• Title/Summary/Keyword: Wear

Search Result 7,454, Processing Time 0.036 seconds

Study on the Characteristics of Noise/Vibration in the Upright Laying Hen House (직립식 산란계사 내의 소음 진동 발생 현황 조사연구)

  • Lee S.J.;Chang D.I.;Chang H.H.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • This study was carried out to measure and analyze the characteristics of noise and vibration, and to analyze their effects on the productivity of layers, mechanical troubles, and abnormal wear-out failure of facilities and equipment of the layer house. The measurements of noise and vibration were taken at 13 layer farms nationwide for the operations of feed supplier system, feed distribution system, automatic egg collection system, ventilation system, blot conveyer for layer feces, and fur the case of with and without their operation by a sound level meter and a vibration measuring system in the layer house equipped with upright multi-tier cages. Measurement results showed that normal times were noise(N) 82 dB and vibration(V) 0.2072 cm/s, feed supplier system were 90 dB(N) and 2.8560 cm/s(V), feed distribution system were 90 dB(N) and 2.0222 cm/s(V), automatic egg collection system were 87 dB(N) and 0.1865 cm/s(V), ventilation system 88 dB(N) and 2.5364 cm/s(V), belt conveyer fur layer feces were 88 dB(N) and 0.2387 cm/s(V), and then maximum values of noise and vibration were 90 dB and 2.8560 cm/s, respectively, when feeding systems(feed supplying system and feed distribution system) were operated. Based on these results, an experiment is being conducted to find out the effect of noise and vibration on the productivity of layers in the layer house equipped with upright multi-tier cages.

  • PDF

Intercomparisonn of Techniques for Pressure Tube Inspection of Pressurized heavy Water Reactor (가압 중수로형 원자력발전소 압력관 비파괴검사기술의 상호비교)

  • Lee, Hee-Jong;Kim, Yong-Si;Yoon, Byung-Sik;Lee, Young-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.294-303
    • /
    • 2005
  • This paper describes the analysis results of a series f Round-Robin test that was performed to intercompare inspection and diagnosis techniques for characterization of pressure tube f a pressurized heavy water reactor under the Coordinated Research Project(CRP) of IAEA's nuclear Power Programme. For this test, six nations, Korea, Canada, India, Argentina, Rumania, and China that currently have pressurized heavy water reactors under operation involved, and the "KOR-1" pressure tube sample prepared by Korea was used. Two kinds of NDE technique, ultrasonic and eddy current test, were applied for these tests. The "KOR-1" pressure tube sample contains total 12 artificial flaws such as crack-like EDM notches, wear that is similar to the real flaws and can be produced on the pressure tubes during plant operation. Test results showed that seven laboratories from six nations detected all twelve flaws in "KOR-1" specimen by using ultrasonic and eddy current test methods, and ultrasonic test method was more accurate than eddy current test method in flaw detectin and sizing. ID flaws in pressure tube sample were more easily detected and accurately sized than OD flaws.

Comparison of Dose Depending on the Position when Shooting Panorama and CBCT (CBCT와 panorama 촬영시 위치에 따른 선량 비교)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.175-179
    • /
    • 2013
  • To find out the appropriate defensive measures for protectors and radiation workers in rotating radiation generating devices such as CBCT and panorama, irradiation dose depending on the position was compared and analyzed. The devices such as panorama DP-90-P PAX-500 (Vatech, Korea) and CBCT DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea) were used. As irradiation dose measuring instruments, Ion chamber model 2026 and Reader 20X5-60E were used. The exposure conditions were set as the factor used in the clinical trial. The result of the experiment showed that panorama was the highest, 81${\mu}R$, at point A where the test starts first and the lowest, 53${\mu}R$, at point D where the test ends. In case of CBCT, it was the highest, 1,021${\mu}R$, at point D where the test ends and was measured as the highest, 809.67${\mu}R$, at point A where the test starts. If protectors and radiation workers are forced to examine a patient holding him, they should be positioned in the middle of the point where X ray tube starts to rotate and the point where it ends to avoid the position where radiation dose is the most. And due to the nature of equipment, it will be the safest for them to stand at the opposite side of the machine and to uphold it from the rear rather than upholding it from the side of a patient and they should wear appropriate the protection gear.

A Study on Radiation Exposure Dose of Operator During Interventional Radiology Procedure (방사선 중재적 시술 중 시술자의 피폭선량에 대한 연구)

  • Jeon, Mi-Eun;Lim, Cheong-Hwan;Jung, Hong-Ryang;You, In-Gyu;Hong, Dong-Hee;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.219-226
    • /
    • 2012
  • Interventional radiologists are not aware of the potential injury from procedures. The purpose of this study are to evaluate radiation exposure of interventional radiologist from intervention procedures and to develop guideline of the simple methods for decreasing their radiation exposure from intervention procedure. In this study, Dosimeters were used to monitor operator doses of radiation exposure in a broad range of procedures from 20 interventional radiologist during the periods of 3 months. And, we searched protection methods of each interventional radiologist. During TACE procedure, there was using 0.5 mmPb radiation protector decreased average 89.5 % of radiation exposure. Thicker radiation protector provide decreasing radiation exposure. And radiation exposure dose decreased average 47.7 % by using pulse fluoroscopic mode. Therefore, interventional radiologist should wear protective aprons, use active shielding, monitor their doses, and know how to poisoning themselves during the procedure and operate correct of the machines for minimum dose.

