• Title/Summary/Keyword: Weight Inversion

Search Result 55, Processing Time 0.027 seconds

Tillage Operational Analysis Based on Soil Moisture Content, Machine Speed, and Disc Space of Compact Disc Harrow

  • Okyere, Frank Gyan;Moon, Byeong Eun;Qasim, Waqas;Basak, Jayanta Kumar;Kahn, Fawad;Kang, Dae Sik;Yoon, Yong Cheol;Kim, Hyeon Tae
    • Journal of Biosystems Engineering
    • /
    • v.43 no.3
    • /
    • pp.161-172
    • /
    • 2018
  • Purpose: During tillage operations, the selection of a working machine (tool) depends on the soil conditions as well as the type of tillage operation to be performed. The goal of this research was to ascertain the effects of varying working machine parameters of a compact disc harrow on tillage operations under various soil moisture content (SMC) conditions. Methods: The working machine parameters were the disc spacing and machine speed. The tillage parameters under investigation were the soil inversion ratio (SIR), tillage cutting depth (TCD), and soil clod breakage ratio (SCB). To determine the SIR, the areas of the white regions before and after tillage were obtained. The ratio of the difference of the areas of the white regions before and after tillage to the area of the white regions before tillage was considered as the SIR. The SCB was obtained as the ratio of the weight of soil clods after sieving with a mesh size of <0.02 m to the total weight of the soil clods before sieving. The soil TCD was measured using a tape measure at random points after the tillage operation. The resulting data were statistically analyzed in a one-way analysis of variance. Results: The highest soil inversion was achieved when the machine speed was 0.2 m/s with the disc spaced at 0.2 m in the 16.5% SMC. At a 0.4-m/s machine speed and 0.3-m disc spacing the highest soil breakage was achieved in the 26.5% SMC. The highest TCD was achieved at a 0.2-m/s machine speed and 0.2-m disc spacing in the 16.5% SMC. Conclusions: It was concluded that varying the working machine parameters, such as the disc spacing and machine speed, could significantly affect the soil inversion and soil clod breakage; however, it had no significant impact on the TCD.

Assessment and Comparison of Isokinetic Strength of Hip, Knee and Ankle Joints in Young Adults

  • Kim, Yong Hwan;Jee, Hae Mi
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.9 no.1
    • /
    • pp.1426-1434
    • /
    • 2018
  • This study was conducted to observe the isokinetic strength (IS) of the hip, ankle, and knee joints in young age groups. Thirty eight men and thirty one women with mean age of $30.4{\pm}3.5$ and $32.8{\pm}4.4years$, respectively, were enrolled in this study. Measurements of hip flexion, extension, abduction, and adduction at $30^{\circ}/sec$, Knee flexion and extension at $60^{\circ}/sec$, ankle inversion, eversion, plantarflexion, and dorsiflexion $30^{\circ}/sec$ were conducted. Absolute IS (Nm), relative IS (Nm/kg), strength ratios, correlations between movements were observed. Significant differences in absolute and relative strength were observed between groups in all movement except in the relative ankle strength. Relative isokinetic strength ratios of hip flexion/extension were .45 and .55, knee flexion/extension were .84 and .89, ankle dorsi/plantarflexion were .30 and .29, and ankle eversion/inversion were .86 and .84 for men and women, respectively. In the hip extension, men had about three times the body weight, and women had about 2.5 times the strength. The abduction muscle had about 1.5 times the body weight of both men and women. Height and body weight showed the significantly strong correlating relationship with hip (r, .76-.86) and knee (r, .67-.84) strength. However, ankle strength showed the comparatively correlating relationship, especially in women (r, .03 - .36). Similar age and physique characteristics of female and male groups could provide useful isokinetic strength reference values for developing the exercise program for healthy and rehabilitation groups.

