• Title/Summary/Keyword: Wet-solution

Search Result 571, Processing Time 0.034 seconds

Spectrophotometric Determination of Traces of Phosphorus in Semiconductor-grade Trichlorosilane (반도체급 삼염화실란 중의 극미량 인의 분광광도법적 정량)

  • Dong Kwon Kim;Myoung Wan Han;Hee Young Kim
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.2
    • /
    • pp.255-260
    • /
    • 1992
  • A procedure for spectrophotometric determination of traces of phosphorus(P) in high-purity trichlorosilane(TCS) is proposed using an adsorptive separation. $PCl_3$, which is a dominant P impurity within TCS, is first oxidized by oxygen to a stable form as $POCl_3$. $AlCl_3$ is selected as an adsorbent which forms a thermally stable complex with $POCl_3$ in TCS and can be well dissolved in aqueous ethanol solution. The proposed adsorptive separation method is free from the formation of silica gel and gas bubbles during the colorimetric analysis of TCS. The method reveals that the P concentration in a semiconductor-grade TCS is 5.32 ${\mi}g/l$ within the standard deviation of ${\pm}$ 17%. On the other hand, the P concentration of the purified TCS which is separated from the $AlCl_3$${\cdot}$$POCl_3$ complex is reduced to be less than 0.15 ${\mi}g/l$, showing the efficient applicability of $AlCl_3$ to the wet chemical analysis. The proposed method is also tested to verify the effectiveness of other well-known adsorbents.

  • PDF

Measurement of I-TEDA Removal Rate Using QCM in Supercritical Carbon Dioxide (초임계이산화탄소 하에서 QCM을 이8한 I-TEDA의 제거특성 측정)

  • Yoo, Jae-Ryong;Koh, Moon-Sung;Sung, Jin-Hyun;Lee, Jeong-Ken;Park, Kwang-Heon
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2008
  • The radioactive wastes generated from the nuclear industry can be divided into the forms of solid, liquid, or gas. Radioactive methyl iodide, a gaseous radioactive waste, is absorbed by activated carbon with 5 wt% of Trietylenediamine (1,4-diazania-bicycle[2.2.2]octane, TEDA) impregnated on the surface. Methyl Iodide ($CH_3I$) is combined chemically with TEDA (the final product : I-TEDA). To recycle radioactive activated carbon, removal of I-TEDA from activated carbon is needed. A wet method for recycling impregnated active carbon was developed to remove radioactive I-TEDA using an acetonitrile solution, which produces lots of secondary wastes. We suggest the removal of I-TEDA by supercritical carbon dioxide with co-solvents. In this experiment, we used a quartz crystal microbalance (QCM) for measuring the removal rate of the I-TEDA. From the experimental results, methanol was found to be the optimum co-solvent, and the optimum conditions such as temperature, pressure, and co-solvent flow rate were obtained. Possibility of using supercritical fluid in the removal of I-TEDA from radioactive activated carbon was also discussed.

  • PDF

The Solubility of Ozone in Deionized Water and its Cleaning Efficiency (초순수내에서의 오존의 용해도와 세정효과)

  • Han, Jeoung-Hoon;Park, Jin-Goo;Kwak, Young-Shin
    • Korean Journal of Materials Research
    • /
    • v.8 no.6
    • /
    • pp.532-537
    • /
    • 1998
  • The purpose of this study was to investigate the behavior of ozone in DI water and the reaction with wafers during the semiconductor wet cleaning process. The solubility of ozone in DI water was not only dependent on the temperature but also directly proportional to the input concentration of ozone. The lower the initial ozone concentration and the temperature, the longer the half-life time of ozone. The reaction order of ozone in DI water was calculated to be around 1.5. The redox potential reached a saturation value in 5min and slightly increased as the input ozone concentrations increased. The completely hydrophilic surface was created in Imin when HF etched silicon wafer was cleaned in ozonized DI water containing higher ozone concentrations than 2ppm. Spectroscopic ellipsometry measurements showed that the chemical oxide formed by ozonized DI water was measured to be thicker than that by piranha solution. The wafers contaminated with a non-ionic surfactant were more effectively cleaned in ozonized DI water than in piranha and ozonized piranha solutions.