A analysis of friction relation between tennis outsole and tennis playing surfaces (테니스화겉창과 테니스 스포츠바닥재간의 마찰관계상관 분석)

  • Kim, Jung-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.361-380
    • /
    • 2002
  • The purposes of this study were to a analysis of friction relation between tennis outsole and tennis playing surfaces. Tennis footwear is an important component of tennis game equipment. It can support or damage players performance and comfort. Most importantly athletic shoes protect the foot preventing abrasions and injuries. Footwear stability in court sports like tennis is incredibly important since it is estimated that as many as 45% of all lower extremity injuries occur in the foot and ankle. The friction force is the force exerted by a surface as an object moves across it or makes an effort to move across it. The friction force opposes the motion of the object. Friction results when two surfaces are pressed together closely, causing attractive intermolecular forces between the molecules of the two different surfaces. The outsole provides traction and reduces wear on the midsole. Today's outsoles address sport specific movements (running versus pivoting) and playing surface types. Different areas of the outsole are designed for the distinct frictional needs of specific movements. Traction created by the friction between the outsole and the surface allows the shoe to grip the surface. As surfaces, conditions and player motion change, traction may need to vary. An athletic shoe needs to grip well when running but not when pivoting. Laboratory tests have demonstrated force reductions compared to impact on concrete. There is a correlation between pain, injury and surface hardness. These are a variety of traction patterns on the soles of athletic shoes. Traction like any other shoe characteristic must be commensurate and balanced with the sport. The equal and opposite force does not necessarily travel back up your leg. The surface itself absorbs a portion of the force converting it to other forms of energy. Subsequently, tennis court surfaces are rated not only for pace but also for the percentage of force reduction.

Clinical Analysis of Ocular Trauma Induced by Lawn Trimmers (예초기에 의한 안 외상 환자의 임상적 고찰)

  • Kang, In-Gu;Park, Cheol-Sang;Ryu, Hyun-Sik;Heo, Sok-Jin;Chae, Youn-Sok;Kim, Hyun-Jin;Park, Seong-Soo;Lee, Mi-Jin;Jeong, Won-Joon
    • Journal of Trauma and Injury
    • /
    • v.24 no.2
    • /
    • pp.61-67
    • /
    • 2011
  • Purpose: Lawn trimmers are widely used to cut the weeds around graves in South Korea, but they can cause ocular injury. We investigate at the emergency room the incidence and the clinical features of ocular trauma induced by lawn trimmers. Methods:The authors analyzed 106 patients who visited Konyang University Hospital's emergency room from March 1, 2007, to October 31, 2011, because of ocular trauma caused by a lawn trimmer. Patients were sorted into two groups, severe ocular injury and mild ocular injury. Results: Over a 5-year period, 106 patients with ocular trauma caused by a lawn trimmer underwent clinical study. Most of the patient (103 patients) were males, and the average age of the patients was $51.75{\pm}11.66$ years. The incidence of ocular trauma peaked in the sixth decade of life. Most injuries occurred between July and September. Severe ocular injury developed in 46.2% of all patients. As age increased, so did the severity of the ocular injury. The impacting object was a small stone in 43.4% of all patients. Nobody wore protective gear. The most common diagnosis were corneal abrasion, followed by intraocular foreign body, corneal laceration, and sclera laceration. Fifty-four patients were followed up, and thirty-six patients of them had severe injury. The most common complication was a traumatic cataract. Conclusion: Ocular trauma induced by a lawn trimmer is more severe than general ocular trauma. We suggest that everyone using a lawn trimmer should wear protective gear and follow safety guidelines.

SSD-based RAID-6 System Architecture for Reliability and Performance Enhancement (신뢰성 향상과 성능개선을 위해 다양한 Erasure 코드를 적용한 SSD 기반 RAID-6 시스템 구조)

  • Song, Jae-Seok;Huh, Joon-Moo;Yang, Yu-Seok;Kim, Deok-Hwan
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.6
    • /
    • pp.47-56
    • /
    • 2010
  • HDD-based RAIDs have been used in high-capacity storage systems for traditional data server. However, their data reliability are relatively low and they consume lots of power since hard disk drive is weak on shock and its power consumption is high due to frequent spindle motor operation. Therefore, this paper presents new SSD based RAID system architecture using various erasure codes. The proposed methode applys Reed-Solomon, EVENODD, and Liberation coding schemes onto file system level and device driver level, respectively. Besides, it uses data allocation method to minimize the side effect of reducing the lifespan of SSD. Detail experimental results show that Liberation code increase wear-leveling rates of SSD based RAID-6 more than other codes. The SSD based RAID system applying erasure codes at the device driver level shows better performance than that at the file system level. I/O performance of RAID-6 system using SSD is 4.5%~8.5% higher than that of using HDD and the power consumption of the RAID system using SSD is 18%~40% less than that of using HDD.

