• Title/Summary/Keyword: Wick

Search Result 169, Processing Time 0.024 seconds

Experimental and Numerical Study on the Capillary Performance of Non-Homogeneous Micro-Post Arrays (비 균일적 마이크로 원기둥 배열을 이용한 고성능 냉각 표면)

  • Byon, Chan;Kim, Sung Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1091-1097
    • /
    • 2013
  • In this article, an advanced cooling surface based on micro-post arrays with non-homogeneous configurations is investigated and compared with conventional micro-post arrays with homogeneous configuration. The capillary performance of micro-post arrays are characterized using the capillary rate of rise experiments and numerical simulations which take into account the meniscus curvature. The experimental and numerical results show that that the capillary performance of the micro-post wick can be significantly enhanced, compared with the homogeneous type wick, by employing non-homogeneous configurations. The capillary performance is shown to be primarily a function of the solid fraction and increases linearly with decreasing solid fraction, regardless of the wick configuration, when the solid fraction is larger than 0.25. However, the capillary performance is found to be significantly reduced when the solid fraction falls below approximately 0.25.

Heat transfer characteristics of the heat pipe using simplified heat transfer model (단순 열전달 모델을 이용한 히트파이프의 열전달 성능특성에 관한 연구)

  • Seo, Jae-Hyeong;Bang, Yu-Ma;Seo, Lee-Soo;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.15-20
    • /
    • 2015
  • The objective of this study was to examine numerically the heat transfer and flow characteristics of the heat pipe with a wick using the simplified heat transfer model to enhance the cooling effects of high heat flux devices and minimizing the energy consumption for electric vehicles. The heat pipe with a wick was analyzed using commercial software with COMSOL and water was used as the working fluid. The velocity and temperature characteristics of the heat pipe were simulated numerically along the heat pipe and the local and average Nusselt numbers were calculated. As a result, the driving force occurred because of the temperature difference between the hot side and the cold side. The heat transfer of the heat pipe occurred from the hot side to the cold side and increased toward the center position. In addition, the average Nusselt numbers were 1.88 for the hot side and 0.1 for the cold side, and the maximum Nusselt number was 4.47 for the hot side and 0.7 for the cold side.

Development of the Structure for Enhancing Capillary Force of the Thin Flat Heat Pipe Based on Extrusion Fabrication (압출형 박판 히트파이프의 모세관력 향상을 위한 구조 개발)

  • Moon, Seok Hwan;Park, Yoon Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.11
    • /
    • pp.755-759
    • /
    • 2016
  • The use of heat pipes in the electronic telecommunication field is increasing. Among the various types of heat pipes, the thin flat heat pipe has relatively high applicability compared with the circular heat pipe in the electronic packaging application. The thin flat heat pipe based on extrusion fabrication has a simple capillary wick structure consisting of rectangular cross sectional grooves on the inner wall of the pipe. Although the groove serves as a simple capillary wick, and many such grooves are provided on the inner wall, it is difficult for the grooves to realize a sufficiently high capillary force. In the present study, a thin flat heat pipe with a wire bundle was developed to overcome the drawback of poor capillary force in the thin flat heat pipe with grooves, and was evaluated by conducting tests. In the performance test, the thin flat heat pipe with the wire bundle showed a lower thermal resistance of approximately 3.4 times, and a higher heat transfer rate of approximately 3.8 times with respect to the thin flat heat pipe with grooves as the capillary wick respectively. The possibility of using the wire bundle as a capillary wick in the heat pipe was validated in the present study; further study for commercializing this concept will be taken up in the future.

