 힘/모멘트비를 갖는 3분력 힘/모멘트 센서 설계)

  • Kim, Gap-Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.214-221
    • /
    • 2001
  • This paper describes the design of 3-component force/moment sensor with the force and moment ratio of wide range. It can measure the x-direction force Fx, y-direction force Fy and z-direction moment Mz simultaneously. In order to accurately measure forces and moment using 3-component force/moment sensor, it should get suitable force and moment ratio(the ratio of force Fx=200 N and moment Mz=20 Nm is ten to one), and small interference error. In this paper, in order to design the 3-component force/moment sensor with the force and moment ratio of wide range, the procedures are performed as follow : 1) the derivation of the equations to predict the bending strains on the surfaces of the plate-beams under the force or the moments, 2) the determination of the size of the sensing elements of the force/moment sensor by using the derived equations, 3) the Finite Element Method(FEM) analysis and the characteristic test for confirming the strains from the theory analysis, 4) the selection of the attachment locations of the strain gages of each sensor, 5) the analysis of the rated strain and the interference error at the attachment location of strain gages. It reveals that the rated strains calculated from the derived equations make a good agreement with the results from the Finite Element Method analysis and the characteristic test.

  • PDF

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.

The Research Relating to QA of the Absorbed Dose in the 10 MeV E-beam Facility in Accordance with the International Standards (국제표준에 따른 10 MeV급 전자빔 조사시설의 흡수선량 품질보증에 관한 연구)

  • Ha, Tae-Sung;Ahn, Cheol;Jung, Pyeong-Hwan;Cho, Jeong-Hee;Lee, Jong-Seok;Lee, Hye-Nam;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.387-394
    • /
    • 2010
  • In the field of healthcare, the conventional sterilization treatments have been replaced by irradiation methods which are in accordance with internationally well established quality standards. The quality control in radiation sterilization assures that the absorbed dose of the irradiated material is in agreement with its requirements and standards. The electron beam irradiation requires technical assessments of more process parameters than gamma irradiation does. Korea has witnessed wide uses of electron accelerators since early 2000 but there hasn't been research experiences relating to quality system in accordance with international standards. The new large scale e-beam irradiation system with the specification of 10 MeV, 8 kW was installed and operated in 2008 by Seoul Radiology Services Co. It consists of the electron accelerator, product handling system, safety, documentation and control subsystems into an integrated system to meet the requirement of the Good Manufacturing Practice such as process quality assurance and management of product tracking records. To implement the international standard such as EN ISO11137, it is necessary to understand the purposes aimed in the standard and carry out the tests following the procedures required. This study presented the specification of the e-beam facility and showed what its design requirements and features are. The test results on a variety of process parameters were presented and validated it they are within the required limits.

Studies on the Fabrication of 0.2 ${\mu}m$Wide-Head T-Gate PHEMT′s (0.2 ${\mu}m$ Wide-Head T-Gate PHEMT 제작에 관한 연구)

  • Jeon, Byeong-Cheol;Yun, Yong-Sun;Park, Hyeon-Chang;Park, Hyeong-Mu;Lee, Jin-Gu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.1
    • /
    • pp.18-24
    • /
    • 2002
  • n this paper, we have fabricated pseudomorphic high electron mobility transistors (PHEMT) with a 0.2 ${\mu}{\textrm}{m}$ wide-head T-shaped gate using electron beam lithography by a dose split method. To make the T-shape gate with gate length of 0.2 ${\mu}{\textrm}{m}$ and gate head size of 1.3 ${\mu}{\textrm}{m}$ we have used triple layer resist structure of PMMA/P(MMA-MAA)/PMMA. The DC characteristics of PHEMT, which has 0.2 ${\mu}{\textrm}{m}$ of gate length, 80 ${\mu}{\textrm}{m}$ of unit gate width and 4 gate fingers, are drain current density of 323 ㎃/mm and maximum transconductance 232 mS/mm at $V_{gs}$ = -1.2V and $V_{ds}$ = 3V. The RF characteristics of the same device are 2.91㏈ of S21 gain and 11.42㏈ of MAG at 40GHz. The current gain cut-off frequency is 63GHz and maximum oscillation frequency is 150GHz, respectively.ively.

