• 제목/요약/키워드: Welded steel members

검색결과 81건 처리시간 0.03초

Measurement and assessment of imperfections in plasma cut-welded H-shaped steel columns

  • Arasaratnam, P.;Sivakumaran, K.S.;Rasmussen, Kim J.R.
    • Steel and Composite Structures
    • /
    • 제6권6호
    • /
    • pp.531-555
    • /
    • 2006
  • H-shaped welded steel column members are fabricated by welding together pre-cut flanges and the web. Modern fabricators are increasingly using plasma-cutting technique instead of traditional flame cutting. Different fabrication techniques result in different degrees of geometric imperfections and residual stresses, which can have considerable influence on the strength of steel columns. This paper presents the experimental investigation based temperature profiles, geometric imperfections, and built-in residual stresses in plasma cut-welded H-shaped steel column members and in similar flame cut-welded H-shaped steel columns. Temperature measurements were taken during and immediately after the cutting operations and the welding operations. The geometric imperfections were established at closely spaced grid locations on the original plates, after cutting plates into plate strips, and after welding plate strips into columns. Geometric imperfections associated with plasma cut element and members were found to be less than those of the corresponding elements and members made by flame cutting. The "Method of Section" technique was used to establish the residual stresses in the plate, plate strip, and in the welded columns. Higher residual stress values were observed in flame cut-welded columns. Models for idealized residual stress distributions for plasma cut and flame cut welded sections have been proposed.

용접형강의 직접강도법 개발에 관한 연구 고찰 (The Development of the Direct Strength Method for Welded Steel Members)

  • 류승완;박성웅;권영봉
    • 한국강구조학회 논문집
    • /
    • 제27권2호
    • /
    • pp.231-241
    • /
    • 2015
  • 직접강도법은 NAS(2004)와 AS/NZS 4600(2005)에 의해서 냉간성형강재의 설계에 처음 채택되었다. 이 설계법은 용접형강 부재에도 효과적으로 적용이 가능하다고 판단된다. 본 논문에서는 최근 수행된 용접형강 부재의 직접강도법 개발에 대해서 살펴보고자 한다. 용접형강 압축 및 휨부재의 설계강도식은 H, C, RHS, CHS 형강, 플레이트거더 및 보강판 단면의 실험 결과에 근거하여 개발 되었다. 직접강도법과 현행 설계기준에 의해 예측된 강도의 비교 결과를 통하여 직접강도법을 적용하여 좌굴혼합이 발생하는 용접형강 기둥 및 보 부재의 압축, 휨 및 전단강도를 합리적으로 산정할 수 있는 것을 입증하였다.

Direct strength method for high strength steel welded section columns

  • Choi, Jong Yoon;Kwon, Young Bong
    • Steel and Composite Structures
    • /
    • 제29권4호
    • /
    • pp.509-526
    • /
    • 2018
  • The direct strength method adopted by the AISI Standard and AS/NZS 4600 is an advanced design method meant to substitute the effective width method for the design of cold-formed steel structural members accounting for local instability of thin plate elements. It was proven that the design strength formula for the direct strength method could predict the ultimate strength of medium strength steel welded section compressive and flexural members with local buckling reasonably. This paper focuses on the modification of the direct strength formula for the application to high strength and high performance steel welded section columns which have the nominal yield stress higher than 460 MPa and undergo local buckling, overall buckling or their interaction. The resistance of high strength steel welded H and Box section columns calculated by the proposed direct strength formulae were validated by comparison with various compression test results, FE results, and predictions by existing specifications.