A Fast Inversion for Low-Complexity System over GF(2 $^{m}$) (경량화 시스템에 적합한 유한체 $GF(2^m)$에서의 고속 역원기)

  • Kim, So-Sun;Chang, Nam-Su;Kim, Chang-Han
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.9 s.339
    • /
    • pp.51-60
    • /
    • 2005
  • The design of efficient cryptosystems is mainly appointed by the efficiency of the underlying finite field arithmetic. Especially, among the basic arithmetic over finite field, the rnultiplicative inversion is the most time consuming operation. In this paper, a fast inversion algerian in finite field $GF(2^m)$ with the standard basis representation is proposed. It is based on the Extended binary gcd algorithm (EBGA). The proposed algorithm executes about $18.8\%\;or\;45.9\%$ less iterations than EBGA or Montgomery inverse algorithm (MIA), respectively. In practical applications where the dimension of the field is large or may vary, systolic array sDucture becomes area-complexity and time-complexity costly or even impractical in previous algorithms. It is not suitable for low-weight and low-power systems, i.e., smartcard, the mobile phone. In this paper, we propose a new hardware architecture to apply an area-efficient and a synchronized inverter on low-complexity systems. It requires the number of addition and reduction operation less than previous architectures for computing the inverses in $GF(2^m)$ furthermore, the proposed inversion is applied over either prime or binary extension fields, more specially $GF(2^m)$ and GF(P) .

The Effects of Chronic Ankle Instability on Postural Control during Forward Jump Landing (전방 점프 착지 시 만성 발목 불안정성이 자세 조절에 미치는 영향)

  • Kim, Kew-wan;Jeon, Kyoungkyu;Park, Seokwoo;Ahn, Seji
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.1
    • /
    • pp.9-16
    • /
    • 2022
  • Objective: The purpose of this study was to investigate how the chronic ankle instability affects postural control during forward jump landing. Method: 20 women with chronic ankle instability (age: 21.7 ± 1.6 yrs, height: 162.1 ± 3.7 cm, weight: 52.2 ± 5.8 kg) and 20 healthy adult women (age: 21.8 ± 1.6 yrs, height: 161.9 ± 4.4 cm, weight: 52.9 ± 7.2 kg) participated in this study. For the forward jump participants were instructed to stand on two legs at a distance of 40% of their body height from the center of force plate. Participants were jump forward over a 15 cm hurdle to the force plate and land on their non-dominant or affected leg. Kinetic and kinematic data were obtained using 8 motion capture cameras and 1 force plates and joint angle, vertical ground reaction force and center of pressure. All statistical analyses were using SPSS 25.0 program. The differences in variables between the two groups were compared through an independent sample t-test, and the significance level was to p < .05. Results: In the hip and knee joint angle, the CAI group showed a smaller flexion angle than the control group, and the knee joint valgus angle was significantly larger. In the case of ankle joint, the CAI group showed a large inversion angle at all events. In the kinetic variables, the vGRF was significantly greater in the CAI group than control group at IC and mGRF. In COP Y, the CAI group showed a lateral shifted center of pressure. Conclusion: Our results indicated that chronic ankle instability decreases the flexion angle of the hip and knee joint, increases the valgus angle of the knee joint, and increases the inversion angle of the ankle joint during landing. In addition, an increase in the maximum vertical ground reaction force and a lateral shifted center of pressure were observed. This suggests that chronic ankle instability increases the risk of non-contact knee injury as well as the risk of lateral ankle sprain during forward jump landing.

Robust Watermarking Scheme Based on Radius Weight Mean and Feature-Embedding Technique

  • Yang, Ching-Yu
    • ETRI Journal
    • /
    • v.35 no.3
    • /
    • pp.512-522
    • /
    • 2013
  • In this paper, the radius weight mean (RWM) and the feature-embedding technique are used to present a novel watermarking scheme for color images. Simulations validate that the stego-images generated by the proposed scheme are robust against most common image-processing operations, such as compression, color quantization, bit truncation, noise addition, cropping, blurring, mosaicking, zigzagging, inversion, (edge) sharpening, and so on. The proposed method possesses outstanding performance in resisting high compression ratio attacks: JPEG2000 and JPEG. Further, to provide extra hiding storage, a steganographic method using the RWM with the least significant bit substitution technique is suggested. Experiment results indicate that the resulting perceived quality is desirable, whereas the peak signal-to-noise ratio is high. The payload generated using the proposed method is also superior to that generated by existing approaches.