Ferromagnetic Properties in Diluted Magnetic Semiconductors (Al,Mn)N grown by PEMBE

  • Ham, Moon-Ho;Myoung, Jae-Min
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.12-15
    • /
    • 2006
  • We present the structural, magnetic, and electrical properties in the (Al,Mn)N films with various Mn concentrations grown by plasma-enhanced molecular beam epitaxy. X-ray diffraction analyses reveal that the (Al,Mn)N films have the wurtzite structure without secondary phases. All (Al,Mn)N films showed the ferromagnetic ordering. Particularly, ($Al_{1-x}Mn_{x}$)N film with x = 0.028 exhibited the highest magnetic moment per Mn atom at room temperature. Since all the films exhibit the insulating characteristics, the origin of ferromagnetism in (Al,Mn)N might be attributed to either indirect exchange interaction caused by virtual electron excitations from Mn acceptor level to the valence band within the samples or a percolation of bound magnetic polarons arisen from exchange interaction of localized carriers with magnetic impurities in a low carrier density regime.

Estimation for River Naturality in the Hwang River (황강 수생태계에 대한 하천 자연도 평가 연구)

  • Huh, Man-Kyu
    • Journal of Environmental Science International
    • /
    • v.22 no.2
    • /
    • pp.195-203
    • /
    • 2013
  • I investigated the river morphology and river naturality according to the environment of the Hwang River. The numbers of flexions at the upstream regions were more than those of downstream regions. The Hwang River showed very low overall diversity of the flow. Materials of river shore at low channel width were mainly boulders or gravel at the upstream regions, and the middle and downstream were silts and clay. Artificial masonry and natural materials were mixed from materials of river levees. The Hwang River was some of the natural herbaceous vegetation to riparian zones. Land utilities for floodplain were extremely overall farmland were predominant, and partly used by natural vegetation in the forest, a soccer field, some park facilities, residential, and commercial facilities. The water was width sleep / rivers beam ratio of 10 to 20%. Currently estimation for river naturality widely used in rivers were consisted of a narrow wide a variety of items and did not reflect the actual.

Damage assessment of beams from changes in natural frequencies using ant colony optimization

  • Majumdar, Aditi;De, Ambar;Maity, Damodar;Maiti, Dipak Kumar
    • Structural Engineering and Mechanics
    • /
    • v.45 no.3
    • /
    • pp.391-410
    • /
    • 2013
  • A numerical method is presented here to detect and assess structural damages from changes in natural frequencies using Ant Colony Optimization (ACO) algorithm. It is possible to formulate the inverse problem in terms of optimization and then to utilize a solution technique employing ACO to assess the damage/damages of structures using natural frequencies. The laboratory tested data has been used to verify the proposed algorithm. The study indicates the potentiality of the developed code to solve a wide range of inverse identification problems in a systematic manner. The developed code is used to assess damages of beam like structures using a first few natural frequencies. The outcomes of the simulated results show that the developed method can detect and estimate the amount of damages with satisfactory precision.

Reduction of Sound Radiated Power of Clamped Beams using Filtered Velocity Feedback Controllers (Filtered Velocity Feedback 제어기를 이용한 양단지지보의 음향파워 저감)

  • Shin, Chang-Joo;Hong, Chin-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.12
    • /
    • pp.1104-1111
    • /
    • 2011
  • This paper investigates the filtered velocity feedback(FVF) controller for the reduction of the acoustic power radiated from a clamped beam. The instability problem due to the non-collocated sensor/actuator configuration when using PZT actuator should be sorted out. The roll-off property of the FVF controller at high frequency helps to alleviate the instability. The dynamics of clamped beams under forces and moments pair and the FVF controller are first formulated. The formulation of the sound radiated power is followed. The open loop transfer function(OLTF) synthesized with 100 modes is used to determine the stability of the control system. The control performance is finally estimated. The levels of the vibration and the sound radiated power are reduced in the wide bandbelow the tuning mode of the FVF controller.

Measurement of Liquid-Metal Flow with a Dynamic Neutron Radiography (중성자 래디오그래피를 이용한 액체금속 유동장 측정)

  • Cha, Jae-Eun;Saito, Yasushi
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.63-68
    • /
    • 2011
  • The flow-field of a liquid-metal system is very important for the safety analysis and the design of the steam generator of liquid-metal fast breeder reactor. Dynamic neutron radiography (DNR) is suitable for a visualization and measurement of a liquid metal flow and a two-phase flow in a metallic duct. However, the three dimensional DNR techniques is not enough to obtain the velocity information in the wide channel up to now. In this research, a high speed DNR technique was applied to visualize the heavy liquid-metal flow field in the narrow channel with the HANARO-beam facility. The images were taken with a high frame-rate neutron radiography at 250 fps and analyzed with a Particle Image Velocimetry(PIV) method. The images were compared with the results of the commercial CFX code to study the feasibility of DNR technique for the measuring the heavy liquid-metal flow field. The PIV images could discern the turbulent vortex flow in the two-dimensional narrow channel.