• 제목/요약/키워드: Weak ground

검색결과 366건 처리시간 0.022초

연약점토층위 이층지반 지표면 재하시 지중응력 특성연구 (A Study on the Distribution Stresses beneath Loaded Ground Surface Area of Double Strata Ground on Soft Clay Layers)

  • 이인형;임종석
    • 한국농공학회논문집
    • /
    • 제47권6호
    • /
    • pp.47-57
    • /
    • 2005
  • Stress distribution in soils is the very important element to design and to solve the problems of settlement, safety of foundations and trafficability of constructing vehicle in civil engineering. This research presents the comparative estimation of the actual and theoretical measurement on the underground stress of outer layer for each soil after the observation of each top soil layer fur its vertical and horizontal stresses in (1) homogeneous sand ground (2) weak stratum with the sand soil (3) weak stratum with gravel of the soil model, and it also investigates the effect of subsidence of ground by the repeated load. The underground stresses fumed out to be different in the value of theoretical and actual measurement after the trial examination of model. This study has the purpose of suggesting the better construction method of running equipment on weak stratum by comparing the estimated value of trial experiment and theory on underground stress of the weak ground surface area and of raising up the necessity of the continuous research hereafter.

축소모형실험을 이용한 연약대층 근접 터널의 거동 (Behavior of tunnel adjacent to weak zone by using scaled model test)

  • 이동석;전재현;박종덕;이석원
    • 한국터널지하공간학회 논문집
    • /
    • 제14권3호
    • /
    • pp.231-246
    • /
    • 2012
  • 최근 터널 건설은 종종 연약대층을 인접하여 계획하게 된다. 이러한 경우 터널 굴착은 안정화되어 있던 지반을 이완시키고 따라서 터널의 안정성에 문제를 일으킬 수 있다. 안정성에 문제를 일으킬 수 있는 주요 영향인자들을 보면 연약대층이 지표면과 이루는 각도, 연약대층과 터널의 이격거리 등을 들 수 있다. 본 연구에서는 연약대층을 인접하여 건설되는 터널의 굴착과정에서 발생하는 변위량과 균열발생 양상을 조사함으로써, 연약대층이 지표면과 이루는 각도 및 연약대층과 터널의 이격거리가 터널의 역학적 거동에 미치는 영향을 조사하였다. 연약대층이 지표면과 이루는 각도 및 연약대층과 터널의 이격거리를 변화시켜 가면서 균질한 재료를 가지고 실내 축소 모형실험을 수행하고 이를 분석하였다. 실험결과, 연약대층이 지표면과 이루는 각도가 수평에서 수직으로 변화함에 따라 터널 주변의 변위 발생량이 증가하였다. 연약대층과 터널의 이격거리가 증가함에 따라 터널 주변의 변위 발생량이 감소하였고, 특정 이격거리 이상에서 안정화되었다. 이러한 발견들은 기존의 연구결과들을 정량적으로 검증하고 확장하는 것이라 판단된다. 최종적으로 연약대층이 지표면과 이루는 각도 변화에 따른 연약대층과 터널의 적정 이격거리를 정의하였다. 이러한 기초적인 연구는 연약대층을 인접하여 신설되는 터널 설계에 보다 합리적인 제안을 할 수 있을 것으로 판단된다.

연약점토층위 이층지반 지표면 재하시 지중응력 특성연구 (A Study on the Stress Distribution beneath Loaded Ground Surface Area of Double Strata Ground on Soft Clay Layers)

  • 임종석;이인형
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.423-428
    • /
    • 2005
  • If the load of constructing vehicles during the construction work acts on the road or the ground surface on the soft ground, due to the excess stresses in soils the trafficability of the vehicles influences the constructing efficiency, constructing period and so on. Stress distribution in soils is the very important element to design and to solve the problems of settlement, safety of foundations and trafficability of constructing vehicle in civil engineering. This research represents the comparative estimation of the actual and theoretical measurement on the underground stress of outer layer for each soil after the observation of each top soil layer for its vertical and horizontal stress in (1)homogeneous sand ground (2) weak stratum with the sand soil (3) weak stratum with gravel of the soil model, and it also investigates the effect of subsidence of ground by the repeated load. The underground stress turn out to be different in the value of theoretical and actual measurement after the trial examination of model.

  • PDF

Seismic evaluation and upgrading of RC buildings with weak open ground stories

  • Antonopoulos, T.A.;Anagnostopoulos, S.A.
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.611-628
    • /
    • 2012
  • The inelastic earthquake response of existing, reinforced concrete buildings with an open ground story, designed according to the old Greek codes, is investigated before and after their seismic strengthening with steel braces restricted to the open ground stories. The seismic performance evaluation is based on Part 3 of Eurocode 8 for assessment and retrofitting of buildings. Three and five-story, symmetric and non-symmetric buildings are subjected to a set of seven pairs of synthetic accelerograms, compatible with the design spectrum, and conclusions are drawn regarding the effectiveness of the strengthening solutions. Seismic behavior of the selected models confirms results of previous work regarding the insufficient capacity of the open ground stories for design level earthquakes. It is also shown that strengthening only the weak ground story, a choice having the substantial advantage of low cost and continued usage of the building during its seismic retrofitting, can remove the inherent weakness without shifting the problem to the stories above and thus making such buildings at least as strong as those without a weak first story. This partial strengthening is possible for symmetric as well as eccentric buildings, in which torsion plays a further detrimental role.