A Study on the Improvement of Microseismic Monitoring Accuracy by Borehole 3-Component Measurement Field Experiments (시추공 3성분 계측 현장실험을 통한 미소지진 모니터링 정확도 향상 연구)

  • Kim, Jungyul;Kim, Yoosung;Yun, Jeumdong;Kwon, Sungil;Kwon, Hyongil;Park, Seongbin;Park, Juhyun
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2017
  • In order to improve the accuracy of microseismic epicenter location through the inversion techniques using P and S wave first arrivals, field experiments of microseismic monitoring were performed using borehole 3-component geophones. The direction of epicenter was estimated from the hodograms of P-wave first arrivals through the weight drop experiments in which the $\times$ component of 3-component geophone was aligned to the magnetic north. The picking of S wave first arrival was possible in the polarization filtered data even if S waves are difficult to be identified in raw data. The inversion technique using only P wave first arrival times can often converge to the local minimum when the initial values for epicenter are largely apart from the true epicenter, so that the correct solution can not be found. To solve this problem, the epicenter determination method using differences between P and S wave arrival times was used to estimate proper initial values of epicenter. The inversion result using only P-wave first arrival times which started from the estimated initial values showed the improved accuracy of the epicenter location.

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF

A Study on Performance Improvement of Adaptive SLC System using Eigenanalysis Method (Eigenanalysis 방식을 이용한 적응 SLC(sidelobe canceller)시스템의 성능향상에 관한 연구)

  • 김세연;정신철;이병섭
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.694-704
    • /
    • 2001
  • In this work, We evaluate the performance of eigencanceller which can suppress directional interferences and noise effectively while maintaining specified beam pattern constraints. The constraints and optimal weight vector of eigencanceller vary by using interference and noise or desired signal, interference and noise as array input signal. From the analysis results in the steady state, We show that weight vectors in each case are simplified the form of projection equation that belongs to desired subspace orthogonal to interference subspace and eigencanceller has the better performance than DMI method through mathematical analysis and simulation.

  • PDF

Signal-Blocking-Based Robust Adaptive Beamforming by Interference Null Space Projection (간섭 널 공간 투사에 의한 신호차단 방식의 적응 빔 형성)

  • Choi, Yang-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.4A
    • /
    • pp.399-406
    • /
    • 2011
  • Adaptive beamformers, which utilize a priori information on the arrival angle of the desired signal. suppress interferences while maximizing their gains in the desired signal direction. However, if there exist errors in the direction information, they can suffer from severe performance degradation since the desired signal is treated as an interference. A robust adaptive beamforming method is presented which exploits the signal-blocking structure of the Duvall beamformer. The proposed method finds an interference signal space directly from correlations of received signals and then obtains a weight vector such that it is orthogonal to the space. Applying the weight vector to two sub arrays which consist of one less sensors than the original uniform lineal array (ULA), the beamformer efficiently estimates the arrival angle of the desired signal. Its computational complexity is lower than existing methods, which require matrix inversion or eigendecomposition.

Morphological study of synthesized PVDF membrane using different non-solvents for coagulation

  • Yadav, Meenakshi;Upadhyay, Sushant;Singh, Kailash;Chaturvedi, Tarun Kumar;Vashishtha, Manish
    • Membrane and Water Treatment
    • /
    • v.13 no.4
    • /
    • pp.173-181
    • /
    • 2022
  • Polyvinylidene fluoride (PVDF) flat sheet hydrophobic membranes were prepared using 16 wt% PVDF in Dimethyl acetamide (DMAc) by phase inversion technique for desalination application using Membrane Distillation (MD). In this work, the effect of coagulation mediums such as ethanol and water as well their synergistic behavior on the fabricated PVDF membrane morphology was studied using SEM. Moreover, other characteristics required for the membrane distillation applications namely porosity, hydrophobicity and tensile strength were measured using the gravimetric method, sessile drop method and universal testing machine respectively. It was observed that the membrane morphology paradigm shifted from the finger-like structure to the sponge-like structure on increasing the ethanol concentration in coagulant. The porosity of the fabricated membrane was under the required MD range and found to be 57.3% at 16 weight % of PVDF in DMAc solvent under a pure ethanol coagulant bath. Moreover, the top surface contact angle ranges from 85° to 115° on increasing the bath concentration from CBC 0 to CBC 100 at 16 weight % of PVDF in DMAc solvent.