Growth and Yield According to Wick Number Under Wick Culture System of Potato Plug Seedlings (감자 플러그묘 심지재배에서 심지수에 따른 상위급종서의 생산성)

  • 강봉균;송창길;김찬우;박정식;문현기;오태수;오문학
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.3
    • /
    • pp.191-195
    • /
    • 2003
  • This study was conducted in 2001 to develop a technique for mass production of superior seed tuber by using a wick culture system as an alternative plan to solve problems in hydroponic culture of potato. Potato (Solanum tuberosum L. cv. Dejima) plug seedings were planted on a styrofoam bed (volume $0.032\textrm{m}^3$) containing two different media (Jeju scoria + peatmoss and perlite + peatmoss, (1:2, v/v) mixture, respectively). Each bed was equipped with various number of wicks (2, 4, 6, 8 and 10 ea/bed). After harvest, the total porosity of both media was 83-85%. Bulk density of Jeju scoria + peatmoss was higher compared to that of perlit + peatmoss. However, the number of wicks did not influence to the bulk density. Conversely, moisture capacity of Jeju scoria + peatmoss was remarkably greater than that of perlite + peatmoss and was increased from 55 to 70% as elevating number of wicks. Although the number of wicks resulted in the areal growth of plants, the total yield and the weight of tuber were highest at the bed equipped with six wicks in both media.

Stabilization of Soil Moisture and Plant Growth on a Botanical Biofilter with a Wick-Typed Humidifying Apparatus (심지형 가습장치를 이용한 식물바이오필터의 토양수분 및 식물 생육의 안정성)

  • Kim, You Na;Chun, Man Young;Lee, Chang Hee
    • Korean Journal of Plant Resources
    • /
    • v.29 no.5
    • /
    • pp.579-587
    • /
    • 2016
  • The final goal of this research is to develop a miniaturized botanical biofilter using a wick-typed automatic humidifier for stabilizing soil moisture content (SMC) and purifying indoor air pollutants by the biofilter. This new biofilter equipped with wick-typed automatic humidifier was manufactured as more compacted design removing an absorption tower-typed humidifier compared with the previous big-sized biofilter made in 2015. This study was performed to compare changes of SMCs among floors depending on the number of wicks installed on the humidifier within the novel biofilter, and to compare changes of SMCs and plant growth parameters before and after planting Spathiphyllum wallisii ‘Mauna Loa’ on the biofilter. SMCs among floors depending on the number of wicks were similar, and all regression lines of SMCs showed almost horizontal lines because of long-term stability on SMCs. Comparing plant growth parameters of S. wallisii ‘Mauna Loa’ before planting and at 30 days after planting on the biofilter, all growth parameters were not statistically significant. Thus, SMCs of the biofilter were more stabilized using this humidifying apparatus regardless of the number of wicks than the previous biofilter using absorption tower-typed humidifying apparatus.

Effects of Tuber Size on Field Growth and Yield of 'Dejima' Potatoes Produced through Wick-based Hydroponics (심지양액재배 '대지'의 씨감자 크기에 따른 포장 생육과 수량)

  • Kim, Chan-Woo;Song, Chang-Khil;Kang, Bong-Kyoon;Jeun, Young-Chull;Kang, Young-Kil
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.55 no.1
    • /
    • pp.31-37
    • /
    • 2010
  • Two field experiments were carried out in 2002 to evaluate effects of the sizes of tubers produced through a wick-based hydroponics on growth and yield of seed potatoes (Solanum tuberosum L. 'Dejima'). Nine sizes of seed tubers (<1, 1~3, 3~5, 5~7, 7~10, 10~20, 20~30, 30~50, and 50~80 g) were used in spring crop. In fall crop, however, tubers except for the 1 g and 50~80 g wereused with tubers 7 and 15 g produced through aeroponics. Emergence rate greatly increased as tuber size was increased up to 10~20 g and then leveled off in both croppings. The number of days from planting to emergence in spring crop was about 34 days regardless of tuber size, while that in fall crop decreased from 34 to 16 days as tuber size increased from 1~3 to 30~50 g. The number of stems per plant, stem length and diameter, and leaf size tended to increase with tuber size. As the seed tuber size increased up to 10~20 g, the number of tubers per plant, average tuber weight, total and seed tuber yields linearly increased and then slowly increased with seed tuber size. Total and seed potato yields were not significantly different between tubers produced through a wick-based hydroponics and an aeroponics when similar sized tubers were planted in the fall cropping.