On the direct strength and effective yield strength method design of medium and high strength steel welded square section columns with slender plate elements  

Shen, Hong-Xia (School of Civil Engineering, Xi'an University of Architecture and Technology)
Publication Information
Steel and Composite Structures / v.17, no.4, 2014 , pp. 497-516 More about this Journal
Abstract
The ultimate carrying capacity of axially loaded welded square box section members made of medium and high strength steels (nominal yield stresses varying from 345 MPa to 460 MPa), with large width-to-thickness ratios ranging from 35 to 70, is analyzed by finite element method (FEM). At the same time, the numerical results are compared with the predicted results using Direct Strength Method (DSM), modified DSM and Effective Yield Strength Method (EYSM). It shows that curve a, rather than curve b recommended in Code for design of steel structures GB50017-2003, should be used to check the local-overall interaction buckling strength of welded square section columns fabricated from medium and high strength steels when using DSM, modified DSM and EYSM. Despite all this, EYSM is conservative. Compared to EYSM and modified DSM, DSM provides a better prediction of the ultimate capacities of welded square box compression members with large width-thickness ratios over a wide range of width-thickness ratios, slenderness ratios and steel grades. However, for high strength steels (nominal yield strength greater than 460 MPa), the numerical and existent experimental results indicate that DSM overestimates the load-carrying capacities of the columns with width-thickness ratio smaller than 45 and slenderness ratio less than 80. Further, for the purpose of making it suitable for a wider scope, DSM has been modified (called proposed modified DSM). The proposed modified DSM is in excellent agreement with the numerical and existing experimental results.
Keywords
medium and high strength steel; welded square box section; compression member; local-overall interaction buckling; ultimate carrying capacity; direct strength method; effective yield strength method; FEM;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 American Iron and Steel Institute (AISI) (2001), North American Specifications for the Design of Cold-Formed Steel Structural Members, Washington D.C., USA.
2 American Iron and Steel Institute (AISI) (2004), Supplement 2004 to the North American Specifications for the Design of Cold-Formed Steel Structural Members, Washington D.C., USA.
3 Becque, J. and Rasmussen, Kim J.R. (2009), "A numerical investigation of local-overall interaction buckling of stainless steel lipped channel columns", J. Constr. Steel Res., 65(8-9), 1685-1693.   DOI   ScienceOn
4 Becque, J., Lecce, M. and Rasmussen, Kim J.R. (2008), "The direct strength method for stainless steel compression members", J. Constr. Steel Res., 64(11), 1231-1238.   DOI   ScienceOn
5 Degee, H., Detzel, A. and Kuhlmann, U. (2008), "Interaction of global and local buckling in welded RHS compression members", J. Constr. Steel Res., 64(8-9), 755-765.   DOI
6 Chen, S.F. (1992), Steel Structures, China Architecture & Building Press, Beijing, China. [In Chinese]
7 Chen, S.F. (2009), "Capacity calculation of welded axially compressed members with thin-walled box section", Prog. Steel Build. Struct., 11(6), 1-7. [In Chinese]
8 de Miranda Batista, E. (2009), "Local-global buckling interaction procedures for the design of cold-formed columns: Effective width and direct method integrated approach", Thin-Wall. Struct., 47(11), 1218-1231.   DOI   ScienceOn
9 EN 1993-1-1 (2005), Design of Steel Structures-Part 1-1: General rules and rules for buildings.
10 GB 50017-2003 (2003), Code for Design of Steel Structures, Beijing.
11 Georgieva, I., Schueremans, L., Vandewalle, L. and Pyl, L. (2012), "Design of built-up cold-formed steel columns according to the direct strength method", Procedia Eng., 40, 119-124.   DOI
12 Guo, Y.L. (1992), "Ultimate load behavior of welded thin-walled stub columns under combined loading of axial compression and bending", Comput. Struct., 42(4), 591-597.   DOI   ScienceOn
13 Kwon, Y.B., Kim, N.G. and Hancock, G.J. (2007), "Compression tests of welded section columns undergoing buckling interaction", J. Constr. Steel Res., 63(12), 1590-1602.   DOI   ScienceOn
14 Rusch, A. and Lindner, J. (2001), "Remarks to the direct strength method", Thin-Wall. Struct., 39(9), 807-820.   DOI   ScienceOn
15 Landesmann, A. and Camotim, D. (2013), "On the Direct Strength Method (DSM) design of cold-formed steel columns against distortional failure", Thin-Wall. Struct., 67, 168-187.   DOI
16 Little, G.H. (1979), "The strength of square steel box columns-design curves and their theoretical basis", Struct. Engr., 57A(2), 49-61.
17 Pircher, M., O'Shea, M.D. and Bridge, R.Q. (2002), "The influence of the fabrication process on the buckling of thin-walled steel box sections", Thin-Wall. Struct., 40(2), 109-123.   DOI   ScienceOn
18 Schafer, B.W. (2008), "Review: The direct strength method of cold-formed steel member design", J. Constr. Steel Res., 64(7-8), 766-778.   DOI   ScienceOn
19 Shen, H.X. (2012), "Ultimate capacity of welded box section columns with slender plate elements", Steel Compos. Struct., Int. J., 13(1), 15-33.   DOI
20 Shahbazian, A. and Wang, Y.C. (2011), "Application of the direct strength method to local buckling resistance of thin-walled steel members with non-uniform elevated temperatures under axial compression", Thin-Wall. Struct., 49(12), 1573-1583.   DOI
21 Shahbazian, A. and Wang, Y.C. (2012), "Direct strength method for calculating distortional buckling capacity of cold-formed thin-walled steel columns with uniform and non-uniform elevated temperatures", Thin-Wall. Struct., 53, 188-199.   DOI
22 Sputo, T. and Tovar, J. (2005), "Application of direct strength method to axially loaded perforated cold-formed steel studs: Longwave buckling", Thin-Wall. Struct., 43(12), 1852-1881.   DOI   ScienceOn
23 Tovar, J. and Sputo, T. (2005), "Application of direct strength method to axially loaded perforated cold-formed steel studs: Distortional and local buckling", Thin-Wall. Struct., 43(12), 1882-1912.   DOI   ScienceOn
24 Usami, T. and Fukumoto, Y. (1982), "Local and overall buckling of welded box columns", J. Struct. Div., 108(ST3), 525-542.
25 Usami, T. and Fukumoto, Y. (1984), "Welded box compression members", J. Struct. Eng., 110(10), 2457-2470.   DOI   ScienceOn
26 Swanson Analysis Systems Inc. (2004), Ansys Reference Manual, version 8.1.