• Title/Summary/Keyword: Welfare medical device center

Search Result 15, Processing Time 0.02 seconds

Current Management Status of Welfare Medical Device Center (복지용구사업소 운영 현황)

  • Chin, Young Ran;Lee, Hyo Young
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.803-814
    • /
    • 2010
  • This study was conducted to understand current management status of welfare medical device centers and to suggest complementary point. Method: We surveyed 194 welfare medical device centers through the mail. The survey was done in three domains, i. e. management of service, assuring the health resources, offering the service. Results & Conclusions: According to the result of our study, several problems, which should be improved in the near future, were suggested. That were improving facilities(especially in sanitization of the devices), operating an education or training program for the personnel, and making up for the current management. It was very important for soft landing of long-term care insurance and improving quality of the elderly's life that 'Ministry of Health and Welfare' and 'National Health Insurance corporation' must support welfare medical device centers for discharging their roles

Research related to the development of an age-friendly convergence system using AI

  • LEE, Won ro;CHOI, Junwoo;CHOI, Jeong-Hyun;KANG, Minsoo
    • Korean Journal of Artificial Intelligence
    • /
    • v.10 no.2
    • /
    • pp.1-6
    • /
    • 2022
  • In this paper, the research and development aim to strengthen the digital accessibility of the elderly by developing a kiosk incorporating AI voice recognition technology that can replace the promotional signage currently being installed and spread in the elderly and social welfare centers most frequently used by the digital underprivileged. It was intended to develop a converged system for the use of bulletin board functions, educational functions, and welfare center facilities, and to seek ways to increase the user's digital device experience through direct experience and education. Through interviews and surveys of senior citizens and social welfare centers, it was intended to collect problems and pain Points that the elderly currently experience in the process of using kiosks and apply them to the development process, and improve problems through pilot services. Through this study, it was confirmed that voice recognition technology is 2 to 6 times faster than keyboard input, so it is helpful for the elderly who are not familiar with device operation. However, it is necessary to improve the problem that there is a difference in the accuracy of the recognition rate according to the surrounding environment with noise. Through small efforts such as this study, we hope that the elderly will be a little free from digital alienation.

Comparison of three different surface plank exercises on core muscle activity

  • Lee, Jin;Jeong, Kwanghyun;Lee, Hyuna;Shin, Jaeyeon;Choi, Jaelim;Kang, Seungbeom;Lee, Byoung-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.1
    • /
    • pp.29-33
    • /
    • 2016
  • Objective: This study compared the muscle activities of the erector spinae (ES), the external oblique (EO), and the rectus abdominis (RA) on three different surfaces. The purpose of this study was to determine which surface induces the highest muscle activity during the plank exercises. The information from this study can be used to recommend plank exercises to athletes and patients with weak core muscles. Design: Cross-sectional study. Methods: The subjects include 20 adult males attending S University in Seoul. Participants completed each plank exercise on three different surfaces. To measure muscle activities, researchers used the values from electromyography. The measurement excluded the initial two and final two seconds and collected information on the RA, EO, and ES in each posture of each subject. Results: The left external oblique showed significant differences between the plank position on stable ground (ST) and the plank position using a suspension device (SL) (p<0.05) and between the plank position on the unstable ground (US) and SL (p<0.05). The right rectus abdominis and left rectus abdominis displayed statistically significant differences between the ST and the US (p<0.05) and between the ST and the SL (p<0.05). The right erector spinae had a statistically significant difference between ST and US (p<0.05). Conclusions: The plank exercise strengthens the core muscles effectively, and muscle activity is related to the posture of the exercise and the location of the muscle. These results suggest that plank exercises improve muscle activities. Additionally, plank exercises can be applied to general medical care.

Development of a Excercise Prescription Device using EMG Signal (근전도 신호를 이용한 운동 처방 장치 개발)

  • Kim, Ho-joon;Lee, Jun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.3
    • /
    • pp.152-157
    • /
    • 2012
  • In this paper, we develop a muscle exercise prescription system and present a prescription method by analyzing bioelectric signal of human muscles. This system is designed to give right exercise prescriptions include strength, duration, frequency of exercise after diagnosing personal body condition using EMG(Electromyography). With the help of these prescriptions all users can keep there optimum exercise status and avoid excess exercise symptom and, we van utilize in all the measurements like abnormal posture, muscle power, muscle regidity, muscle fatigue, muscle balance. Also easily accessable system can offer variable utilizations such as in health care center, sports center, social welfare center, social medical center, school, and kinder garden.