Behavior and design of stainless steel tubular member welded end connections

  • Kiymaz, Guven;Seckin, Edip
    • Steel and Composite Structures
    • /
    • 제17권3호
    • /
    • pp.253-269
    • /
    • 2014
  • Among the various alternatives to make a steel tubular member connection, making a slotted and gusset plate welded connection is one of the most frequently preferred alternatives. This type of connection is essentially an end connection that is made by slotting the tube longitudinally, inserting the gusset plate and then placing longitudinal fillet welds at the tube-to-plate interface. In this paper an experimental study on the behaviour of such connections in stainless steel is presented. 24 specimens were tested under concentrically applied axial tensile forces for varying tube-to-gusset plate weld lengths. Both circular and box section members were considered in the test program. Load-deformation curves were obtained and comparisons were made in terms of strength and ductility. The results obtained from the study were then critically examined and compared with currently available design guidance for slotted gusset plate welded tubular end connections. It is noted that no specific rules exist in international specifications on structural stainless steel which cover the design of such connections. Therefore, the results of this study are compared with the existing design rules for carbon steel.

Experimental study on partially-reinforced steel RHS compression members

  • Pinarbasi, Seval
    • Structural Engineering and Mechanics
    • /
    • 제63권3호
    • /
    • pp.385-400
    • /
    • 2017
  • This paper presents an experimental study on the behavior of axially-loaded steel RHS (rectangular hollow section) compression members that are partially reinforced along their lengths with welded steel plates. 28 slender column tests were carried out to investigate the effects of the slenderness ratio of the unreinforced member and the ratio of the reinforced length of the member to its entire length. In addition to the slender column tests, 14 stub-column tests were conducted to determine the basic mechanical properties of the test specimens under uniform compression. Test results show that both the compressive strength and stiffness of an RHS member can be increased significantly compared to its unreinforced counterpart even when only the central quarter of the member is reinforced. Based on the limited test data, it can be concluded that partial reinforcement is, in general, more effective in members with larger slenderness ratios. A simple design expression is also proposed to predict the compressive strength of RHS columns partially reinforced along their length with welded steel plates by modifying the provisions of AISC 360-10 to account for the partial reinforcement.

CHARACTERISTICS OF ROLLED H SECTION STEEL WELDS JOINTED BY NEWLY DEVELOPED FLASH WELDING SYSTEM

  • Kim, You-Chul;Oku, Kentaro;Umekuni, Akira;Fujii, Mitsuru
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.826-830
    • /
    • 2002
  • In the civil engineering and architecture fields, welding for large sectional members, such as I section steel and H section steel, are usually performed. a flash welding system, by which large I section steel or H section steel can be welded for a short time, was newly developed. In order to know the basic characteristics of welded joints, the specimens were cut out from flash welded joints, and tensile and fatigue experiments were carried out. The joint efficiency of welded joints by flash welding is 100% for the specimens with reinforcements and 93% for without reinforcements. The fatigue strength of welded joints with reinforcement was about 50% of that of the base metal. Removing the reinforcement generated by flash welding, fatigue strength of flash welded joints became 75% of that of the base metal. In case of flash welded joints with reinforcements, after a couple of fatigue cracks had propagated, ductile fracture occurred at the toe. In flash welded joints without reinforcements, fracture occurred at the bond or at HAZ (Heat Affected Zone). In case of fracture at the bond, fracture was brittle, and in case at HAZ, fracture was ductile.

  • PDF

T형 강관 용접 이음부의 잔류응력 생성기구에 관한 연구 (A Study on the Production Mechanisms of Residual Stress in Welded T-joint of Steel Pipe Member)

  • 장경호;장갑철;경장현;이은택
    • Journal of Welding and Joining
    • /
    • 제21권6호
    • /
    • pp.40-45
    • /
    • 2003
  • Steel members have advantages of resisting torsion and axial compression. In design, residual stresses at the welded joint of T-shape steel pipes are one of the most important points to be considered. In this paper, characteristics of residual stresses of welded joints are clarified by carrying out 3D non-steady heat conduction analysis and 3D thermal elastic-plastic FE-analysis. According to the results, the production mechanism of residual stresses at the welded joint of T-shape steel pipe is clarified. In this paper, circumferential stresses depended on thermal histories but axial and radial stresses were more dependent on geometrical shape than thermal histories. Residual stresses in the axial direction on the lower part of pipe member were tensile, controlled by geometrical shape. However, in case of middle part, residual stresses in all the directions were controlled by thermal histories.

