• Title/Summary/Keyword: Whole body frame

Search Result 35, Processing Time 0.019 seconds

Silhouette-based Motion Estimation for Movement Education of Young Children (유아의 동작 교육을 위한 실루엣 기반 동작 추정)

  • Shin, Young-Suk;Kim, Hey-Jeong;Lee, Jeong-Wuk;Lee, Kyoung-Mi
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.4
    • /
    • pp.273-284
    • /
    • 2008
  • Movements are a critical ability to young children's whole development, including physical, social/emotional, and cognitive development. This paper proposes the method to estimate movements suitable for young children's body conditions. The proposed method extracts a silhouette in each frame of videos that are obtained by deploying two video cameras by compensating illuminations, removing background and conducting morphology operations. And we extract silhouette feature values: an area, the ratio of length to width, the lowest foot position, and 7 Hu moments. Also, the area and movements of sub-area are used as local features. For motion estimation, we used probability propagation of the features extracted from the front and side frames. The proposed estimation algorithm is demonstrated for seven movements, walking, jumping, hopping, bending, stretching, balancing, and turning.

Impact of nanocomposite material to counter injury in physical sport in the tennis racket

  • Hao Jin;Bo Zhang;Xiaojing Duan
    • Advances in nano research
    • /
    • v.14 no.5
    • /
    • pp.435-442
    • /
    • 2023
  • Sports activities, including playing tennis, are popular with many people. As this industry has become more professionalized, investors and those involved in sports are sure to pay attention to any tool that improves athletes' performance Tennis requires perfect coordination between hands, eyes, and the whole body. Consequently, to perform long-term sports, athletes must have enough muscle strength, flexibility, and endurance. Tennis rackets with new frames were manufactured because tennis players' performance depends on their rackets. These rackets are distinguished by their lighter weight. Composite rackets are available in many types, most of which are made from the latest composite materials. During physical exercise with a tennis racket, nanocomposite materials have a significant effect on reducing injuries. Materials as strong as graphite and thermoplastic can be used to produce these composites that include both fiber and filament. Polyamide is a thermoplastic typically used in composites as a matrix. In today's manufacturing process, materials are made more flexible, structurally more vital, and lighter. This paper discusses the production, testing, and structural analysis of a new polyamide/Multi-walled carbon nanotube nanocomposite. This polyamide can be a suitable substitute for other composite materials in the tennis racket frame. By compression polymerization, polyamide was synthesized. The functionalization of Multi-walled carbon nanotube (MWCNT) was achieved using sulfuric acid and nitric acid, followed by ultrasonic preparation of nanocomposite materials with weight percentages of 5, 10, and 15. Fourier transform infrared (FTIR) and Nuclear magnetic resonance (NMR) confirmed a synthesized nanocomposite structure. Nanocomposites were tested for thermal resistance using the simultaneous thermal analysis (DTA-TG) method. scanning electron microscopy (SEM) analysis was used to determine pores' size, structure, and surface area. An X-ray diffraction analysis (XRD) analysis was used to determine their amorphous nature.

High Resolution MR Images from 3T Active-Shield Whole-Body MRI System (3T 능동차페형 전신 자기공명영상 장비로부터 얻어진 고해상도 자기공명영상)

  • Bo-Young Choe;Sei-Kwon Kang;Myoung-Ja Chu;Hyun-Man Baik;Euy-Neyng Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.138-148
    • /
    • 2001
  • Purpose : Within a clinically acceptable time frame, we obtained the high resolution MR images of the human brain, knee, foot and wrist from 3T whole-body MRI system which was equipped with the world first 37 active shield magnet. Materials and Methods : Spin echo (SE) and Fast Spin Echo (FSE) images were obtained from the human brain, knee, foot and wrist of normal subjects using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. For acquisition of MR images of knee, foot and wrist, we employed a homemade saddle shaped RF coil. Topical common acquisition parameters were as follows: matrix=$512{\times}512$, field of view (FOV) =20 cm, slice thickness = 3 mm, number of excitations (NEX)=1. For T1-weighted MR images, we used TR = 500 ms, TE = 10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE = 108 ms. Results : Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.5T system. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter. Conclusion The present results demonstrate that the MR images from 3T system could provide better diagnostic quali\ulcorner of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