Study on slope stability of waste dump with a weak layer using finite element limit analysis method

  • Chong Chen;Huayong Lv;Jianjian Zhao;Zhanbo Cheng;Huaiyuan Wang;Gao Xu
    • Structural Engineering and Mechanics
    • /
    • 제89권3호
    • /
    • pp.253-263
    • /
    • 2024
  • Slope stability is generally paid more attention to in slope protection works, especially for slope containing weak layers. Two indexes of safety factor and failure model are selected to perform slope stability. Moreover, the finite element limit analysis method comprehensively combines the advantage of the limit analysis method and the finite element method obtaining the upper and lower bounds of the safety factor and the failure mode under the slope stability limit state. In this study, taking a waste dump containing a weak layer as an engineering background, the finite element limit analysis method is adopted to explore the potential failure mode. Meanwhile, the sensitivity analysis of slope stability is performed on geometrical and geotechnical parameters of the waste dump. The results show that the failure mode of the waste dump slope is two wedges if the weak layer is located on the ground surface (Model A), while the slope can be observed as three wedges failure if the weak layer is below the ground surface (Model B). In addition, both failure modes are highly sensitive to the friction angle of the weak layer and the shear strength of waste disposal, and moderately sensitive to the heap height, the dip angle and cohesion of the weak layer, while the toe cutting has limited effect on the slope stability. Moreover, the sensitivity to the excavation of the ground depends on the location of the weak layer and failure mode.

항만구조물의 기초처리공법 중 수치 PROGRAM을 이용한 강제치환 예상 추정선에 관한 연구 (A Study on the Numerical Model for Predicting Depth of Replacement and Consolidation by Embankment on Weak Soil)

  • 이상화;이영재
    • 한국해양공학회지
    • /
    • 제14권3호
    • /
    • pp.61-65
    • /
    • 2000
  • The estimation of soil stabilization is of great importance concerning the construction of structures on weak soil. A typical model of soil stabilization is considered as replacement, which is based on ground at failure due to direct loading on weak soil. The calculation of the line of predicting settlement was carried out using RPL and DIKE programs. The DIKE program is showing a tendency to excel totally about this embankment of the seadike. Hereafter, This program will be contributed widely to the construction of offshore structures on weak soil.

  • PDF

관출구로부터 방출되는 약한 충격파에 관한 3 차원 수치해석 (3-Dimensional Computations of the Weak Shock Wave Discharged from the Exit of Duct)

  • 권용훈;신현동;김희동;이동훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1742-1747
    • /
    • 2003
  • When a shock wave is discharged from the exit of a duct, complicated flow is formed near the duct exit. The flow field is much more complicated under the ground effects or any other objects near the exit of a duct, such as the circumstance near the exit of the high-speed railway tunnel. The resulting flow is essentially three-dimensional unsteady with the effects of strong compressibility. In the current study, three-dimensional flow fields of the weak shock wave which is discharged from the exit of a duct are numerically investigated using a CFD method. Computations are performed for the weak shock wave in the range below 1.5. The results obtained show that the directivity and magnitude of the weak shock discharged strongly depend upon the Mach number of initial shock wave and are significantly influenced by the ground effects.

  • PDF

Development of the Damping Coefficients for Weak and Moderate Earthquake Ground Motions

  • Kim, Myeong-Han
    • 한국방재학회 논문집
    • /
    • 제8권5호
    • /
    • pp.1-6
    • /
    • 2008
  • 대부분의 내진설계기준에서는 설계지반운동을 정의하기 위해서 설계스펙트럼을 제시하고 있다. 기준에서 제시되는 설계스펙트럼은 일반적으로 5% 임계감쇠비에 대한 것이며, 이것은 일반적인 건축구조물에 적용할 수 있는 것이다. 에너지 소산장치나 면진 시스템의 적용이 점차 증가하고 있으며, 이러한 장치를 적용한 건축구조물의 내진해석을 위해서는 5% 임계감쇠비를 초과하는 설계스펙트럼이 필요하다. 5% 임계감쇠비에 대한 설계스펙트럼을 다른 임계감쇠비에 대한 설계스펙트럼으로 변환하기 위해서는 감쇠계수가 효과적으로 이용될 수 있다. 현재의 내진설계기준에서 제시하고 있는 감쇠계수는 강진자료를 바탕으로 제시된 것이다. 중진 및 약진은 강진과는 다른 특성을 가지므로, 이러한 감쇠계수가 중진 및 약진 지역에 적용하는 것은 충분한 검토가 필요할 것이다. 이 논문에서는 중진 및 약진자료를 이용한 감쇠계수를 제시하고, 현재 설계기준에서 제시하고 있는 감쇠계수와 비교하였다.

연약지반에서의 교대변위를 고려한 EPS공법의 적용사례 연구 (A Case Study on the Application of EPS Construction Method Considering Abutment Displacement in Soft Ground)

  • 강희준;오일록;채영수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.698-705
    • /
    • 2004
  • Application of structural load on soft ground can cause lateral movement as well as ground break due to pressing and shearing of ground. Especially, abutment supported by pile foundation can make pile deformed due to lateral movement of ground in order to have harmful effect on structure. According to the result of this study, it is required to consider disturbance of weak soil layer when using lateral movement countermeasure method by EPS construction method as a result of performing study on safety review and EPS construction method with respect to this based on site where lateral movement occurs due to backside soil filling load at bridge abutment installed on weak ground, and it is required to sufficiently consider soil reduction during design of EPS construction method due to lateral movement deformation of soft clay layer by losing ground horizontal resistance force due to plasticity of ground around pile as well as combination part damage with pile head and expansion foundation.

  • PDF