The effect of applying a head-weight device on cervical angle and pain of neck muscles

  • Kim, Jin-Hong;Kim, Jong-Gun;Do, Kwang-Sun;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.101-105
    • /
    • 2016
  • Objective: The purpose of this study was to measure the change in pain threshold of levator scapular muscle, carniovertebral angle, and head position angle when applying a head-weight device on healthy adult. Design: Cross-sectional study. Methods: This study was conducted with 21 healthy adult male and female who voluntarily agreed to participate in this study after being informed of the purpose and method of this study. After measuring the cervical angle and pain threshold of levator scapular muscle, subject was instructed to walk for 5 minutes on a treadmill at a speed of less than 5 km/h while wearing after wearing head-weight device of 0.5 kg. Then, cervical spine angle and pain threshold of levator scapula muscle were re-measured. Measurement of cervical spine angle was conducted with photo by using the Bluebeam Revu software and the pain pressure thresholds (PPTs) were measured using an electronic algometer over potential trigger points on the body. Results: The results cervical angle showed a significant change, from $49.62^{\circ}$ to $52.10^{\circ}$ (p<0.05). PPT showed a significant change, from 30.71 to 36.89 (p<0.05). Conclusions: These findings suggest that applying head-weight device has a positive influence on increasing cervical angle and reducing pain when applied as a therapeutic intervention method of forward head posture.

The Korea Human Research Protection Program: Present and Future Direction (국내 Human Research Protection Program 도입 과정과 발전 방향에 대한 고찰)

  • Park, Sin Young;Kim, Jin Seok
    • The Journal of KAIRB
    • /
    • v.4 no.2
    • /
    • pp.30-35
    • /
    • 2022
  • The Human Research Protection Program (HRPP) includes all subject protection activities and entities involved in the process of planning, reviewing, and conducting clinical research and it ultimately aims that research can be conducted ethically and scientifically while protecting the rights and welfare of research subjects. At the beginning of its introduction in Korea, it was settled down by adopting the United States HRPP, especially the form of AAHRPP element and regulations. However, regulations and operating forms of HRPP have been changed according to the Korean domestic research environment. Actually, all the Korean institutions are adopted the Korean HRPP guidelines that have been officially announced by the Ministry of Food and Drug Safety in Korea. Recently, Korean domestic laws such as the "Advanced Regenerative Biology Act" or "In Vitro Diagnostic Medical Device Act" have been dramatically innovated and our research environment becomes to be more complicated. Therefore, the development of a suitable Korean HRPP model considering the Korean research environment is strongly demanded. For the early settle down of the Korean HRPP model, the positive incentive method should be applied, when the HRPP is operated and/ or properly operated. These improvements in the Korean HRPP environment will eventually lead to the appropriate protection of subjects who are participating in human clinical research and the quality improvement of clinical research.

  • PDF

Self-management techniques and subsequent changes in pain and function in patients with chronic low back pain (만성 요통 환자의 자가 관리 요법에 따른 통증 및 기능의 변화)

  • Choi, Jun Hyun;Kim, Eun-Shil;Yoon, Yong-Soon;Kim, Ka-Eun;Lee, Mi-Hyun;Jang, Hong-Young
    • Journal of Digital Convergence
    • /
    • v.18 no.10
    • /
    • pp.547-555
    • /
    • 2020
  • To investigate the effects of self-management programs for chronic low back pain (LBP), 63 subjects were assigned to three groups; self-exercise group (SEG), hot pack and low-frequency electrical stimulation group (HEG), and thermo-massage group (TMG). Parameters were the pain numeric rating scale (PNRS), Oswestry Disability Index (ODI), Roland Morris Disability Questionnaire (RMDQ) and Relapse frequency (RF). PNRS, ODI and RMDQ of SEG and TMG sustained effectiveness, however, PNRS, which improved after treatment in HEG, worsened in 6 month. Between the groups, all parameters were better in SEG and TMG compare to HEG. Exercise and thermo-massage can be considered as useful self-management performed at home to prevent the relapse of chronic LBP.