A Study on the Excavated Sab(a funeral fan) from Lime-filled Tomb and Lime-layered Tomb during the Joseon Dynasty (조선시대 회격·회곽묘 출토 삽(翣)에 대한 고찰)

  • Yi, Seung Hae;An, Bo Yeon
    • Korean Journal of Heritage: History & Science
    • /
    • v.41 no.2
    • /
    • pp.43-59
    • /
    • 2008
  • Sap(?, a funeral fan) is a funeral ceremonial object used in association with a Confucian ceremonial custom, which was crafted by making a wooden frame, attaching a white cloth or a thick paper onto it, drawing pictures on it, and making a holder for a handle. According to Liji(Records of Rites), Sap was used since the Zhou Dynasty, and these Chinese Sap examples are no big different than the Korean Sap examples, which were described in Joseon Wangjo Sillok(Annals of the Joseon Dynasty), Gukjo Oryeui(the Five Rites of the State), and Sarye Pyeollam(Handbook on Four Rituals). This study explored Sap excavated in lime-filled tombs and lime-layered tombs of aristocrats dating back to Joseon, as well as their historical records to examine Sap's characteristics according to their examples, manufacturing methods, and use time. The number and designs of Sap varied according to the deceased' social status aristocrats used mainly one pair of 亞-shaped Bulsap, and a pair of Hwasap with a cloud design depicted on it. A Sap was wrapped twice with Chojuji paper or Jeojuji paper, and for the third time with Yeonchangji paper. Then, it was covered with a white ramie, a hemp, a cotton, a silk satin, etc. Bobul(an axe shape and 亞-shape design) was drawn on both sides of Sap, and a rising current of cloud was drawn at the peripheral area mainly with red or scarlet pigments. Sap, which were excavated from aristocrats'lime-filled and lime-layered tombs, are the type of Sap which were separated from its handle. These excavated Sap are those whose long handles were burnt during the death carriage procession, leaving Sap, which later were erected on both sides of the coffin. The manufacturing process of excavated relics can be inferred by examining them. The excavated relics are classified into those with three points and those with two points according to the number of point. Of the three-point type(Type I), there is the kind of relic that was woven into something like a basket by using a whole wood plate or cutting bamboo into flat shapes. The three-point Sap was concentrated comparatively in the early half of Joseon, and was manufactured with various methods compared with its rather unified overall shape. In the meantime, the two-point Sap was manufactured with a relatively formatted method; its body was manufactured in the form of a rectangle or a reverse trapezoid, and then its upper parts with two points hanging from them were connected, and the top surface was made into a curve(Type II) or a straight line(Type III) differentiating it from the three-point type. This manufacturing method, compared with that of the three-point type, is simple, but is not greatly different from the three-point type manufacturing method. In particular, the method of crafting the top surface into a straight line has been used until today. Of the examined 30 Sap examples, those whose production years were made known from the buried persons'death years inscribed on the tomb stones, were reexamined, indicating that type I was concentrated in the first half of the $16^{th}$ century. Type II spanned from the second half of the $16^{th}$ century to the second half of the $17^{th}$ century, and type III spanned from the first half of the $17^{th}$ century to the first half of the $18^{th}$ century. The shape of Sap is deemed to have changed from type I to type II and again from type II to type III In the $17^{th}$ century, which was a time of change, types II and III coexisted. Of the three types of Sap, types II and III re similar because they have two points; thus a noteworthy transit time is thought to have been the middle of the $16^{th}$ century. Type I compared with types II and III is thought to have required more efforts and skills in the production process, and as time passed, the shape and manufacturing methods of Sap are presumed to have been further simplified according to the principle of economy. The simplification of funeral ceremonies is presumed to have been furthered after Imjinwaeran(Japanese invasion of Joseon, 1592~1598), given that as shown in the Annals of King Seonjo, state funerals were suspended several times. In the case of Sap, simplification began from the second half of the $16^{th}$ century, and even in the $18^{th}$ century, rather than separately crafting Sap, Sap was directly drawn on the coffin cover and the coffin. However, in this simplification of form, regulations on the use of Sap specified in Liji were observed, and thus the ceremony was rationally simplified.