  • PDF

Engineering Performance of Extruded Fly Ash Cement Panel with Bottom Ash (잔골재로서의 바텀애시를 사용한 플라이애시 시멘트 압출경화체의 공학적 특성)

  • Lee, Myeong-Jin;Kim, Jin-Man;Han, Dong-Yeop;Choi, Duck-Jin;Lee, Keun-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.3
    • /
    • pp.252-260
    • /
    • 2015
  • The aim of this research is providing the fundamental data for treating and recycling the byproducts by using the wet processed bottom ash as a fine aggregate replacement for cement-based extruded panel. Although the cement-based extruded panel was used mainly as a cladding component with its high strength and outstanding durability, it was hardly spread because of low economic feasibility due to the high cost of additives or fibers which were used to achieve 14 MPa of flexural strength as a cladding material. As a solution of this drawback, by the previous research, it was possible to replace cement by fly ash up to 80 % by decreasing quality criteria with restricting the application to indoor purpose. In this research, based on the previous research, by using the bottom ash as a replacement of fly ash, improvement of shape retention performance is tried. As a result of the experiment on evaluating the optimum content and PSD of bottom ash, as the fineness modulus and content of bottom ash was increased, the extruding performance was decreased and penetration resistance was increased. Additionally, the optimum content and the maximum particle size was found as 20 %, and 0.3 mm, respectively.

Quality Assessment of Tropospheric Delay Estimated by Precise Point Positioning in the Korean Peninsula

  • Park, Han-Earl;Roh, Kyoung Min;Yoo, Sung-Moon;Choi, Byung-Kyu;Chung, Jong-Kyun;Cho, Jungho
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.3 no.4
    • /
    • pp.131-141
    • /
    • 2014
  • Over the last decade, the Global Navigation Satellite System (GNSS) has been increasingly utilized as a meteorological research tool. The Korea Astronomy and Space Science Institute (KASI) has also been developing a near real-time GNSS precipitable water vapor (PWV) information management system that can produce a precise PWV for the Korean Peninsula region using GNSS data processing and meteorological measurements. The goal of this paper is to evaluate whether the precise point positioning (PPP) strategy will be used as the new data processing strategy of the GNSS-PWV information management system. For this purpose, quality assessment has been performed by means of a comparative analysis of the troposphere zenith total delay (ZTD) estimates from KASI PPP solutions (KPS), KASI network solutions (KNS), and International GNSS Service (IGS) final troposphere products (IFTP) for ten permanent GNSS stations in the Korean Peninsula. The assessment consists largely of two steps: First, the troposphere ZTD of the KNS are compared to those of the IFTP for only DAEJ and SUWN, in which the IFTP are used as the reference. Second, the KPS are compared to the KNS for all ten GNSS stations. In this step, the KNS are used as a new reference rather than the IFTP, because it was proved in the previous step that the KNS can be a suitable reference. As a result, it was found that the ZTD values from both the KPS and the KNS followed the same overall pattern, with an RMS of 5.36 mm. When the average RMS was converted into an error of GNSS-PWV by considering the typical ratio of zenith wet delay and PWV, the GNSS-PWV error met the requirement for PWV accuracy in this application. Therefore, the PPP strategy can be used as a new data processing strategy in the near real-time GNSS-PWV information management system.

