• Title/Summary/Keyword: Weight Loss 무게감소

Search Result 185, Processing Time 0.025 seconds

An Experimental Study on the Effect of Ultrasonic Cavitation on the SS400 in Marine Sludge Oil (선박 슬러지유에서 일반강에 미치는 초음파 캐비테이션 영향에 관한 실험적 연구)

  • Han Won Hui;Cho Dae Hwan;Lee Jin Yeal
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2003.11a
    • /
    • pp.157-162
    • /
    • 2003
  • The sludge oils were produced necessarily in the ships operation, so that it will be the best way to manage the sludge oils inside ship itself from a viewpoint of the prevention of marine oil pollution from ship. The ultrasonic breaking systems which recycle the sludge oil from ship into usable oil to be brunt is recognized as a most possible recycling device. In this regards, the purpose of this study is to examine erosion damage on the SS400 specimen by cavitation and the effect of impact pressure generated from the demolition of the cavity of ultrasonic vibration in the marine sludge oil environment .. The erosion damage of specimen was investigated mainly on weight loss, weight loss rate and maximum erosion rate with variation of the oil temperature as well as the change of space between transducer horn and specimen. The experimental results showed that as the space between ultrasonic vibrator horn and specimen disk increased, the weight loss and weight loss rate decreased and the values were larger in SFO than in SLO. The experimental results can be useful to the development of sludge oil disposing systems and to consider a countermeasure for the prevention of erosion damages by cavitation.

  • PDF

Fundamental Study on Cathodic Protection and Material Development as Erosion-Control Methods of Oceanic Centrifugal Pump(2) (해상용 원심펌프 임펠러의 침식억제법으로 음극방식 및 재료개발에 관한 기초연구(2))

  • Lee, Jin Yeol;Im, U Jo;O, In Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.92-92
    • /
    • 1996
  • Recently, with the rapid development in the oceanic systems such as the oceanic structures and vessel, there occurs much interest in the impingement erosion-corrosion. In this paper, Cu-metal was tested by using of erosion apparatus with water-jet type and was investigated under the behaviour of impingement erosion-corrosion according to various environmental conditions, and the properties of Cu-metal were evaluated through the measurement by weight loss, weight loss rate, protective efficiency. The results were compared with those obtained using Cu-metal applied to cathodic protection and Cu-alloys added to Zn or Al-metal. As a basis of those results, the best protective efficiencies could be taken as using cathodic protection method and Cu-alloy with Al & Zn material addings, and will be suggested as the fundamental data of the anti-impingement erosion-corrosion on Cu-metal of impeller material for oceanic centrifugal pump.

Fundamental Study on Cathodic Protection and Material Development as Erosion - Control Methods of Oceanic Centrifugal Pump(2) (해상용 원심펌프 임펠러의 침식억제법으로 음극방식 및 재료개발에 관한 기초연구 (2))

  • 이진열;임우조;오인호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.24-31
    • /
    • 1996
  • Recently, with the rapid development in the oceanic systems such as the oceanic structures and vessel, there occurs much interest in the impingement erosion-corrosion. In this paper, Cu-metal was tested by using of erosion apparatus with water-jet type and was investigated under the behaviour of impingement erosion-corrosion according to various environmental conditions, and the properties of Cu-metal were evaluated through the measurement by weight loss, weight loss rate, protective efficiency. The results were compared with those obtained using Cu-metal applied to cathodic protection and Cu-alloys added to Zn or Al-metal. As a basis of those results, the best protective efficiencies could be taken as using cathodic protection method and Cu-alloy with Al & Zn material addings, and will be suggested as the fundamental data of the anti-impingement erosion-corrosion on Cu-metal of impeller material for oceanic centrifugal pump.