Research on the Cognition and Education of Safety for Children (아동의 안전에 관한 인식과 교육 실태 조사 연구)

  • 이한용;우종웅;김일영
    • Korean Journal of Health Education and Promotion
    • /
    • v.18 no.3
    • /
    • pp.59-75
    • /
    • 2001
  • It is necessary to examine from primary school children's viewpoint to perception of safety as to how they cope with a condition threatening safety at the realistic world with risky environment and whether knowledge obtained through education is transmitted to action in a correct way. For this, this study explored and analyzed children's perspective to safety felt in life, their achievement of education to safety as trainees, and their perception extent to safety. As a result of it, following conclusion could be obtained. First, as for safety on their way to school and home, the lower grade they were, the more they felt safe, but the higher they were, the more they felt uneasy, which was examined that they generally had uncomfortable mind. Second, as for whether safety education was performed or not, it was indicated that safety education was generally executed, but lower graders responded that safety education was executed, but high graders responded that it was not executed. Third, as for observance of traffic rules, it was examined lower graders kept them well, but higher graders did not do so. Fourth, as for safety of play, it was indicated lower graders wore protective equipment by parents' concern, but higher graders did not wear them since they were full of confidence counting on their capability. Fifth, as for life safety, it was indicated the area most preferentially educated from parents' viewpoint was traffic safety, and the next ones were gas and fire safety. Sixth, as for fire safety, it was indicated they did not play with fire, but higher graders compared to lower ones, played with fire as the means of curiosity and play. Thus, curricula for children's safety education executed from adults' viewpoint should be established, and assessment of children's safety education should get out of the limitation of execution of safety education to habituated action by the transmission of children's knowledge. Also it is urgent to develop programs with which to perform children;'s education at the level of children, establish and operate safety education facilities for practice education that teachers and children can receive safety education through experience by building up children's safety education related entities. And it is thought that safety should not left to only children, but their safety would be kept by developing and training safety education programs to all organizations and individuals related to safety.

  • PDF

Experimental Study for The Development of a Blower to Extend The Life of The Impeller and Reduce The Power Cost by Changing the Air Flow (공기흐름 변경으로 임펠러의 수명연장과 전력비 절감을 위한 송풍기 개발을 위한 실험적 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul;Sohn, Sang-Suk;Kim, Young-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.219-225
    • /
    • 2020
  • In this study, the prototype of a blower was designed and made to develop a long-life blower with a volume flow rate of 10,000 ㎥/min with a required total pressure efficiency of 83% or more. Five experimental impellers with various lengths of dust deflectors were manufactured and used for the erosion experiments. The erosion test was conducted by operating for 160 hours in a self-produced closed loop-type erosion test apparatus. A prototype of a model blower was designed, fabricated, and tested. The results revealed a total pressure, air volume flow rate, and efficiency of 690.6 mmAq, 16,243.6 ㎥/min, and 83.6%, respectively, as the result of conversion to a blower based on the measured value of the blower model. The prototype was designed and fabricated as the experimental erosion equipment of the blower. A blower with a dust deflector was developed by performing the erosion experiments under harsh conditions. The blower showed an improved effect of more than 190% based on the wear thickness of the impeller compared to a conventional blower without a dust deflector.

A Study on Face Types and Glasses Wear of Young Peoples (청년들의 얼굴형태와 안경착용에 관한 연구)

  • Kim, Hye-Dong;Kim, Hyun-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.35-38
    • /
    • 2007
  • This study surveyed on eye size, face types and glasses wears of normal 100 young peoples from 20 to 30 years old. The analysis of data resulted in as follows: 1. The vertical eye size were in case of below 2.4 mm (2%), 2.5-2.9 mm (40%), 3.0-3.5 mm (57%), and in case of high 3.6 mm (1%). 2. The horzontal eye size were in case of below 1.1 mm (52%), 1.2-1.4 mm (28%), 1.5-1.7 mm (18%), and in case of high 1.8 mm (2%). 3. As a whole, the face types were oval type (29%), round type (24%), square type (18%), and triangle type (2%). 4. As the male, the face types were oval type (32%), round type (10%), square type (26%), and triangle type (32%). 5. As the female, the face types were oval type (18%), round type (40%), square type (12%), and triangle type (30%). 6. As a whole, the FPD size were in case of larger than PD (49%), in case of suitable (25%), in case of smaller than PD (49%). 7. As the male, the FPD size were in case of larger than PD (28%), in case of suitable (36%), and in case of smaller than PD (32%). 8. As the female, the FPD size were in case of larger than PD (44%), in case of suitable (26%), and in case of smaller than PD (30%).

  • PDF