• 제목/요약/키워드: Weight calibration

검색결과 169건 처리시간 0.027초

인터넷을 이용한 표준분동 교정 활용 (Mass Standards Calibration through Internet)

  • 이우갑;정진완;김광표
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1109-1112
    • /
    • 2003
  • Information technology has enabled mass standards calibration to be performed through internet. For this, an automatic weight handler was manufactured. During the operation the images of weight operation and the system are provided via the measurement system and a web server. The measurement system consists of a balance, a weight handler, instruments for environment measurement and a PC. The weight handler automatically loads and unloads weights on and from the weighing pan. The weight handler allows 6 series weights to be operated for weight calibration of 100-50-20-20-10-10 gram series weight. This capability could be used for "remote training" for series weight calibration.

  • PDF

온도의 영향에 대한 Weigh-In-Motion 시스템의 차량중량자료 보정기법 (Calibration Method of Vehicle Weight Data from Weigh-In-Motion System According to Temperature Effects)

  • 황의승;이상우
    • 한국도로학회논문집
    • /
    • 제12권4호
    • /
    • pp.187-196
    • /
    • 2010
  • 본 논문의 목적은 장기적인 차량중량자료의 획득을 위하여 설치된 Weigh-In-Motion(WIM)시스템의 정확도를 개선하기 위한 온도영향 보정기법을 개발하는 것이다. 이를 위해 국내 교통량통계연보에 근거하여 중차량교통량이 많은 지역 중 한 곳을 선정하고 WIM 시스템을 설치하여 2010년 1월부터 차량의 중량자료를 획득하였다. 본 연구에서는 획득한 자료 가운데 5월부터 8월까지의 WIM 자료에 대하여 온도에 따른 영향을 보정하기 위하여 화물적재량에 따른 영향을 가장 덜 받아 상대적으로 일정한 중량값을 나타내는 10종 차량(5축 세미트랙터트레일러)의 첫 번째 축의 중량자료를 이용하였다. 이로부터 일평균, 최대 및 최저기온에 따른 보정식을 개발하였다. 마지막으로 새로 얻어진 차량중량자료를 분석하여 보정방법의 적정함을 나타내었고 재현주기별 극한하중 예측을 통해 보정 전,후의 자료값의 차이를 비교하였다. 이 연구의 결과는 WIM system으로 얻게 되는 장기적인 차량중량자료의 정확도를 향상시킴으로써 도로포장 설계 및 교량설계를 위한 설계차량활하중모형의 합리적인 선택에 기여할 것으로 판단된다.

컬러재현을 위한 CMAC의 뉴로퍼지 설계 (CMAC Neuro-Fuzzy Design for Color Calibration)

  • 이철희;변오성;문성룡;임기영
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2001년도 춘계학술대회 학술발표 논문집
    • /
    • pp.97-100
    • /
    • 2001
  • CMAC model was proposed by Albus [6] to formulate the processing characteristics of the human cerebellum. Instead of the global weight updating scheme used in the back propagation, CMAC use the local weight updating scheme. Therefore, CMAC have the advantage of fast learning and high convergence rate. In this paper, simulate Color Calibration by CMAC in color images and design hardware by VHDL-base high-level synthesis.

  • PDF

특성이 다른 지게차 적재 중량 센서의 초기 값 오차 보정 (Error Calibration of Initial Value of Weight Measuring Sensors with Different Feature of Forklift)

  • 한치문;임춘식;이성렬
    • 한국항행학회논문지
    • /
    • 제23권2호
    • /
    • pp.214-220
    • /
    • 2019
  • 산업현장에서의 안전사고 빈도가 높은 지게차 전복의 주요 원인인 과적을 방지하기 위해 개발된 앵커(anchor) 볼트 형태의 strain 게이지 센서의 초기 값 오차를 보정하는 방법을 제안하였다. Strain 게이지 센서의 초기 값 오차는 앵커 볼트의 물리적이고 기계적 오차와 환경적 문제에기인하는 것을 확인하였다. 이러한 원인들을 제조 공정에서 제거하는 것은 본 연구의 범위를 벗어나는 것이기 때문에 제반 원인들을 고려한 보정 값을 찾고, 이 보정 값으로 strain 게이지 센서부를 구성하는 ADC 모듈의 초기 값을 보정하는 방법을 적용하였다. 보정 값 도출을 위하여 선형 보간법을 채택하였다. 도출한 보정 값을 4개의 strain 게이지 센서에 적용하여 시험한 결과 4개의 센서 모두 실제 중량 값과의 차이가 5% 이내가 되는 것을 확인하였다. 아울러 초기 값 보정 전에는 센서들의 ADC 값과 적재 중량 실제 값의 상관성이 없었던 점도 동시에 해결할 수 있었다.

컬러재현을 위한 CMAC의 뉴로퍼지 설계 (CMAC Neuro-Fuzzy Design for Color Calibration)

  • 이철희;변오성;문성룡;임기영
    • 한국지능시스템학회논문지
    • /
    • 제11권4호
    • /
    • pp.331-335
    • /
    • 2001
  • CMAC 모델은 인간의 소뇌의 처리 특성을 규정하기 위해 Albus[6]에 의해 제안되었다. 역전파에서 사용된 전역 가중 개선계획을 대신하기 위해, CMAC는 지역 가중 개선 계획을 사용한다. 그래서, CMAC는 빠른 학습과 높은 수렴률의 장점을 가지고 있다. 본 논문에서 컬러 영상에서 CMAC에 의해서 컬러 측정을 실험하고 그리고 높은 레벨 합성 기반인 VHDL로 설계하였다.