Inter-device Mutual authentication and Formal Verification in M2M Environment (M2M 환경에서 장치간 상호 인증 및 정형검증)

  • Bae, WooSik
    • Journal of Digital Convergence
    • /
    • v.12 no.9
    • /
    • pp.219-223
    • /
    • 2014
  • In line with the advanced wireless communication technology, M2M (Machine-to-Machine) communication has drawn attention in industry. M2M communication features are installed and operated in the fields where human accessibility is highly limited such as disaster, safety, construction, health and welfare, climate, environment, logistics, culture, defense, medical care, agriculture and stockbreeding. In M2M communication, machine replaces people for automatic communication and countermeasures as part of unmanned information management and machine operation. Wireless M2M inter-device communication is likely to be exposed to intruders' attacks, causing security issues, which warrants proper security measures including cross-authentication of whether devices are legitimate. Therefore, research on multiple security protocols has been conducted. The present study applied SessionKey, HashFunction and Nonce to address security issues in M2M communication and proposed a safe protocol with reinforced security properties. Notably, unlike most previous studies arguing for the security of certain protocols based on mathematical theorem proving, the present study used the formal verification with Casper/FDR to prove the safety of the proposed protocol. In short, the proposed protocol was found to be safe and secure.

The immediate effectiveness of mobile game-based instruction with an extracorporeal biofeedback device for an exercise program to improve pelvic floor muscle contraction in healthy subjects

  • Kang, Hyo Jeong;Kim, Mi-Hwa;Hwang, Ji Hye;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.3
    • /
    • pp.209-214
    • /
    • 2020
  • Objective: Using biofeedback in instructing pelvic floor muscle (PFM) activation is a great method to provide information on muscle contraction. This study aimed to determine the immediate effectiveness of a mobile game-based instruction with an extracorporeal biofeedback device (EBD) to improve PFM contraction in healthy subjects. Design: Cross-sectional study. Methods: Sixteen healthy subjects (4 men and 12 nulliparous women; age, 31±5 years) were enrolled. The subjects were randomly categorized into two groups, those who were to receive instructions on how to contract the PFM by using the EBD (n=7) and those who were to undergo a transabdominal ultrasonography (TAUS; n=9) with biofeedback. PFM function was measured as the displacement (mm) of PFM elevation by using the TAUS before and after the instructions in each group. Results: The EBD and TAUS groups showed a significant increase in the displacement of PFM elevation after the instructions from 5.93±4.03 mm to 7.62±3.77 mm and from 5.27±3.39 mm to 7.47±2.79 mm, respectively (p<0.05). No significant differences were found between the two groups. Conclusions: The results of this study indicated that instructions for PFM contraction using the EBD and TAUS showed an immediate effect; however, no significant difference in effectiveness was observed between the two instruction methods. Therefore, not only can the TAUS method be used but the EBD method can also be used as a PFM instruction method for noninvasive procedures. However, further studies are needed to demonstrate the effectiveness of training and exercise on larger sample sizes that includes patient populations with PFM dysfunction.

An Experimental Study for the Prevention of CT Contrast Media Extravasation with Extravasation Detection Accessory System in Femoral Vein of Rabbit (가토 정맥에서 CT 조영제의 혈관외유출 예방을 위한 EDA 시스템의 실험적 연구)

  • Kweon, Dae-Cheol;Jeong, Seok-Hee;Yang, Sung-Hwan;Cho, Mun-Son;Jang, Keun-Jo;Kim, Sun-Geun;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.238-245
    • /
    • 2006
  • To assess the ability of an extravasation defection accessory (EDA) to detect the clinically important extravascular Injection of iodinated contrast material that was delivered with an automated mechanical power injector. The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The EDA system was composed of a strain gage, an amplifier and a computer-based system. In the rabbit experimental cases, there were seven true-positive cases (range of the extravasation volumes: $14{\sim}23 ml$). The algorithm results showed seven true-positive cases (range of the extravasation volumes: $7{\sim}16ml$), nineteen true-negative cases, two false-positive cases and no false-negative cases. The EDA system had a sensitivity of 100% and a specificity of 90% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

  • PDF