  • PDF

Automatic Measurement of Respiration Rate and Weight Loss during Storage of Citrus fruits (과채류 저장시 호흡량과 중량감소의 자동계측)

  • Park, Je-Kyun;Chun, Jae-Kun;Lee, Seung-Koo;Kim, Kong-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.387-390
    • /
    • 1989
  • Citrus fruit (Citrus unshiu Marc) were stored in the facillity controlled with a microprocessor-based storage controller, and the respiration rate and weight loss of fruits were measured with the infrared gas analyzer and the strain gauge load cell. The storage conditions and measuring intervals were set by the keyboard of personal computer. The interfacing cicuitry between the computer and Z-80 microprocerssor was built with peripheral Interfacing It chips 6821 and 8255. The data measured were saved to a data file for recording and further analysis. When the fresh and bruised fruits were subjected to the storage condition for 4 days at 20 C, the respiration rate of the fresh one showed a stable value of 3-5ml $CO_2/kg$ h throughout the storage period while the bruised one exihibited an abruptly increased rate after 50 hours. And the weight loss recorded about 5% during the storage.

  • PDF

Evaluation on the Stability of Solidified Waste Forms (방사성고화체의 물리화학적 안정성 평가)

  • 유영걸;김기홍;홍권표;정의영;고덕준
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.60-70
    • /
    • 2003
  • The stability of various waste forms to meet waste acceptance criteria was evaluated by using standard test methods of U.S.A and France. Compressive strength of waste forms were above 176.03 kgf/$\textrm{cm}^2$(cement), 15 kgf/$\textrm{cm}^2$(paraffin). In the thermal cycling test, there were no any change in their feature and volume, the loss of weight was 6.15% on the average. In the immersion test for 120 days, the loss of weight of paraffin waste form was 8.85-5.14% pH=3.83. The G-Value of $H_2$ and $CH_4$ in paraffin wax at $10^8rads$ rads of exposure dose were 2.65, 0.016.

  • PDF

Effect of In Vitro Degradation on the Weight Loss and Tensile Strength of PLA/PEG Melt Blend Fiber (In Vitro 분해가 PLA/PEG 용융블렌드 섬유의 무게감량률 및 인장강도에 미치는 영향)

  • Yoon, Cheol-Soo;Ji, Dong-Sun
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.581-587
    • /
    • 2009
  • PLA/PEG blend fibers composed of poly (lactic acid) (PLA) and poly (ethylene glycol) (PEG) were prepared via melt blending and spinning for bioabsorbable filament sutures. The blend fibers hydrolyzed with the immersion in a phosphate buffer solution at pH 7.4 and $37\;^{\circ}C$ for 1~8 weeks. The effects of blending time, blend composition, and hydrolysis time on the weight loss and tensile strength of the hydrolyzed blend fibers were investigated. After hydrolysis, the weight loss of the blend fibers increased with increasing PEG content, blending time, and hydrolysis time. The tensile strength and tensile modulus of the blend fibers decreased with increasing PEG content, blending time, and hydrolysis time. Therefore, it can be concluded that the weight loss of the PLA/PEG blend fibers was less than 0.9% even at hydrolysis time of 2 weeks and their strength retentions were over 90%.

A Erosion Aspect of SS400 by Cavity Collapse Fluctuation in Marine Sludge Oil (선박 슬러지유 환경에서의 캐비티 붕괴유동에 따른 SS400의 침식양상)

  • 한원희;이진열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.328-336
    • /
    • 2002
  • decrease in efficiency due to cavity fluid fluctuation. The purpose of this study is to examine erosion aspect on the SS400 specimen by cavitation and the effect of impact pressure generated from the demolition of the cavity of ultrasonic vibrator horn in the marine sludge oil environment. The erosion damage of specimen was investigated mainly on weight loss, weight loss rate and maximum erosion rate with variation of the vibration amplitude of $50{\mu}m, 24{\mu}m$ as well as the change of space between transducer horn and specimen. The experimental results showed that as the space between ultrasonic vibrator horn and specimen disk increased, the weight loss and weight loss rate decreased and the values were larger in SFO than in SLO. These findings would help interpret the aspect of cavitation erosion damage in metallic materials of different operating environment and material characteristics.

