A study on the structural performance of new shape built-up square column under concentric axial load  

Kim, Sun-Hee (Department of Architectural Engineering, University of Seoul)
Yom, Kyong-Soo (Harmony Engineering)
Choi, Sung-Mo (Department of Architectural Engineering, University of Seoul)
Publication Information
Steel and Composite Structures / v.18, no.6, 2015 , pp. 1451-1464 More about this Journal
Abstract
Recently, in recognition of their outstanding structural performance, the use of Concrete Filled Steel Tube (CFT) columns has been increased. New shape welded built-up square tube was developed by the authors for broader usability using thin steel plates which were bent to be L-shaped (Channel) and each unit members were welded to form square steel tube as an cost-efficient use of expensive steel. In addition, since the rib placed at the center of the tube width acts as an anchor; higher load capacity of buckling is achievable. In order to apply the new shape built-up square columns, the structural behavior and stress distribution with parameter width of thickness (b/t), with and without rib were predicted. The New shape welded built-up square tube effectively delayed the local buckling of the steel tube, which led to a greater strength and ductility than regular HSS.
Keywords
built-up square column; composite effect; width of thickness; concentric axial load;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 AISC (2005, 2010), Steel Construction Manual, American Institute of Steel Construction Inst.
2 Bahrami, A., Wan Badaruzzamana, W.H. and Osman, S.A. (2011), "Nonlinear analysis of concrete-filled steel composite columns subjected to axial loading", Struct. Eng. Mech., Int. J., 39(3), 383-398.   DOI
3 Eurocode 4 (2004), Design of composite steel and concrete structures; EN 1994-1-1:2004, European Committee for Standardization.
4 Fujimoto, T., Mukai, A., Nishiyama, I. and Sakino, K. (2004), "Behavior of eccentrically loaded concrete-filled steel tubular columns", J. Struct. Eng., 130(2), 203-212.   DOI
5 Furlong, R.W. (1967), "Strength of steel-encased concrete beam columns", J. Struct. Div., 93, 113-124.
6 Hajjar, J.F. and Gourley, B.C. (1996), "Representation of concrete-filled steel tube cross-section strength", J. Struct. Eng., 122(11), 1327-1336.   DOI
7 KBC (2005, 2009), Korean Building Code; Architectural Institute of Korea.
8 Lee, S.H., Yang, I.S. and Choi, S.M. (2010), "Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms", Steel Compos. Struct., Int. J., 10(3), 711-722.
9 Lee, S.H., Kim, S.H., Kim, Y.H., Tao, Z. and Choi, S.M. (2011), "Water-pressure test and determination of welding-throat-depth for welded built-up square CFST column", J. Construct. Steel Res., 67(7), 1065-1077.   DOI
10 Park, R. and Paulay, T. (1933), Reinforced Concrete Structures, A Wiley - Interscience Publication; John Wiley & Sons.
11 Schneider, S.P. (1998), "Axially loaded concrete-filled steel tubes", J. Struct. Eng., 124(10), 1125-1138.   DOI
12 Tomii, M. and Sakino, K. (1979), "Elasto-plastic behavior of concrete filled square steel tubular beam-columns", Transact. Architect. Inst. Japan, 280, pp. 111-120.   DOI
13 Uy, B. and Bradford, M.A. (1996), "Elastic local buckling of steel plates in composite steel-concrete members", Eng. Struct., 18(3), 193-200.   DOI