The Possibility of Environmental Paraquat Exposure (파라콰트의 환경성 노출 가능성)

  • Oh, Se-Hyun;Choi, Hong-Soon;You, Ho-Young;Park, Jun-Ho;Song, Jae-Seok
    • Journal of agricultural medicine and community health
    • /
    • v.36 no.4
    • /
    • pp.218-226
    • /
    • 2011
  • Objectives: Paraquat (PQ) is a widely used ionic pesticide that is fatal when ingested accidentally or for suicidal purposes. It is thought that chronic exposure of PQ is related with the development of Parkinson's disease, but epidemiological studies have not yet confirmed that theory. This study attempted to estimate the possibility of environmental PQ exposure through soil and water. Materials and Methods: We analyzed the amount of decomposed PQ solution in wet soil after exposure to ultraviolet light. An artificial rainfall condition was simulated over soil sprayed with PQ to measure the amount of eluted PQ. In addition, PQ was diluted in water from three differently rated rivers and the changes in PQ concentration were measured after ultraviolet exposure over one month. High performance liquid chromatography/ultra violet detection was used to analyze the concentrations of PQ. Results: In the method we used, the recovery rate of PQ showed a precision rate less than 5%, an accuracy greater than 88%, and the calibration equation was y=5538.8x-440.01($R^2$=0.9985). There were no significant differences in the concentrations of PQ obtained from the three specimens over a 1-week period. From the PQ-sprayed soil, the artificial rainfall conditions showed no PQ elution over a 1-month period, and there was no significant differences in PQ concentrations according to ultraviolet exposure among the three samples. Conclusions: PQ remains well adsorbed naturally in soil. However, it may still exist in an integrated state for a long time in the hydrosphere, so the possibility of PQ exposure through drinking water cannot be disqualified.

EFFECTS OF CONDENSATION TECHNIQUES AND CANAL SIZES ON THE MICROLEAKAGE OF ORTHOGRADE MTA APICAL PLUG IN SIMULATED CANALS (모조 근관의 크기와 충전 방법이 orthograde MTA apical plug의 미세누출에 미치는 영향)

  • Nam, Deuk-Lim;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.208-214
    • /
    • 2009
  • The purpose of this study was to compare the dye leakage of MTA (mineral trioxide aggregate) apical plug produced by two orthograde placement techniques (hand condensation technique and ultrasonically assisted hand condensation technique). To simulate straight canal, 60 transparent acrylic blocks with straight canal were fabricated. These transparent acrylic blocks were divided into 2 groups (Group C; hand condensation technique (HC) and Group U; ultrasonically assisted hand condensation technique (UAHC)) of 30 blocks with each MTA application method. Each group was divided into 2 subgroups (n=15) with different canal size of #70 (subgroup C70 and subgroup U70) and #120 (subgroup C120 and subgroup U120). After apical plug was created, a wet paper point was placed over the MTA plug and specimen was kept in a humid condition at room temperature to allow MTA to set. After 24 hours, remaining canal space was backfilled using Obtura II. All specimens were transferred to floral form socked by 0.2% rhodamine B solution and stored in 100% humidity at room temperature. After 48 hours, resin block specimens were washed and scanned using a scanner. The maximum length of micro leakage was measured from the scanned images of four surfaces of each resin block using Photoshop 6.0. Statistical analysis was performed with Mann-Whitney U test. Group U of UAHC had significantly lower leakage than Group C of HC in #70-size canal (subgroup U70) (p<0.05).

Fabrication and Characterization of Lead Oxide (PbO) Film for High Efficiency X-ray Detector (고효율 X선 검출기 적용을 위한 PbO 필름 제작 및 특성 연구)