Quality Change and Weight Loss of Fresh Ginseng Individually Packaged in a Soft Film According to its Storage Condition (연포장재 필름으로 개별포장한 수삼의 저장조건에 따른 외관품질 변화 및 개체무게 감소)

  • 손현주;김은희;이성계;노길봉
    • Journal of Ginseng Research
    • /
    • v.25 no.3
    • /
    • pp.122-126
    • /
    • 2001
  • Fresh ginseng was washed with water and packaged individually in a soft film bag (ONY/LDPE/L-LDPE;200${\times}$300mm, 90$\mu\textrm{m}$), then stored at 25$^{\circ}C$, 10$^{\circ}C$, or 4$^{\circ}C$ to investigate quality and weight changes of the packaged fresh ginseng according to its storage time. Softening was the major phenomenon which influenced on the quality of the packaged fresh ginseng while spoilage and color-change were relatively minor phenomena. There were very good correlations not only between the quality change rate constant and the storage temperature but between the weight change rate constant and the storage temperature. This result suggests that the shelf-life and the weight loss of the packaged fresh ginseng being store at low temperature can be estimated by an accelaerated sotrage test.

  • PDF

Study on the Characteristics of Crevice Corrosion Prevention of SS 400 in Marine Environment (해양환경 중에서 SS400강재의 간극부식방지 특성에 관한 연구)

  • 임우조;정기철;구영필;윤병두
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.152-157
    • /
    • 2001
  • This paper was studied on the characteristics of crevice corrosion prevention of SS 400 in marine environment. In NaCl solution, polarization behavior under the crevice corrosion was investigated. And Weight loss rate of SS 400 applied cathodic protection and non cathodic protection was measured according to the NaCl concentration. The main results obtained are as follows : The weight loss rate of Al-alloy galvanic anode was increased as the concentration of NaCl solution increased by 3.5% but the concentration increased over 3.5%, that of Al-alloy galvanic anode become decreased. The protective potential of SS 400 used Al-alloy galvanic anode becomes more cathodic polarization with increasing concentration of NaCl solution. Effects of oxygen on the weight loss rate of Al-alloy sacrificial anode for cathodic protection as the concentration of 3.5% NaCl solution become sensitive than that of 0% NaCl solution.

  • PDF

Analysis of the Influence of Sample Size on the Dry Weight and Singularity Weight of Hwangdeung Granite Rock Samples (황등화강암 시편의 크기에 따른 건조무게와 특이점 분석)

  • Dae-Hyoung Lee;Suk-Joo Kim
    • The Journal of Engineering Geology
    • /
    • v.34 no.1
    • /
    • pp.137-146
    • /
    • 2024
  • The pertinent Korean Industrial Standard (KS F) requires that rocks dried at 105 ± 5℃ be taken out of the oven into air and weighed on a scale. However, when rocks are exposed to air after the drying process, they absorb moisture, meaning that their weight will increase. In this study, eight cubic samples of Hwangdeung granite of different sizes were used to measure and compare the dry weight. The dry singularity weight measured in air was smaller than that measured in the drying oven. The difference in dry weight showed a positive correlation with sample size. Conversely, the difference in dry weight per unit weight of rock showed a negative correlation with sample size. The weight of a rock sample exposed to air is determined by the magnitude of the influence of convection currents occurring around the heated rock and the influence of moisture absorption in air. A singularity occurs when the magnitudes of these two effects are equal. The larger the rock sample, the longer the time taken for the singularity to occur, the greater the weight loss of the sample, and the longer the time taken for the sample to return to the initially measured weight on account of the greater moisture absorption for larger samples than smaller samples. In the future, research into the singularity and dry weights measured inside the drying oven will help to identify and address the limitations of the current KS F testing regulations.