  • PDF

Comparison of linear and non-linear equation for the calibration of roxithromycin analysis using liquid chromatography/mass spectrometry

  • Lim, Jong-Hwan;Yun, Hyo-In
    • 대한수의학회지
    • /
    • 제50권1호
    • /
    • pp.11-17
    • /
    • 2010
  • Linear and non-linear regressions were used to derive the calibration function for the measurement of roxithromycin plasma concentration. Their results were compared with weighted least squares regression by usual weight factors. In this paper the performance of a non-linear calibration equation with the capacity to account empirically for the curvature, y = ax$^{b}$ + c (b $\neq$ 1) is compared with the commonly used linear equation, y = ax + b, as well as the quadratic equation, y = ax$^{2}$+ bx + c. In the calibration curve (range of 0.01 to 10 ${\mu}g/mL$) of roxithromycin, both heteroscedasticity and nonlinearity were present therefore linear least squares regression methods could result in large errors in the determination of roxithromycin concentration. By the non-linear and weighted least squares regression, the accuracy of the analytical method was improved at the lower end of the calibration curve. This study suggests that the non-linear calibration equation should be considered when a curve is required to be fitted to low dose calibration data which exhibit slight curvature.

Relationship between porcine carcass grades and estimated traits based on conventional and non-destructive inspection methods

  • Lim, Seok-Won;Hwang, Doyon;Kim, Sangwook;Kim, Jun-Mo
    • Journal of Animal Science and Technology
    • /
    • 제64권1호
    • /
    • pp.155-165
    • /
    • 2022
  • As pork consumption increases, rapid and accurate determination of porcine carcass grades at abattoirs has become important. Non-destructive, automated inspection methods have improved slaughter efficiency in abattoirs. Furthermore, the development of a calibration equation suitable for non-destructive inspection of domestic pig breeds may lead to rapid determination of pig carcass and more objective pork grading judgement. In order to increase the efficiency of pig slaughter, the correct estimation of the automated-method that can accommodate the existing pig carcass judgement should be made. In this study, the previously developed calibration equation was verified to confirm whether the estimated traits accord with the actual measured traits of pig carcass. A total of 1,069,019 pigs, to which the developed calibration equation, was applied were used in the study and the optimal estimated regression equation for actual measured two traits (backfat thickness and hot carcass weight) was proposed using the estimated traits. The accuracy of backfat thickness and hot carcass weight traits in the estimated regression models through stepwise regression analysis was 0.840 (R2) and 0.980 (R2), respectively. By comparing the actually measured traits with the estimated traits, we proposed optimal estimated regression equation for the two measured traits, which we expect will be a cornerstone for the Korean porcine carcass grading system.

A New Calibration Method Based on the Recursive Linear Regression with Variables Selection

  • Park, Kwang-Su;Jun, Chi-Hyuck
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1241-1241
    • /
    • 2001
  • We propose a new calibration method, which uses the linearization method for spectral responses and the repetitive adoptions of the linearization weight matrices to construct a frature. Weight matrices are estimated through multiple linear regression (or principal component regression or partial least squares) with forward variable selection. The proposed method is applied to three data sets. The first is FTIR spectral data set for FeO content from sinter process and the second is NIR spectra from trans-alkylation process having two constituent variables. The third is NIR spectra of crude oil with three physical property variables. To see the calibration performance, we compare the new method with the PLS. It is found that the new method gives a little better performance than the PLS and the calibration result is stable in spite of the collinearity among each selected spectral responses. Furthermore, doing the repetitive adoptions of linearization matrices in the proposed methods, uninformative variables are disregarded. That is, the new methods include the effect of variables subset selection, simultaneously.

  • PDF

Estimation of Cell Concentration by Light Transmitter During the Culture of Methylotrophic Yeast Pichia pastoris

  • Choi, Du-Bok;Park, Enoch Y.S.;Lee, Yong-Bo;Na, Young-Hee;Lim, Chae-Kyu
    • Mycobiology
    • /
    • 제31권4호
    • /
    • pp.226-228
    • /
    • 2003
  • The multiple correlation coefficient between the values determined by dry weight and those determined by fluorometer was observed with r=0.96 and the standard error of calibration was 0.034. Using the best calibration data, in order to reconfirm the reliability of the fluorometer results in comparison with those obtained by dry weight on the cell concentration, fedbatch cultures were carried out. The results obtained by fluorometer measurements were in good agreement with those obtained by dry weight. The on-line monitoring of cell concentration by the fermentor system linked to a computer equipped with fluorometer was successfully carried out.

초기하중 전이를 고려한 내장형 밸런스의 WEIGHT TARE 연구 (A Study on the Weight Tare of an Internal Balance Including Translation of the Initial Loads)

  • 오세윤;안승기
    • 한국항공우주학회지
    • /
    • 제31권9호
    • /
    • pp.9-17
    • /
    • 2003
  • 본 논문에서는 내장형 밸런스에 가해지는 모형중량성분의 보상을 위해 초기하중의 전이를 고려한 weight tare 계산방안을 제시하였다. 만약, 이러한 초기하중의 영향을 고려하지 않고 공력하중 데이터에 밸런스 교정관계식을 그대로 적용한다면 공력하중 전체에 걸쳐서 오차가 발생하게 된다. 본 계산방안의 신뢰성 검증을 위해 계산중량과 실측중량간의 비교 평가와 초기하중의 영향에 대한 평가를 수행하였다.