  • Cho, Sung-Ho;Kang, Sang-Sik;Choi, Chi-Won;Kwun, Chul;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.329-329
    • /
    • 2007
  • Photoconductive poly crystalline lead oxide coated on amorphous thin film transistor (TFT) arrays is the best candidate for direct digital x-ray detector for medical imaging. Thicker films with lessening density often show lower x-ray induced charge generation and collection becomes less efficient. In this work, we present a new methodology used for the high density deposition of PbO. We investigate the structural properties of the films using X-ray diffraction and electron microscopy experiments. The film coatings of approximately $200\;{\mu}m$ thickness were deposited on $2"{\times}2"$ conductive-coated glass substrates for measurements of dark current and x-ray sensitivity. The lead oxide (PbO) films of $200\;{\mu}m$ thickness were deposited on glass substrates using a wet coating process in room temperature. The influence of post-deposition annealing on the characteristics of the lead oxide films was investigated in detail. X-ray diffraction and scanning electron microscopy, and atomic force microscopy have been employed to obtain information on the morphology and crystallization of the films. Also we measured dark current, x-ray sensitivity and linearity for investigation of the electrical characteristics of films. It was found that the annealing conditions strongly affect the electrical properties of the films. The x-ray induced output charges of films annealed in oxygen gas increases dramatically with increasing annealing temperatures up to $500^{\circ}C$ but then drops for higher temperature anneals. Consequently, the more we increase the annealing temperatures, the better density and film quality of the lead oxide. Analysis of this data suggests that incorporation and decomposition reactions of oxygen can be controlled to change the detection properties of the lead oxide film significantly. Post-deposition thermal annealing is also used for densely film. The PbO films that are grown by new methodology exhibit good morphology of high density structure and provide less than $10\;pA/mm^2$ dark currents as they show saturation in gain (at approximate fields of $4\;V/{\mu}m$). The ability to operate at low voltage gives adequate dark currents for most applications and allows voltage electronics designs.

  • PDF

The Investigation of Pre-Service Elementary Teachers' Awareness on the Sources of Microplastics (미세플라스틱 배출원에 대한 초등예비교사들의 인식 조사)

  • Kyungmoon Jeon
    • Journal of Science Education
    • /
    • v.46 no.3
    • /
    • pp.223-236
    • /
    • 2022
  • The purpose of this study is to investigate pre-service elementary teachers' awareness on the sources of microplastics. The participants were 75 male and 91 female undergraduates. A 15-item survey questionnaire was developed based on prior researches regarding microplastics emission sources and were modified through expert review and preliminary research. The survey results show that over 80% of the respondents had heard of microplastics before through news, internet, TV, etc. However, they tended not to be aware that things such as lab coats, wet tissue, dust protective mask, or paper cup were made of microplastics-causing substances. For the questions on the expected situation of microplastics contamination, the frequency of their choices were relatively low in 'Tires of cars running are worn out' and 'The gum stuck to the floor becomes smaller.' These results show that many of them were not aware that synthetic fiber or synthetic rubber was one of the microplastics emission sources. Gender differences were found in the attitudes toward microplastics problems. Female students are more interested in the issues and are more willing to participate in the solution, and recognize the need for more education on microplastics. The implications and future directions for science education were discussed.

Progressive Evaluation of Concrete Deterioration Caused by Chloride-Induced Steel Corrosion Using Impact-Echo Testing (충격 반향 신호 모니터링을 통한 철근 부식 진전에 따른 콘크리트 상태 평가)

  • Rizky Pitajeng;Julfikhsan Ahmad Mukhti;Seong-Hoon Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.37-46
    • /
    • 2024
  • This study investigates the evolution of concrete damage due to chloride-induced steel corrosion through Impact-echo (IE) testing. Three reinforced concrete specimens, each measuring 1500 mm in length, 400 mm in width, and 200 mm in thickness, were fabricated using three concrete mixture proportions of blended cement types: ordinary Portland cement, ground granulated blast-furnace slag and fly ash. Steel corrosion in the concrete was accelerated by impressing a 0.5 A current following a 35-day cycle of wet-and-dry saturation in a 3% NaCl solution. Initial IE data collected during the saturation phase showed no significant changes, indicating that moisture had a minimal impact on IE signals and highlighting the slow progress of corrosion under natural conditions. Post-application of current, however, there was a noticeable decline in both IE peak frequency and the P-wave velocity in the concrete as the duration of the impressed current increased. Remarkably, progressive monitoring of IE proves highly effective in capturing the critical features of steel-corrosion induced concrete deterioration, such as the onset of internal damages and the rate of damage propagation. These results demonstrate the potential of progressive IE data monitoring to enhance the reliability of diagnosing and prognosticating the evolution of concrete damage in marine environment.