A study on the structural performance of new shape built-up square column under concentric axial load

  • Kim, Sun-Hee;Yom, Kyong-Soo;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제18권6호
    • /
    • pp.1451-1464
    • /
    • 2015
  • Recently, in recognition of their outstanding structural performance, the use of Concrete Filled Steel Tube (CFT) columns has been increased. New shape welded built-up square tube was developed by the authors for broader usability using thin steel plates which were bent to be L-shaped (Channel) and each unit members were welded to form square steel tube as an cost-efficient use of expensive steel. In addition, since the rib placed at the center of the tube width acts as an anchor; higher load capacity of buckling is achievable. In order to apply the new shape built-up square columns, the structural behavior and stress distribution with parameter width of thickness (b/t), with and without rib were predicted. The New shape welded built-up square tube effectively delayed the local buckling of the steel tube, which led to a greater strength and ductility than regular HSS.

On the direct strength and effective yield strength method design of medium and high strength steel welded square section columns with slender plate elements

  • Shen, Hong-Xia
    • Steel and Composite Structures
    • /
    • 제17권4호
    • /
    • pp.497-516
    • /
    • 2014
  • The ultimate carrying capacity of axially loaded welded square box section members made of medium and high strength steels (nominal yield stresses varying from 345 MPa to 460 MPa), with large width-to-thickness ratios ranging from 35 to 70, is analyzed by finite element method (FEM). At the same time, the numerical results are compared with the predicted results using Direct Strength Method (DSM), modified DSM and Effective Yield Strength Method (EYSM). It shows that curve a, rather than curve b recommended in Code for design of steel structures GB50017-2003, should be used to check the local-overall interaction buckling strength of welded square section columns fabricated from medium and high strength steels when using DSM, modified DSM and EYSM. Despite all this, EYSM is conservative. Compared to EYSM and modified DSM, DSM provides a better prediction of the ultimate capacities of welded square box compression members with large width-thickness ratios over a wide range of width-thickness ratios, slenderness ratios and steel grades. However, for high strength steels (nominal yield strength greater than 460 MPa), the numerical and existent experimental results indicate that DSM overestimates the load-carrying capacities of the columns with width-thickness ratio smaller than 45 and slenderness ratio less than 80. Further, for the purpose of making it suitable for a wider scope, DSM has been modified (called proposed modified DSM). The proposed modified DSM is in excellent agreement with the numerical and existing experimental results.

직교이방성 강바닥판 피로와 구조부재의 관계에 대한 연구 (A Study for Relation Between Fatigue and Structural Members on Othortropic Steel Deck)

  • 박종인;홍성남;김태완;박선규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권3호
    • /
    • pp.41-50
    • /
    • 2012
  • 강재의 품질향상으로 강교에 있어서 재료자체의 파괴보다는 반복하중에 의한 피로균열 문제가 더욱 중요한 요소가 되었다. 재료의 항복으로 인한 교량의 붕괴 등의 사례는 거의 보고되고 있지 않지만 용접부에 발생하는 피로균열에 대한 사례는 매우 많이 보고되고 있다. 종리브와 횡리브, 데크 플레이트로 구성된 직교이방성 강바닥판의 피로응력은 강바닥판을 구성하는 요소들의 구성 형태 및 물성과 밀접한 관련이 있다. 본 논문에서는 Pelikan-Esslinger method와 signed Von-Mises 등가응력 개념을 활용하여 직교이방성 강바닥판의 피로응력을 산정하는 방법을 제시하고, 직교이방성 강바닥판 구성요소들의 구성형태와 물성을 변화시켜 피로응력에 미치는 영향을 분석하였다. 직교이방성 강바닥판의 피로응력과 구성요소의 상관관계 경향을 분석함으로써 설계 및 유지보수 시에 더 효율적인 대안을 찾는데 도움이 될 수 있을 것이다.